CHARACTERISTICS: 
 

The “

HD674-A044

” series are rugged devices used to interface J1939 devices with a MQTT network. 

With his  particular  enclosure,  equipped  with  four  fixing lugs,  makes  available  the  mounting  of  the  device  in  any  plane  surface  (horizontal, 
vertical, oblique).  
It  is  possible  to  have  the  device  varnished  or  totally  resined  and  also  in  both  cases  with  “Mini-Fit®”  connectors  or  “AMP  SuperSeal  1.5” 
connectors. If is resined, the enclosure, like the “AMP SuperSeal 1.5" connectors, is waterproof (IP63). 
 
The device have these characteristics: 

 

Triple 4kV isolation between Power Supply / Ethernet / CAN; 

 

Varnished / Resined (optionally); 

 

Wide power supply input range: 8…26V AC | 10…40V DC; 

 

Mini-Fit® / AMP SuperSeal 1.5 connectors; 

 

Metal enclosure with fixing lugs; 

 

Possibility to use Metal hose clamps for fixing it without using lugs; 

 

Microprocessor for data control; 

 

Wide temperature range: -40°C / 105°C (-40°F / 221°F). 

 

 

CONFIGURATION: 
 

You need Compositor SW674-A044 software on your PC in order to perform the following: 

 

Define the parameter of the MQTT bus; 

 

Define the parameter of the J1939 bus; 

 

Define the MQTT topics to be published/subscribed in the MQTT Server; 

 

Define the list of J1939 messages in reception and in transmission; 

 

Update device. 

Содержание HD674-A044

Страница 1: ...105 C 40 F 221 F For other Gateways Bridges CAN from to Modbus See also the following links www adfweb com product HD67012 Modbus RTU Slave www adfweb com product HD67514 Modbus TCP Master www adfweb...

Страница 2: ...AND STANDARDS 33 WARRANTIES AND TECHNICAL SUPPORT 34 RETURN POLICY 34 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following d...

Страница 3: ...ks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation asse...

Страница 4: ...Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 MQTT Converter Document code MN674 A044_ENG Revision 1 000 Page 4 of 34 EXAMPLE OF...

Страница 5: ...eb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 MQTT Converter Document code MN674 A044_ENG Revision 1 000 Page 5 of 34 CONNECTION SCHEME Figure 1a Conne...

Страница 6: ...ices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 MQTT Converter Document code MN674 A044_ENG Revision 1 000 Page 6 of 34 Figure 1b Connection sch...

Страница 7: ...ors If is resined the enclosure like the AMP SuperSeal 1 5 connectors is waterproof IP63 The device have these characteristics Triple 4kV isolation between Power Supply Ethernet CAN Varnished Resined...

Страница 8: ...4 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax HD674 A044 Exx xx 8V 26V 10V 40V Consumption at 24V DC...

Страница 9: ...ings of the LEDs are described in the table below LED Normal Mode Boot Mode 1 Device state green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 MQTT communic...

Страница 10: ...rms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of...

Страница 11: ...G Revision 1 000 Page 11 of 34 CAN For terminating the CAN line with a 120 resistor it is necessary that the Dip1 of Dip Switch B is at ON position Cable characteristics DC parameter Impedance 70 Ohm...

Страница 12: ...e the available software that runs with Windows called SW674 A044 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last ve...

Страница 13: ...hich contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable J1939 MQTT Converter in order to configure anoth...

Страница 14: ...is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Conne...

Страница 15: ...39 0438 30 91 31 User Manual J1939 MQTT Converter Document code MN674 A044_ENG Revision 1 000 Page 15 of 34 In the section Software Settings it is possible to enable disable some keyboard s commands f...

Страница 16: ...fine the fundamental communication parameters of two buses J1939 and MQTT By Pressing the Set Communication button from the main window for SW674 A044 Fig 2 the window Set Communication appears Fig 3...

Страница 17: ...bled If the field Obtain an IP Address Automatically DHCP for Wi Fi Connection is checked DHCP for Wi Fi connection is enabled If the field Enable DNS is checked DNS protocol is enabled In the field P...

Страница 18: ...them since all the ACK messages are exchanged correctly valid only for QoS 1 and QoS 2 If the field Will Flag is checked the converter will publish the Will topic at the connection to the Server With...

Страница 19: ...In the field Gateway the default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net TLS This section is u...

Страница 20: ...nt code MN674 A044_ENG Revision 1 000 Page 20 of 34 Figure 3g Set Communication NTP window NTP This section is used to define the general parameters of TLS The means of the fields are In the field Ser...

Страница 21: ...s defined the retained flag is enabled The MQTT server will hold the last topic published In the field QoS the QoS level is defined In the field Data Type the type of data to use is defined In the fie...

Страница 22: ...d Topic the MQTT topic is defined In the field QoS the QoS level is defined In the field Data Type the type of data to use is defined In the field Dimension the dimension in byte of the data is define...

Страница 23: ...of the data of J1939 message is defined it is an identifier In the field Source Address the address of the device that sends the frame is defined If the field Transport Protocol is checked the frame...

Страница 24: ...tocol it is a number among 0 1 2 3 4 5 6 7 The number 0 is the highest priority and 7 is the lowest In the field Data Page the Data Page is defined the value can be 0 or 1 usually it is 0 In the field...

Страница 25: ...2 205 Turn ON the device Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When a...

Страница 26: ...the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Sev...

Страница 27: ...r the MQTT messages The template is necessary in order to define the structure of the payload of the MQTT message and the info contained It is possible to have a simple text format or a JSON format Th...

Страница 28: ...lectronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 MQTT Converter Document code MN674 A044_ENG Revision 1 000 Page 28 of 34 MECHANICAL...

Страница 29: ...strial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 MQTT Converter Document code MN674 A044_ENG Revision 1 000 Page 29 of 34 Ty...

Страница 30: ...strial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 MQTT Converter Document code MN674 A044_ENG Revision 1 000 Page 30 of 34 Ty...

Страница 31: ...strial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 MQTT Converter Document code MN674 A044_ENG Revision 1 000 Page 31 of 34 Ty...

Страница 32: ...E y z s f Fixing lugs A Type A B Type B C Type C D without fixing lugs NMEA 2000 Termination Y Terminated with 120 N Not terminated Varnished Resinated V Varnished R Resined Connectors Type 4 MiniFit...

Страница 33: ...countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicab...

Страница 34: ...to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about...

Отзывы: