background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

CAN / KNX

 

 

Document code: MN67803_ENG     Revision 1.002   Pagina 1 di 28

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

User Manual 

Revision 1.002 
English 

 

CAN / KNX - Converter 

 (Order Code:  HD67803-KNX-B2) 

 
for Website information:  

www.adfweb.com?Product=HD67803

 

 

for Price information: 

www.adfweb.com?Price=HD67803-KNX-B2

  

 
 

Benefits and Main Features: 

 

Very easy to configure 

 

Electrical isolation 

 

Temperature range: -40°C/85°C (-40°F/185°F) 

 

For others KNX products, see also the following links: 

 

Converter KNX to  

www.adfweb.com?Product=HD67801

      

(BACnet Master)

 

www.adfweb.com?Product=HD67802

      

(BACnet Slave) 

www.adfweb.com?Product=HD67804

      

(CANopen) 

www.adfweb.com?Product=HD67807

      

(EtherNet/IP) 

www.adfweb.com?Product=HD67808

      

(DeviceNet Master) 

www.adfweb.com?Product=HD67809

      

(DeviceNet Slave) 

www.adfweb.com?Product=HD67810

      

(J1939) 

www.adfweb.com?Product=HD67811

       

(M-Bus Master/wM-Bus) 

www.adfweb.com?Product=HD67812

        

(Modbus Master) 

www.adfweb.com?Product=HD67813

      

(Modbus Slave)

 

www.adfweb.com?Product=HD67814

       

(Modbus TCP Master)

 

www.adfweb.com?Product=HD67815

       

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67818

       

(PROFINET) 

www.adfweb.com?Product=HD67820

       

(SNMP) 

www.adfweb.com?Product=HD67821

       

(DMX) 

www.adfweb.com?Product=HD67825

       

(Ethernet) 

 

 

Do you have an your customer protocol? 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Содержание HD67803-KNX-B2

Страница 1: ...r www adfweb com Product HD67802 BACnet Slave www adfweb com Product HD67804 CANopen www adfweb com Product HD67807 EtherNet IP www adfweb com Product HD67808 DeviceNet Master www adfweb com Product H...

Страница 2: ...T 28 RETURN POLICY 28 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own...

Страница 3: ...QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly co...

Страница 4: ...strial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN KNX Document code MN67803_ENG Revision 1 002 Pagina 4 di 28 EXAMPLE OF CONNEC...

Страница 5: ...ices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN KNX Document code MN67803_ENG Revision 1 002 Pagina 5 di 28 CONNECTION SCHEME Figure 1 Connection...

Страница 6: ...rectional information between KNX bus and CAN bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Comp...

Страница 7: ...NX Document code MN67803_ENG Revision 1 002 Pagina 7 di 28 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24...

Страница 8: ...unctions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch...

Страница 9: ...in progress 2 CAN communication yellow Blinks when CAN frame is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 KNX communication yellow Blinks when KNX frame is recei...

Страница 10: ...on 1 002 Pagina 10 di 28 CAN For terminate the CAN line with a 120 resistor it is necessary that the Dip1 of Dip Switch C is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC par...

Страница 11: ...ng to control dampers to the security to the heating monitoring to the conditioning to the hydric control and alarms to energy management and so on Characteristics Description TP1 256 Medium Shielded...

Страница 12: ...used for programming the device The Ethernet connection must be made using Connector2 of HD67803 KNX B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The ca...

Страница 13: ...e available software that runs with Windows called SW67803 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version o...

Страница 14: ...contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable CAN KNX Converter in order to configure another devic...

Страница 15: ...he possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection...

Страница 16: ...other for Ethernet The means of the fields for KNX are In the field Type the type of KNX is defined fixd to KNX TP In the field ID Device the ID of the KNX side of the converter is defined The means o...

Страница 17: ...ated by In the field APCI the APCI of the KNX message is defined You can choose between the following o Read it is used to send a reading request to a KNX device o Write it is used to send a writing r...

Страница 18: ...e information In the field Bit Mode insert the start bit of the first byte of the field Position where start to insert the data read In the field Length the dimension of the KNX message is defined In...

Страница 19: ...the COB from 1 to 8 The field TimeOut is used for put at zero the data into KNX if the CAN frame don t arrives with a frequency less than the time expressed in the field If the value in the field is 0...

Страница 20: ...CAN KNX Document code MN67803_ENG Revision 1 002 Pagina 20 di 28 In the field Byte7 insert the address of the KNX array where saving 7th byte of the CAN message In the field Byte8 insert the address o...

Страница 21: ...t the number of byte of the COB from 1 to 8 If the field OnChange is checked the frame is sent when the data from KNX change If the field OnTimer is checked the frame is sent cyclically with the delay...

Страница 22: ...CAN KNX Document code MN67803_ENG Revision 1 002 Pagina 22 di 28 In the field Byte7 insert the address of the KNX array where taking 7th byte of the CAN message In the field Byte8 insert the address o...

Страница 23: ...Device Found must appear Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device P...

Страница 24: ...Try with another PC Try to restart the PC Check the LAN settings Check the Wi Fi settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are usin...

Страница 25: ...web com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN KNX Document code MN67803_ENG Revision 1 002 Pagina 25 di 28 MECHANICAL DIMENSIONS Figure 9 Mechanical dim...

Страница 26: ...HD67803 KNX B 2 Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 4M 35mm DIN Rail mounting Device Family HD67803 KNX CAN KNX Converter Order Code HD67803 KNX B2 CAN KNX Converter ACCESSORIE...

Страница 27: ...ies with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable coll...

Страница 28: ...ange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the pr...

Отзывы: