SET COMMUNICATION:
This section define the fundamental communication parameters of two buses, DMX and PROFINET.
By Pressing the “
Set Communication
” button from the main window of SW674-A028 (Fig. 2) the
window “Set Communication” appears (Fig. 3).
The meaning of the fields of “PROFINET” are:
In the field “
IP ADDRESS
” the IP address of the PROFINET side of the converter is defined;
In the field “
SUBNET
Mask
” the SubNet Mask of the PROFINET side of the converter is
defined;
In the field “
GATEWAY
” the default gateway of the network is defined. This feature can be
enabled or disabled pressing the Check Box field. This feature is used for going out of the net;
In the field “
Port
” the port used for PROFINET communication is defined (fixed to ‘34964’);
In the field "
PROFINET Name of Station
" the name to the PROFINET side of the converter is
defined.
The means of the fields for the “DMX” section are:
In the field “
DMX
” it is possible to define if the converter will act as DMX controller (“OUT”) or
as DMX device (“IN”);
In the field “
Channel Number
” the number of channels of the DMX side is defined (up to 496
channels).
Figure 3: “Set Communication” window