background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

J1939 / CAN - Converter 

 

Document code: MN67439_ENG     Revision 1.101  Page 2 of 33 

    Page 2 of 33 

 

INDEX: 

 
 

 

Page 

INDEX 

UPDATED DOCUMENTATION 

REVISION LIST 

WARNING 

TRADEMARKS 

SECURITY ALERT 

EXAMPLES OF CONNECTION 

CONNECTION SCHEME 

CHARACTERISTICS 

CONFIGURATION 

POWER SUPPLY 

LEDS 

J1939 

10 

CAN 

11 

USB 

12 

USE OF COMPOSITOR SW67439 

13 

NEW PROJECT / OPEN PROJECT 

14 

SOFTWARE OPTIONS 

15 

SET COMMUNICATION 

16 

RECEIVE J1939 

17 

TRANSMIT J1939 

18 

RECEIVE CAN 

19 

TRANSMIT CAN 

21 

UPDATE DEVICE 

23 

UPDATE DEVICE USB 

24 

MECHANICAL DIMENSIONS 

26 

ORDER CODE 

30 

ACCESSORIES 

31 

DISCLAIMER 

32 

OTHER REGULATIONS AND STANDARDS 

32 

WARRANTIES AND TECHNICAL SUPPORT 

33 

RETURN POLICY 

33 

Pagina 2 di 33

 

UPDATED DOCUMENTATION: 

 

Dear  customer,  we  thank  you  for  your  attention  and  we  remind  you  that 
you need to check that the following document is: 

 

Updated 

 

Related to the product you own

 

 
To  obtain  the  most  recently  updated document,  note  the  “document  code” 
that appears at the top right-hand corner of each page of this document. 
 
With  this  “Document  Code”  go  to  web  page  www.adfweb.com/download/ 
and  search  for  the  corresponding  code  on  the  page.  Click  on  the  proper 
“Document Code” and download the updates. 

 

 

REVISION LIST: 

 

Revision  Date 

Author  Chapter  Description 

1.000 

16/10/2014 

Dp 

All 

First released version 

1.100 

15/06/2016 

Ff 

All 

New hardware version 

1.101 

13/03/2017 

Ff 

All 

Revision 

 

 

 

 

 

 

WARNING: 
 

ADFweb.com reserves the right to change information in this manual about 
our product without warning. 
ADFweb.com is not responsible for any error this manual may contain.

 

 
 

TRADEMARKS: 
 

All  trademarks  mentioned  in  this  document  belong  to  their  respective 
owners. 

Содержание HD67439

Страница 1: ...ing links www adfweb com Product HD67212 Modbus RTU CANopen to Modbus See also the following links www adfweb com Product HD67001 Modbus RTU Master www adfweb com Product HD67002 Modbus RTU Slave www...

Страница 2: ...33 RETURN POLICY 33 Pagina 2 di 33 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the p...

Страница 3: ...erlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation...

Страница 4: ...ronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 4 of 33 Page 4 of 33 EXAMPL...

Страница 5: ...om Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 5 of 33 Page 5 of 33 CONNECTION SCHEME Figure 1a...

Страница 6: ...ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 6 of 33 Page 6 of 33 Figure 1b Connectio...

Страница 7: ...tors or AMP SuperSeal 1 5 connectors If is resined the enclosure like the AMP SuperSeal 1 5 connectors is waterproof All the four series have these characteristics Triple 4kV isolation between Power S...

Страница 8: ...e 8 of 33 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax HD67439 Exx xxx 8V 26V 10V 40V Consumption at 2...

Страница 9: ...cribed in the table below LED Normal Mode Boot Mode 1 USB link yellow ON USB cable inserted OFF USB cable not inserted ON USB cable inserted OFF USB cable not inserted 2 Device state green Blinks slow...

Страница 10: ...the HD67439 E7x xxx device must be made with a AMP SuperSeal 1 5 Male connector The pinout of Female connector of the board is at right side of the page The termination of J1939 line with a 120 resist...

Страница 11: ...he HD67439 E7x xxx device must be made with a AMP SuperSeal 1 5 Male connector The pinout of Female connector of the board is at right side of the page The termination of CAN line with a 120 resistor...

Страница 12: ...w adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 12 of 33 Page 12 of 33 USB The USB port is used to start the converter in Boot Mode an...

Страница 13: ...67439 To configure the Converter use the available software that runs with Windows called SW67439 It is downloadable on the site www adfweb com and its operation is described in this document This man...

Страница 14: ...lder which contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable J1939 CAN Converter in order to configure...

Страница 15: ...n there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the sectio...

Страница 16: ...he window Set Communication Setting appears Fig 3 The meaning of the fields of J1939 are In the field Baudrate the data rate of J1939 bus is defined In the field TimeOut Data s a time is defined When...

Страница 17: ...t sends the frame is defined If the field Transport Protocol is checked the frame will use Transport Protocol functions it is used to send more than 8 bytes In the field Start Byte the starting byte t...

Страница 18: ...ity and 7 is the lowest In the field Data Page the data page of the J1939 message is defined The value can be 0 or 1 usually it is 0 In the field PGN the PGN of the J1939 message to be written from CA...

Страница 19: ...me from 1 to 8 is defined In the field Byte1 the offset of the internal array where saving byte 1 of the CAN frame is defined In the field Byte2 the offset of the internal array where saving byte 2 of...

Страница 20: ...t code MN67439_ENG Revision 1 101 Page 20 of 33 Page 20 of 33 In the field TimeOut the time in ms of the timeout of the data is defined If a CAN frame is not received in this time all the data of the...

Страница 21: ...of the internal array where taking byte 1 of the CAN frame is defined In the field Byte2 the offset of the internal array where taking byte 2 of the CAN frame is defined In the field Byte3 the offset...

Страница 22: ...r Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 22 of 33 Page 22 of 33 If the field Time is checked the CAN frame is sent cyclically In the field Time ms the delay in ms bet...

Страница 23: ...are if is necessary In order to load the parameters or update the firmware in the Converter follow these instructions Connect the AC67400 to the PC Connect the CAN port of AC67400 to a CAN port of HD6...

Страница 24: ...guration into the device and also the Firmware if is necessary using the USB port In order to load the parameters or update the firmware in the device follow these instructions Connect the USB cable f...

Страница 25: ...try to do the Update before require assistance try these points Check if the serial COM port selected is the correct one Check if the AC67400 is connected between the PC and the device Check if the US...

Страница 26: ...onic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 26 of 33 Page 26 of 33 MECHA...

Страница 27: ...l Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 27 of 33 Page 27 of...

Страница 28: ...l Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 28 of 33 Page 28 of...

Страница 29: ...l Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 CAN Converter Document code MN67439_ENG Revision 1 101 Page 29 of 33 Page 29 of...

Страница 30: ...ONS The ordering part number is formed by a valid combination of the following HD67439 E y z s d f Fixing lugs A Type 1 B Type 2 C Type 3 D without fixing lugs J1939 Termination Y Terminated with 120...

Страница 31: ...01 Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 Rail DIN Power Supply 110V AC 50 60Hz 12 V AC Order Code AC67402 Cable Super Seal 1 5 MALE 2 pole 1 0 Meter Order Code AC67402 3...

Страница 32: ...opean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an app...

Страница 33: ...wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information...

Отзывы: