background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l.           

User Manual 

KNX/ MQTT - Coverter

 

 

Document code: MN67947_ENG     Revision 1.000   Page 30 of 31

 

 

 

DISCLAIMER: 
 

All technical content within this document can be modified without notice. The content of the document is a under continual renewal. 
For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal 
conditions repairs are charged to the user. ADFweb.com S.r.l. will not be liable for accidental loss of use or inability to use this product, such 
as loss of business income. ADFweb.com S.r.l. shall not be liable for consequences of improper use. 
 
 

OTHER REGULATIONS AND STANDARDS: 
 

WEEE

 INFORMATION

 

Disposal  of  old  electrical  and  electronic  equipment  (as  in  the  European  Union  and  other  European  countries  with  separate 
collection systems). 

 

This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish. Instead, it 

should  be  taken  to  an  applicable  collection  point  for  the  recycling  of  electrical  and  electronic  equipment.  If  the  product  is  disposed 
correctly,  you  will  help  prevent  potential  negative  environmental  factors  and  impact  of  human  health,  which  could  otherwise  be 
caused  by  inappropriate  disposal.  The  recycling  of  materials  will  help  to  conserve  natural  resources.  For  more  information  about 
recycling this product, please contact your local city office, your household waste disposal service or the shop where you purchased 
the product. 
 
 

R

ESTRICTION OF 

H

AZARDOUS 

S

UBSTANCES DIRECTIVE

 

 

The  device  respects  the  2002/95/EC  Directive  on  the  restriction  of  the  use  of  certain  hazardous  substances  in  electrical 
and electronic equipment (commonly referred to as Restriction of Hazardous Substances Directive or RoHS). 

 
 

CE

 MARKING

 

 

The product conforms with the essential requirements of the applicable EC directives. 

 
 

 
 

Содержание HD67947-B2

Страница 1: ...ct HD67935 Modbus TCP Master www adfweb com Product HD67936 Modbus TCP Slave www adfweb com Product HD67937 BACnet Master www adfweb com Product HD67938 BACnet Slave www adfweb com Product HD67939 CAN...

Страница 2: ...ND TECHNICAL SUPPORT 31 RETURN POLICY 31 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to...

Страница 3: ...ce can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual KNX MQTT Coverter Document code MN67947_ENG Revision 1 000 Page 4 of 31 EXAMPLE OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual KNX MQTT Coverter Document code MN67947_ENG Revision 1 000 Page 5 of 31 CONNECTION SCHEME Figure 1 Connection scheme for HD67947 B2...

Страница 6: ...n between Ethernet and KNX Mountable on 35mm Rail DIN Wide power supply input range 18 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67947 softwar...

Страница 7: ...47_ENG Revision 1 000 Page 7 of 31 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at...

Страница 8: ...he position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for...

Страница 9: ...te Blinks very slowly 0 5Hz update in progress 2 KNX communication yellow Blinks when KNX communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 MQTT status y...

Страница 10: ...security to the heating monitoring to the conditioning to the hydric control and alarms to energy management and so on Characteristics Description TP1 256 Medium Shielded Twisted Pair Topology Linear...

Страница 11: ...munication The Ethernet connection must be made using Connector2 of HD67947 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the...

Страница 12: ...nverter use the available software that runs with Windows called SW67947 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Window...

Страница 13: ...configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable KNX MQTT Converter in order to configure another device in the same manner it is n...

Страница 14: ...language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to c...

Страница 15: ...KNX MQTT Coverter Document code MN67947_ENG Revision 1 000 Page 15 of 31 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the...

Страница 16: ...ION By Pressing the Set Communication button from the main window for SW67947 Fig 2 the window Set Communication appears Fig 3 The window is divided in different sections in order to define the differ...

Страница 17: ...d by the Server and the Client in case of missing ACK If unchecked the Server and the Client hold the last MQTT messages and in case of incorrect disconnection or missing ACK they try to send again th...

Страница 18: ...he server address is define by URL and not IP Address WI FI This section is used to define the general parameters of Wi Fi It is possible to defined the type of Wi Fi communication Access Point Client...

Страница 19: ...e channel for Wi Fi communication is defined The means of the fields for Client configuration are If the field Obtain an IP Address automatically is checked the converter gets the IP Address using DHC...

Страница 20: ...f enabled in the field Server Certificate the certificate from the Server is defined If the field Client Authentication is checked the authentication of the Client using TLS is enabled If enabled o in...

Страница 21: ...a to KNX MQTT PUBLISH The means of the fields are In the field Topic the MQTT topic is defined If the field Retained is defined the retained flag is enabled The MQTT server will hold the last topic pu...

Страница 22: ...n the field QoS the QoS level is defined In the field Data Type the type of data to use is defined In the field Dimension the dimension in byte of the data is defined In the field Position the startin...

Страница 23: ...lowing o Read it is used to send a reading request to a KNX device o Write it is used to send a writing request to a KNX device o Specific value edited manually In the field Priority the Priority of t...

Страница 24: ...data read In the field Lenght the dimension of the KNX message is defined In the field Mnemonic the description for the request is defined Note If the field On change is checked and the Poll Time is d...

Страница 25: ...t cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of D...

Страница 26: ...restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you hav...

Страница 27: ...is necessary in order to define the structure of the payload of the MQTT message and the info contained It is possible to have a simple text format or a JSON format The definition of the template can...

Страница 28: ...ustrial Electronic Devices ADFweb com S r l User Manual KNX MQTT Coverter Document code MN67947_ENG Revision 1 000 Page 28 of 31 Figure 8 Mechanical dimensions scheme for HD67947 B2 MECHANICAL DIMENSI...

Страница 29: ...d by a valid combination of the following HD67947 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67947 KNX MQTT Converter Order Code HD6...

Страница 30: ...systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycli...

Страница 31: ...the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to th...

Отзывы: