background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

DALI / Serial - Converter

 

 

Document code: MN67831_ENG     Revision 1.100   Pagina 1 di 56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.100 
English 

 

DALI / RS485 - Converter 

 (Order Code:  HD67831-2-B2-Y, HD67831-2-B2-N, 
HD67831-4-B2-Y, HD67831-4-B2-N) 

 
for Website information:  

www.adfweb.com?Product=HD67831

  

 

for Price information: 

www.adfweb.com?Price=HD67831-2-B2

  

www.adfweb.com?Price=HD67831-4-B2

  

 
 

Benefits and Main Features: 

 

Very easy to configure 

 

Electrical isolation 

 

Temperature range: -40°C/85°C (-40°F/185°F) 

For others DALI products, see also the following links: 

 

Converter DALI to  

www.adfweb.com?Product=HD67822

      

(KNX) 

www.adfweb.com?Product=HD67832

      

(BACnet/IP Master) 

www.adfweb.com?Product=HD67833

       

(BACnet/IP Slave) 

www.adfweb.com?Product=HD67834

      

(CAN) 

www.adfweb.com?Product=HD67835

      

(CANopen) 

www.adfweb.com?Product=HD67836

       

(DeviceNet Master) 

www.adfweb.com?Product=HD67837

       

(DeviceNet Slave) 

www.adfweb.com?Product=HD67838

       

(DMX) 

www.adfweb.com?Product=HD67839

      

(Ethernet) 

www.adfweb.com?Product=HD67840

      

(EtherNet/IP) 

www.adfweb.com?Product=HD67842

      

(Modbus Master) 

www.adfweb.com?Product=HD67843

      

(Modbus Slave) 

www.adfweb.com?Product=HD67844

      

(Modbus TCP Master) 

www.adfweb.com?Product=HD67845

      

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67848

       

(PROFINET) 

www.adfweb.com?Product=HD67849

      

(SNMP Manager) 

www.adfweb.com?Product=HD67850

      

(SNMP Agent) 

www.adfweb.com?Product=HD67941

      

(MQTT) 

 

 

Do you have an your customer protocol? 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Содержание HD67831-2-B2-N

Страница 1: ...NX www adfweb com Product HD67832 BACnet IP Master www adfweb com Product HD67833 BACnet IP Slave www adfweb com Product HD67834 CAN www adfweb com Product HD67835 CANopen www adfweb com Product HD678...

Страница 2: ...ISCLAIMER 55 OTHER REGULATIONS AND STANDARDS 55 WARRANTIES AND TECHNICAL SUPPORT 56 RETURN POLICY 56 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need...

Страница 3: ...ks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation asse...

Страница 4: ...Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DALI Serial Converter Document code MN67831_ENG Revision 1 100 Pagina 4 di 56 EXAMPLE OF...

Страница 5: ...Fweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DALI Serial Converter Document code MN67831_ENG Revision 1 100 Pagina 5 di 56 CONNECTION SCHEME Figure 1a Con...

Страница 6: ...evices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DALI Serial Converter Document code MN67831_ENG Revision 1 100 Pagina 6 di 56 Figure 1b Connection s...

Страница 7: ...l Power Supply Serial Additional isolation Power Supply DALI for HD67831 x B2 N version Two directional information between DALI bus and Serial bus Mountable on 35mm Rail DIN Wide power supply input r...

Страница 8: ...l Converter Document code MN67831_ENG Revision 1 100 Pagina 8 di 56 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin V...

Страница 9: ...t two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip...

Страница 10: ...1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 DALI communication yellow Blinks when DALI communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz upda...

Страница 11: ...ng the lighting system from a simple light switch to lighting management systems for entire office complexes with thousands of light sources Using ADFweb com s DALI converters any light source includi...

Страница 12: ...l DALI Serial Converter Document code MN67831_ENG Revision 1 100 Pagina 12 di 56 RS232 The connection from RS232 socket to a serial port example one from a personal computer must be made with a NULL M...

Страница 13: ...istor it is necessary to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil...

Страница 14: ...ing DALI network and for programming the device The Ethernet connection must be made using Connector2 of HD67831 x B2 with at least a Category 5E cable The maximum length of the cable should not excee...

Страница 15: ...use the available software that runs with Windows called SW67831 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last ve...

Страница 16: ...hich contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable DALI Serial Converter in order to configure anot...

Страница 17: ...re is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Con...

Страница 18: ...39 0438 30 91 31 User Manual DALI Serial Converter Document code MN67831_ENG Revision 1 100 Pagina 18 di 56 In the section Software Settings it is possible to enable disable some keyboard s commands f...

Страница 19: ...ed In the field Parity the parity of the serial line is defined In the field ID Board the ID of the converter is defined The means of the fields for the DALI section are In the field DALI Console Port...

Страница 20: ...ears Fig 4 This section is composed by three tables used to define the list of DALI devices to control the DALI sensors to read and the DALI router s functions SELECT DEVICE The Select Device section...

Страница 21: ...send to the DALI ballasts The means of the fields are If the field Enable is checked the DALI device sensor is enabled In the field Dev Sen the DALI node is defined In the field Type the type of DALI...

Страница 22: ...6 In the field Position the byte of the internal memory array where mapping the data is defined In the field Num Bytes the dimension of the data is defined In the field Mnemonic a description of the r...

Страница 23: ...exc like a DALI router The means of the fields are In the field Function the DALI operation to execute is defined In the field Condition the logic operation to apply on the data is defined In the fie...

Страница 24: ...the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK clo...

Страница 25: ...pdating Try with another PC Try to restart the PC Check the LAN settings Check the Wi Fi settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you a...

Страница 26: ...nd test the communication it is possible to use the available software that runs with Windows called DALI Console It is downloadable on the site www adfweb com and its operation is described in this d...

Страница 27: ...e DALI network and program automatically the IDs Search menu export import the results of the communication Dali File menu see the informations about the DALI Console software About menu and test DALI...

Страница 28: ...In the field DEVICE PORT the communication port is defined It is fixed to 10000 In the field CONSOLE PORT the communication port for the DALI commands is defined It is the one defined in the field DA...

Страница 29: ...earch this function will scan and address only the DALI devices without ID Full Sensor Search this function will scan and address all the DALI sensors Partial Sensor Search this function will scan and...

Страница 30: ...age and test the functioning of the network DEVICES The means of the fields for DEVICE INFO are In the field Device Type the type of DALI device is printed In the field Software version the software v...

Страница 31: ...Maximum ADV value In the GROUP MEMBERSHIP section it is possible to see the Groups which the selected DALI device is in The checked checkboxes mean that the device is in the correspondent groups the u...

Страница 32: ...In the fields SENSOR STATUS the actual status of the DALI sensor is printed In the field SET NEW ADDRESS it is possible to program a new ID to the DALI sensor In the field REMOVE ADDRESS it is possib...

Страница 33: ...ALI group For set commands it is possible to insert the value to set in the field xx As soon as the command to send is selected the command is sent in order to send the same command more times it is p...

Страница 34: ...ual DALI Serial Converter Document code MN67831_ENG Revision 1 100 Pagina 34 di 56 SCENES By selecting a DALI scene from the Network view it is possible to see the devices that have programmed the sel...

Страница 35: ...ommands it is possible to insert the value to set in the field xx As soon as the command to send is selected the command is sent in order to send the same command more times it is possible to press th...

Страница 36: ...the data from to DALI side it is necessary to send simple ASCII commands GETTING DATA FROM DALI NODE This command is used to read a specific DALI node in the network REQUEST I_BAL_ch_00 ASCII format W...

Страница 37: ...groups set inside the DALI device from 8 to 15 scn scenes programmed inside the DALI device 1 byte for each scene total of 16 bytes Note Just ch val typ rs min max g1 g2 and scn are variable the rest...

Страница 38: ...node in the network REQUEST S_BAL_ch_val ASCII format Where ch ID of the DALI ballast to read 0 63 val value of the ADV to set 0 FF Hex representation Note Just ch and val are variable the rest of th...

Страница 39: ...oup in the network REQUEST S_GRP_ch_val ASCII format Where ch ID of the DALI group to read 0 15 val value of the ADV to set 0 FF Hex representation Note Just ch and val are variable the rest of the AS...

Страница 40: ...ic ADV value into a the entire DALI network broadcast REQUEST S_BRD_00_val ASCII format Where val value of the ADV to set 0 FF Hex representation Note Just val is variable the rest of the ASCII string...

Страница 41: ...roup or broadcast REQUEST S_SCE_sc_id ASCII format Where sc scene to activate 0 15 id ID of the DALI node 0 63 or group 64 79 or broadcast 80 Note Just sc and id are variable the rest of the ASCII str...

Страница 42: ...ces REQUEST S_MAX_id_val ASCII format Where id ID of the DALI node 0 63 or group 64 79 or broadcast 80 val value of new max value to set 0 FF Hex representation Note Just id and val are variables the...

Страница 43: ...ces REQUEST S_MIN_id_val ASCII format Where id ID of the DALI node 0 63 or group 64 79 or broadcast 80 val value of new min value to set 0 FF Hex representation Note Just id and val are variables the...

Страница 44: ...EST S_PON_id_val ASCII format Where id ID of the DALI node 0 63 or group 64 79 or broadcast 80 val value of new power ON value to set 0 FF Hex representation Note Just id and val are variables the res...

Страница 45: ...EQUEST S_FAI_id_val ASCII format Where id ID of the DALI node 0 63 or group 64 79 or broadcast 80 val value of new Fail Power value to set 0 FF Hex representation Note Just id and val are variables th...

Страница 46: ...QUEST S_RAT_id_val ASCII format Where id ID of the DALI node 0 63 or group 64 79 or broadcast 80 val value of new Fade Rate value to set 0 FF Hex representation Note Just id and val are variables the...

Страница 47: ...QUEST S_TIM_id_val ASCII format Where id ID of the DALI node 0 63 or group 64 79 or broadcast 80 val value of new Fade Time value to set 0 FF Hex representation Note Just id and val are variables the...

Страница 48: ...k The converter will remove all the addresses from the DALI devices and reprogram them like Full Search on DALI Console software REQUEST S_FULL_1 ASCII format RESPONSE FULL DEVICES SEARCH STARTED ASCI...

Страница 49: ...ork The converter search for new DALI devices without addressing and programming them like Partial Search on DALI Console software REQUEST S_PARZ_1 ASCII format RESPONSE PARTIAL DEVICES SEARCH STARTED...

Страница 50: ...etwork The converter will remove all the addresses from the DALI sensors and reprogram them like Full Sensor Search on DALI Console software REQUEST S_FULL_2 ASCII format RESPONSE FULL SENSORS SEARCH...

Страница 51: ...network The converter search for new DALI sensors without addressing and programming them like Partial Sensor Search on DALI Console software REQUEST S_PARZ_2 ASCII format RESPONSE PARTIAL SENSORS SE...

Страница 52: ...the converter is still searching or if it is finished REQUEST S_TEST_SEARCH ASCII format RESPONSE SEARCH STATUS X 0 finished now N devices found ASCII format Where X Status 0 means that the operation...

Страница 53: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual DALI Serial Converter Document code MN67831_ENG Revision 1 100 Pagina 53 di 56 MECHANICAL DIMENSIONS Figure 15 Mechani...

Страница 54: ...s Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 2M 35mm DIN Rail mounting Serial type 2 RS232 4 RS485 Device Family HD67831 DALI Serial Converter Order Code HD67831 2 B2 Y DALI RS232 Con...

Страница 55: ...countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicab...

Страница 56: ...to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about...

Отзывы: