background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l.           

User Manual 

EtherNet/IP Master / KNX - Converter

 

 

Document code: MN67806_ENG     Revision 1.000   Page 1 of 25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English 

 

EtherNet/IP Master / KNX- Converter 

 (Order Code:  HD67806-KNX-B2) 

 
 

For Website information:  

www.adfweb.com?Product=HD67806-B2

  

 

For Price information: 

www.adfweb.com?Price=HD67806-KNX-B2

 

 

 

Benefits and Main Features: 

 

Very easy to configure 

 

Power Supply 18…35V DC and 8…24 V AC 

 

Temperature range: -40°C/+85°C  (-40°F/+185°F) 

For others KNX products, see also the following links: 

 

Converter KNX to  

www.adfweb.com?Product=HD67746

      

(IEC 61850 Server) 

www.adfweb.com?Product=HD67773

      

(IEC 61850 Client) 

www.adfweb.com?Product=HD67801

      

(BACnet Master)

 

www.adfweb.com?Product=HD67802

      

(BACnet Slave) 

www.adfweb.com?Product=HD67803

       

(CAN) 

www.adfweb.com?Product=HD67804

      

(CANopen) 

www.adfweb.com?Product=HD67807

      

(EtherNet/IP Slave) 

www.adfweb.com?Product=HD67808

      

(DeviceNet Master) 

www.adfweb.com?Product=HD67809

      

(DeviceNet Slave) 

www.adfweb.com?Product=HD67810

      

(J1939) 

www.adfweb.com?Product=HD67811

       

(M-Bus Master/wM-Bus) 

www.adfweb.com?Product=HD67812

        

(Modbus Master) 

www.adfweb.com?Product=HD67813

      

(Modbus Slave)

 

www.adfweb.com?Product=HD67814

       

(Modbus TCP Master)

 

www.adfweb.com?Product=HD67815

       

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67818

       

(PROFINET slave) 

www.adfweb.com?Product=HD67820

       

(SNMP) 

www.adfweb.com?Product=HD67821

       

(DMX) 

www.adfweb.com?Product=HD67822

       

(DALI) 

www.adfweb.com?Product=HD67825

       

(Ethernet) 

www.adfweb.com?Product=HD67830

       

(NMEA 2000) 

www.adfweb.com?Product=HD67947

      

(MQTT) 

www.adfweb.com?Product=HD67B18

      

(OPC UA Client) 

www.adfweb.com?Product=HD67B41

      

(OPC UA Server) 

www.adfweb.com?Product=HD67B79

      

(PROFINET Master) 

 

 

Do you have an your customer protocol? 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? do you want help? 

www.adfweb.com?Cmd=helpme

 

User Manual   

 

Содержание HD67806-KNX-B2

Страница 1: ...HD67804 CANopen www adfweb com Product HD67807 EtherNet IP Slave www adfweb com Product HD67808 DeviceNet Master www adfweb com Product HD67809 DeviceNet Slave www adfweb com Product HD67810 J1939 www...

Страница 2: ...SUPPORT 25 RETURN POLICY 25 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product y...

Страница 3: ...The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and oper...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherNet IP Master KNX Converter Document code MN67806_ENG Revision 1 000 Page 4 of 25 EXAMPLE OF CONNECTION...

Страница 5: ...trial Electronic Devices ADFweb com S r l User Manual EtherNet IP Master KNX Converter Document code MN67806_ENG Revision 1 000 Page 5 of 25 CONNECTION SCHEME Figure 1 Connection scheme for HD67806 KN...

Страница 6: ...rical isolation between Ethernet and KNX Mountable on 35mm Rail DIN Wide power supply input range 18 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor S...

Страница 7: ...67806_ENG Revision 1 000 Page 7 of 25 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption...

Страница 8: ...ing of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is...

Страница 9: ...links slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 EtherNet IP communication yellow Blinks when EtherNet IP communication is running Blinks quickly Boot state Bli...

Страница 10: ...to the security to the heating monitoring to the conditioning to the hydric control and alarms to energy management and so on Characteristics Description TP1 256 Medium Shielded Twisted Pair Topology...

Страница 11: ...et IP communication The Ethernet connection must be made using Connector2 of HD67806 KNX B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to co...

Страница 12: ...e the Converter use the available software that runs with Windows called SW67806 It is downloadable on the site www adfweb com and its operation is described in this document The software works with M...

Страница 13: ...configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable EtherNet IP Master KNX Converter in order to configure another device in the same...

Страница 14: ...ange the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possi...

Страница 15: ...t IP Master KNX Converter Document code MN67806_ENG Revision 1 000 Page 15 of 25 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation ins...

Страница 16: ...s defined fixed to KNX TP In the field ID Device the ID of the KNX side of the converter is defined The means of the fields for EtherNet IP Master are In the fields IP ADDRESS the IP address for Ether...

Страница 17: ...array is defined In the field Num Input the number of consecutive Input byte to map on internal memory array is defined In the field Start Output the starting Output byte of the EtherNet IP slave to...

Страница 18: ...ssage is defined You can choose between the following o Read it is used to send a reading request to a KNX device o Write it is used to send a writing request to a KNX device o Specific value edited m...

Страница 19: ...byte of the field Position where start to insert the data read In the field Lenght the dimension of the KNX message is defined In the field Mnemonic the description for the request is defined Note If...

Страница 20: ...Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Di...

Страница 21: ...the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator p...

Страница 22: ...ectronic Devices ADFweb com S r l User Manual EtherNet IP Master KNX Converter Document code MN67806_ENG Revision 1 000 Page 22 of 25 Figure 8 Mechanical dimensions scheme for HD67806 KNX B2 MECHANICA...

Страница 23: ...id combination of the following HD67806 KNX B 2 Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 4M 35mm DIN Rail mounting Device Family HD67806 KNX EtherNet IP Master KNX Converter Order C...

Страница 24: ...llection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the...

Страница 25: ...ase do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the produc...

Отзывы: