Industrial
Electronic Devices
ADFweb.com S.r.l.
User Manual
CAN / Modbus TCP Slave
Document code: MN67515_ENG Revision 2.100 Page 17 of 30
RECEIVE COB:
By pressing the “
Receive COB
” button from the main window for SW67515 (Fig. 2) the window “Receive CAN Frames Definition” appears
(Fig. 4). In this section, it is possible to define the CAN frames that the converter will receive from CAN network.
If “Device till April 2014 (with Jumper)” is set in the section “Set Communication”, the window appears like below:
In the field “
Cob-ID
” insert the Cob-ID of the CAN frame;
In the field “
Dimension
” insert the number of bytes of the CAN frame (the maximum dimension is 8 Bytes);
If the field “
TimeOut
” is checked, after the timeout defined in the “Set Communication” window the value of the data of the CAN
frame become “0”;
In the field “
Mnemonic
” a description of the frame is defined.
Figure 4a: “Receive CAN Frame Definition” window