 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

OPC UA Server / Modbus TCP Slave 

 

Document code: MN67B30_ENG     Revision 1.000    Page 8 of 23

 

 

FUNCTION MODES: 
 

The device has got two functions mode depending of the position of the Dip1 of ‘Dip-Switch A’: 

 

The first, with Dip1 in Off position (factory setting), is used for the normal working of the device. 

 

The second, with Dip1 in On position, is used for upload the Project/Firmware. 

 
For the operations to follow for the updating (see ‘UPDATE DEVICE’ section). 
 
According to the functioning mode, the LEDs will have specifics functions (see ‘LEDS’ section). 
 
 

 

 

 
 

 

Содержание HD67B30-B2

Страница 1: ...D67B29 Modbus TCP Master www adfweb com Product HD67B31 Bacnet Master www adfweb com Product HD67B32 Bacnet Slave www adfweb com Product HD67B33 CAN www adfweb com Product HD67B34 CANopen www adfweb c...

Страница 2: ...ES AND TECHNICAL SUPPORT 23 RETURN POLICY 23 Pagina 2 di 23 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is...

Страница 3: ...rlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation...

Страница 4: ...tronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server Modbus TCP Slave Document code MN67B30_ENG Revision 1 000 Page 4 of 23 EXAMPLE...

Страница 5: ...eb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server Modbus TCP Slave Document code MN67B30_ENG Revision 1 000 Page 5 of 23 CONNECTION SCHEME Figure 1...

Страница 6: ...converter It allows the following characteristics Up to 1500 bytes in reading and 1500 bytes in writing Two directional information between Modbus TCP and OPC UA Mountable on 35mm Rail DIN Wide power...

Страница 7: ...Modbus TCP Slave Document code MN67B30_ENG Revision 1 000 Page 7 of 23 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin V...

Страница 8: ...e device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second wi...

Страница 9: ...nks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Modbus comm yellow Flashing Modbus request OFF No Modbus request Blinks quickly Boot state Blinks very slowly 0 5Hz update in progr...

Страница 10: ...NET The Ethernet connection must be made using Connector3 of HD67B30 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 no...

Страница 11: ...ter use the available software that runs with Windows called SW67B30 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last...

Страница 12: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable OPC UA Server Modbus TCP Slave Converter in order to c...

Страница 13: ...there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section...

Страница 14: ...0438 30 91 31 User Manual OPC UA Server Modbus TCP Slave Document code MN67B30_ENG Revision 1 000 Page 14 of 23 In the section Software Settings it is possible to enable disable some keyboard s comman...

Страница 15: ...Check Box field This feature is used for going out of the net In the field DNS the IP Address of the DNS server is defined This feature can be enabled or disabled pressing the Check Box field In the...

Страница 16: ...rs Fig 4 This section is used to define the list of OPC UA variables to read write The means of the checkboxes inside the table are In the field Type the data format of the OPC UA variable is defined...

Страница 17: ...Turn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations ar...

Страница 18: ...PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure th...

Страница 19: ...ytes Position 2 3 of internal array Input Register 2 04 Input Bytes Position 4 5 of internal array Input Register 749 04 Input Bytes Position 1498 1499 of internal array Data in writing Type Address F...

Страница 20: ...rl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server Modbus TCP Slave Document code MN67B30_ENG Revision 1 000 Page 20 of 23 Figure 7 Mechanical dimensions sc...

Страница 21: ...t number is formed by a valid combination of the following HD67B30 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67B30 OPC UA Server Mo...

Страница 22: ...pean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an appl...

Страница 23: ...sh to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information ab...

Отзывы: