Document code: MN67901_ENG     Revision 1.000   Page 1 of 35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.001 
English

 

 

BAcnet Slave / HART Master - Converter

  

(Order Code:  HD67901-IP-A1, HD67901-MSTP-A1) 

 

For Website information:  

www.adfweb.com?Product=HD67901

   

 

For Price information: 

www.adfweb.com?Price=HD67901-IP-A1

  

www.adfweb.com?Price=HD67901-MSTP-A1

  

 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple Electrical isolation 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

For other HART products see also the following link: 

 

Converter HART Master to  

www.adfweb.com?Product=HD67900

      

(Serial) 

www.adfweb.com?Product=HD67902

      

(CAN) 

www.adfweb.com?Product=HD67903

       

(CANopen) 

www.adfweb.com?Product=HD67904

       

(DeviceNet Slave) 

www.adfweb.com?Product=HD67905

      

(Ethernet) 

www.adfweb.com?Product=HD67906

      

(EtherNet/IP Slave) 

www.adfweb.com?Product=HD67907

      

(J1939) 

www.adfweb.com?Product=HD67908

       

(Modbus Slave) 

www.adfweb.com?Product=HD67909

       

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67910

      

(MQTT) 

www.adfweb.com?Product=HD67911

       

(PROFIBUS Slave) 

www.adfweb.com?Product=HD67912

       

(PROFINET Slave) 

www.adfweb.com?Product=HD67913

      

(SNMP Agent) 

 

 
Do you have your customer protocol? Then go to: 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? Do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Содержание HD67901-IP-A1

Страница 1: ...following link Converter HART Master to www adfweb com Product HD67900 Serial www adfweb com Product HD67902 CAN www adfweb com Product HD67903 CANopen www adfweb com Product HD67904 DeviceNet Slave...

Страница 2: ...ARDS 34 WARRANTIES AND TECHNICAL SUPPORT 35 RETURN POLICY 35 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is...

Страница 3: ...device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operatio...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Slave HART Master Document code MN67901_ENG Revision 1 000 Page 4 of 35 EXAMPLES OF CONNECTION...

Страница 5: ...ndustrial Electronic Devices ADFweb com S r l User Manual BACnet Slave HART Master Document code MN67901_ENG Revision 1 000 Page 5 of 35 CONNECTION SCHEME Figure 1a Connection scheme for HD67901 IP A1...

Страница 6: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Slave HART Master Document code MN67901_ENG Revision 1 000 Page 6 of 35 Figure 1a Connection scheme for HD67901 MSTP A1...

Страница 7: ...ation between BACnet Power Supply BACnet HART HART Power Supply Two directional information between BACnet bus and HART bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V...

Страница 8: ...ENG Revision 1 000 Page 8 of 35 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24...

Страница 9: ...with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the op...

Страница 10: ...vice State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 HART communication green It blinks when HART communication is running Blinks quickly Boot sta...

Страница 11: ...gnals at a low level on top of the 4 20mA This enables two way field communication to take place and makes it possible for additional information beyond just the normal process variable to be communic...

Страница 12: ...ation must be made using Connector4 of the HD67901 XXXX A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative...

Страница 13: ...ry to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield...

Страница 14: ...runs with Windows called SW67901 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on...

Страница 15: ...configuration A device s configuration can also be imported or exported To clone the configurations of a programmable BACnet Slave HART Master in order to configure another device in the same manner...

Страница 16: ...the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible t...

Страница 17: ...net Slave HART Master Document code MN67901_ENG Revision 1 000 Page 17 of 35 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside...

Страница 18: ...ing response from HART device is defined If selected BACnet IP the means of the fields for BACnet are In the fields IP ADDRESS the IP address of BACnet IP side of the converter is defined In the field...

Страница 19: ...defined The field Max Master specifies the highest allowable address for master nodes The value shall be less than or equal to 127 The field Max Info Frames specifies the maximum number of informatio...

Страница 20: ...es to read write with the BACnet Master The means of the fields are If the field Enable is checked the HART variable is enabled In the field Device Address the address of HART device is defined In the...

Страница 21: ...the HART data is defined In the field Swap the bytes order is reversed In the field Conv Int the data from HART device is converted in Integer format In the field Operations a post operation on the da...

Страница 22: ...ains the BACnet objects writeable by a BACnet Master HART data written The meaning of the fields in the window are the follows In the field Data Type is possible to select the BACnet object data type...

Страница 23: ...compiling the Selected BACnet Engineering Unit field or by selecting with the fields Select the Type and Select unit the Type Unit desired If the second way is used is necessary to press the Select En...

Страница 24: ...rnet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 o...

Страница 25: ...program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program...

Страница 26: ...riables section It has the following characteristics Possibility to scan HART network Automatic decode of HART messages Easy connection directly through the Ethernet port of the converter In order to...

Страница 27: ...s configured in the converter Start the Scan by clicking on Start Scan button The window will appear like below When the Scan is complete the software will show the results You can import the data by...

Страница 28: ...like Internet Explorer Google Chrome Mozilla Firefox by editing the IP Address of the converter in the address bar of the browser WELCOME As soon as the connection to the Webserver interface of the Da...

Страница 29: ...ave HART Master Document code MN67901_ENG Revision 1 000 Page 29 of 35 When one of the buttons of the Welcome page are pressed it is necessary to do the login using the Admin and Password defined in t...

Страница 30: ...an button is pressed the HART Scan window appears Fig 12 It has the following fields NUMBER OF DEVICES TO SEARCH FOR Maximum 16 field number of Hart devices connected Scan Start button it is possible...

Страница 31: ...discovered HART node from HART Scan section is selected the HART Control window appears Fig 13 It has the following fields UNIQUE ID button it is possible to insert the unique ID of the HART device t...

Страница 32: ...Electronic Devices ADFweb com S r l User Manual BACnet Slave HART Master Document code MN67901_ENG Revision 1 000 Page 32 of 35 MECHANICAL DIMENSIONS Figure 14 Mechanical dimensions scheme for HD6790...

Страница 33: ...e 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting BACnet type IP BACnet IP MSTP BACnet MS TP Device Family HD67901 BACnet Slave HART Master Converter Order Code HD67901 IP A1...

Страница 34: ...tion systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the rec...

Страница 35: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to...

Отзывы: