background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

EtherCAT Slave / DeviceNet Slave

 

 

Document code: MN67E10_ENG     Revision 1.000   Page 4 of 24

 

 

 

EXAMPLE OF CONNECTION: 

 

 

 

 

 

 

 

 

Содержание HD67E10-A1

Страница 1: ...com Product HD67E05 BACnet Master www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E07 CAN www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E09 DeviceNet Master...

Страница 2: ...24 RETURN POLICY 24 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own...

Страница 3: ...he device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and opera...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave DeviceNet Slave Document code MN67E10_ENG Revision 1 000 Page 4 of 24 EXAMPLE OF CONNECTION...

Страница 5: ...dustrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave DeviceNet Slave Document code MN67E10_ENG Revision 1 000 Page 5 of 24 CONNECTION SCHEME Figure 1 Connection scheme for HD67E10 A...

Страница 6: ...er Supply Two directional information between EtherCAT bus and DeviceNet bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F...

Страница 7: ...MN67E10_ENG Revision 1 000 Page 7 of 24 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumpti...

Страница 8: ...g on the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is us...

Страница 9: ...links quickly Boot state Blinks very slowly 0 5Hz update in progress 3 EtherCAT comm green It blinks when EtherCAT communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in...

Страница 10: ...the standard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them whil...

Страница 11: ...t be made using Connector8 of the HD67E10 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections...

Страница 12: ...hat runs with Windows called SW67E10 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present...

Страница 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT Slave DeviceNet Slave Converter in order to configure another device in the s...

Страница 14: ...ge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possibl...

Страница 15: ...AT Slave DeviceNet Slave Document code MN67E10_ENG Revision 1 000 Page 15 of 24 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insi...

Страница 16: ...he DeviceNet Master section are In the field ID Device the address for the DeviceNet Slave is defined In the field Baudrate the velocity of the DeviceNet Master bus is defined In the field Number Byte...

Страница 17: ...the EtherCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT varia...

Страница 18: ...field Lenght the dimension of the EtherCAT variable is defined In the field Name the name of the EtherCAT variable is defined In the field Position the starting address of the EtherCAT array where th...

Страница 19: ...thernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip...

Страница 20: ...the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to progr...

Страница 21: ...Electronic Devices ADFweb com S r l User Manual EtherCAT Slave DeviceNet Slave Document code MN67E10_ENG Revision 1 000 Page 21 of 24 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for H...

Страница 22: ...ombination of the following HD67E10 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67E10 EtherCAT Slave DeviceNet Slave Converter Order Co...

Страница 23: ...lection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the...

Страница 24: ...se do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Отзывы: