SET COMMUNICATION:

 

 

 

By Pressing the “

Set Communication

” button from the main window for SW67938 

(Fig. 2) the window “Set Communication” appears (Fig. 3). 
 
The  window  is  divided  in  different  sections  in  order  to  define  the  different 
parameters of the converter: 

 

BACnet Slave 

 

MQTT 

 

Ethernet 

 

Wi-Fi 

 

TLS (Transport Layer Security) 

 

NTP (Network Time Protocol) 

 
 

Figure 3a: “Set Communication” window 

Содержание HD67938-IP-B2

Страница 1: ...7934 Modbus Slave www adfweb com Product HD67935 Modbus TCP Master www adfweb com Product HD67936 Modbus TCP Slave www adfweb com Product HD67937 BACnet Master www adfweb com Product HD67939 CAN www a...

Страница 2: ...33 WARRANTIES AND TECHNICAL SUPPORT 34 RETURN POLICY 34 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Upda...

Страница 3: ...ce can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Slave MQTT Document code MN67938_ENG Revision 1 000 Page 4 of 34 EXAMPLE OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Slave MQTT Document code MN67938_ENG Revision 1 000 Page 5 of 34 CONNECTION SCHEME Figure 1a Connection scheme for HD67938 IP B2...

Страница 6: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Slave MQTT Document code MN67938_ENG Revision 1 000 Page 6 of 34 Figure 1b Connection scheme for HD67938 MSTP B2...

Страница 7: ...s Mountable on 35mm Rail DIN Wide power supply input range 18 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67938 software on your PC in order to...

Страница 8: ...ion 1 000 Page 8 of 34 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC Devi...

Страница 9: ...he position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for...

Страница 10: ...Blinks very slowly 0 5Hz update in progress 2 BACnet communication yellow Blinks when BACnet communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 MQTT stat...

Страница 11: ...put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belde...

Страница 12: ...IP communication The Ethernet connection must be made using Connector2 of HD67938 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform...

Страница 13: ...nverter use the available software that runs with Windows called SW67938 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Window...

Страница 14: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable BACnet Slave MQTT Converter in order to configure another device in the same manner it...

Страница 15: ...language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to c...

Страница 16: ...BACnet Slave MQTT Document code MN67938_ENG Revision 1 000 Page 16 of 34 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the...

Страница 17: ...By Pressing the Set Communication button from the main window for SW67938 Fig 2 the window Set Communication appears Fig 3 The window is divided in different sections in order to define the different...

Страница 18: ...e converter is defined In the fields GATEWAY the default gateway of the network is defined This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of th...

Страница 19: ...Device Name the name to give to the BACnet node is defined In the field MAC Address the MAC of BACnet node from 0 to 254 is defined The field Max Master specifies the highest allowable address for ma...

Страница 20: ...incorrect disconnection or missing ACK they try to send again them since all the ACK messages are exchanged correctly valid only for QoS 1 and QoS 2 If the field Will Flag is checked the converter wi...

Страница 21: ...IP Address WI FI This section is used to define the general parameters of Wi Fi It is possible to defined the type of Wi Fi communication Access Point Client The means of the fields for Access Point c...

Страница 22: ...ed The means of the fields for Client configuration are If the field Obtain an IP Address automatically is checked the converter gets the IP Address using DHCP Otherwise the IP Address is defined as s...

Страница 23: ...f enabled in the field Server Certificate the certificate from the Server is defined If the field Client Authentication is checked the authentication of the Client using TLS is enabled If enabled o in...

Страница 24: ...a to BACnet MQTT PUBLISH The means of the fields are In the field Topic the MQTT topic is defined If the field Retained is defined the retained flag is enabled The MQTT server will hold the last topic...

Страница 25: ...n the field QoS the QoS level is defined In the field Data Type the type of data to use is defined In the field Dimension the dimension in byte of the data is defined In the field Position the startin...

Страница 26: ...ains the BACnet objects writeable by a BACnet Master the MQTT messages published The meaning of the fields in the window are the follows In the field Data Type is possible to select the BACnet object...

Страница 27: ...ling the Selected BACnet Engineering Unit field or by selecting with the fields Select the Type and Select unit the Type Unit desired If the second way is used is necessary to press the Select Enginee...

Страница 28: ...t cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of D...

Страница 29: ...restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you hav...

Страница 30: ...necessary in order to define the structure of the payload of the MQTT message and the info contained It is possible to have a simple text format or a JSON format The definition of the template can be...

Страница 31: ...trial Electronic Devices ADFweb com S r l User Manual BACnet Slave MQTT Document code MN67938_ENG Revision 1 000 Page 31 of 34 Figure 9 Mechanical dimensions scheme for HD67938 xxx B2 MECHANICAL DIMEN...

Страница 32: ...rs Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 2M 35mm DIN Rail mounting BACnet Type IP BACnet IP MSTP BACnet MS TP Device Family HD67938 BACnet Slave MQTT Converter Order Code HD67938 IP B2...

Страница 33: ...systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycli...

Страница 34: ...the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to th...

Отзывы: