background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

M-Bus / BACnet/IP

 

 

Document code: MN67694_ENG     Revision 1.000   Page 1 of 25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English 

 

M-Bus / BACnet/IP - Converter 

(Order Code:  HD67694-IP-B2-1-10, HD67694-IP-B2-3-25, 
HD67694-IP-B2-15-50, HD67694-IP-B2-30-75, HD67694-IP-B2-50-100) 

 

For Website information:  

www.adfweb.com?Product=HD67694

   

 

For Price information: 

www.adfweb.com?Price=HD67694-IP-B2-1-10

 

www.adfweb.com?Price=HD67694-IP-B2-3-25

 

www.adfweb.com?Price=HD67694-IP-B2-15-50

 

www.adfweb.com?Price=HD67694-IP-B2-30-75

 

www.adfweb.com?Price=HD67694-IP-B2-50-100

 

 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple electrical isolation 

 

Temperature range: -40°C/85°C (-40°F/185°F) 

For others M-Bus products see also the following link: 

 

Converter M-Bus to  

www.adfweb.com?Product=HD67021

      

(RS232)

 

www.adfweb.com?Product=HD67022

      

(RS485)

 

 

Analyzer / Scanner /Sniffer M-Bus 

www.adfweb.com?Product=HD67031

 

 

Isolator/Repeater M-Bus 

www.adfweb.com?Product=HD67032M

 

 

Gateway M-Bus / Modbus RTU  

www.adfweb.com?Product=HD67029M-232

     

(on RS232) 

www.adfweb.com?Product=HD67029M-485

     

(on RS485)

 

 

Gateway M-Bus / Modbus TCP 

www.adfweb.com?Product=HD67044

 

 

Gateway M-Bus / CANopen 

www.adfweb.com?Product=HD67051-B2

 

 

Gateway M-Bus / PROFIBUS

 

www.adfweb.com?Product=HD67053M

 

 

Gateway M-Bus Concentrator 

www.adfweb.com?Product=HD67054M

 

 

Gateway M-Bus Slave / Modbus RTU master 

www.adfweb.com?Product=HD67059M-232

 

 

Do you have an your customer protocol? 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Содержание HD67694-IP-B2-1-10

Страница 1: ...ture range 40 C 85 C 40 F 185 F For others M Bus products see also the following link Converter M Bus to www adfweb com Product HD67021 RS232 www adfweb com Product HD67022 RS485 Analyzer Scanner Snif...

Страница 2: ...SUPPORT 25 RETURN POLICY 25 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product...

Страница 3: ...e can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual M Bus BACnet IP Document code MN67694_ENG Revision 1 000 Page 4 of 25 EXAMPLE OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual M Bus BACnet IP Document code MN67694_ENG Revision 1 000 Page 5 of 25 CONNECTION SCHEME Figure 1 Connection scheme for HD67694 IP B2 xx xxx...

Страница 6: ...nd many others They allows the following characteristics Electrical isolation between BACnet IP and M Bus Baud Rate and Parity changeable with software Mountable on 35mm Rail DIN Wide power supply inp...

Страница 7: ...epends to the code of the device For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 15V 21V 18V 35V Consumption at 24V DC Device No Load W VA Full Load W VA HD67695 B2 1 10 3 5 4 HD...

Страница 8: ...position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for u...

Страница 9: ...Mode Boot Mode 1 Device State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Not used yellow OFF Blinks quickly Boot state Blinks very slowly 0 5Hz upd...

Страница 10: ...ds to a cable resistance of up 29 This distance applies for the standard configuration having Baud rates between 300 and 9600 Baud and a maximum of 250 slaves The maximum distance can be increased by...

Страница 11: ...device The Ethernet connection must be made using Connector2 of HD67694 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T56...

Страница 12: ...with Windows called SW67694 It is downloadable from the site www adfweb com and its operation is described in this document this manual is referenced to the last version of the software present on ou...

Страница 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable M Bus BACnet IP Converter in order to configure another device in the same manner it i...

Страница 14: ...language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to ch...

Страница 15: ...M Bus BACnet IP Document code MN67694_ENG Revision 1 000 Page 15 of 25 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the t...

Страница 16: ...BACnet communication is 47808 but is possible to insert any value In the field BACnet Device Name the name of BACnet IP side of the converter is defined In the field Device Identifier the device inst...

Страница 17: ...y or Secondary Address is defined In the field M Bus ID the ID of the M Bus controller is defined If the field Node State is checked the Status of the controller is mapped on Modbus side If the field...

Страница 18: ...means of the fields are If the field Enable is checked the rule is enabled In the field IP Address the IP Address of the device to which addressing the broadcast messages is defined In the field SubNe...

Страница 19: ...cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Di...

Страница 20: ...ram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program more...

Страница 21: ...rial Electronic Devices ADFweb com S r l User Manual M Bus BACnet IP Document code MN67694_ENG Revision 1 000 Page 21 of 25 MECHANICAL DIMENSIONS Figure 8 Mechanical dimensions scheme for HD67694 B2 x...

Страница 22: ...10 standard M Bus slaves 25 Up to 25 standard M Bus slaves 50 Up to 50 standard M Bus slaves 75 Up to 75 standard M Bus slaves 100 Up to 100 standard M Bus slaves Number of M Bus heating controllers c...

Страница 23: ...e HD67694 B2 30 75 M Bus BACnet IP Converter 30 heating controllers up to 75 M Bus slaves Order Code HD67694 B2 50 100 M Bus BACnet IP Converter 50 heating controllers up to 100 M Bus slaves ACCESSORI...

Страница 24: ...systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recyclin...

Страница 25: ...he following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the...