SET COMMUNICATION:

 

 

 

This  section  define  the  fundamental  communication  parameters  of  two  buses,  NMEA  2000  and 
EtherNet/IP. 
 
By Pressing the “

Set Communication

” button from the main window for SW67458 (Fig. 2) the window 

“Set Communication” appears (Fig. 3). 
The window is divided in two sections, one for the EtherNet/IP and the other for the NMEA 2000. 
 
The means of the fields for “EtherNet/IP” are: 

 

In the field “

IP ADDRESS

” the IP address of the EtherNet/IP

 

side of the converter is defined; 

 

In the field “

SUBNET

 

Mask

” the SubNet Mask of the EtherNet/IP

 

side of the converter is defined; 

 

In  the  field  “

GATEWAY

”  the  default  gateway  of  the  network  is  defined.  This  feature  can  be 

enabled or disabled pressing the Check Box field. This feature is used for going out of the net; 

 

In  the  field  “

Port

”  the  port  used  for  EtherNet/IP

 

communication is  defined.  The  port  has  a  fixed 

value of 34964; 

 

In  the  field  “

Number  Byte  Input

”  the  number  of  byte  from  the  EtherNet/IP  to  the  converter  is 

defined (at maximum it is possible to use 496 byte); 

 

In  the  field  “

Number  Byte  Input

”  the  number  of  byte  from  the  converter  to  the  EtherNet/IP  is 

defined (at maximum it is possible to use 496 byte). 

 
The means of the fields for the “NMEA 2000” section are: 

 

In the field “

Baud Rate

” the baud rate of the NMEA 2000 is defined; 

 

In the field “

Time Out  Data (s)

” the timeout  of the data is defined.  If this time is elapsed,  the 

value of the data of the NMEA 2000 frame become “0xFF” (if the “Cancel Data” field is checked in 
the “Receive NMEA 2000” section); 

 

If the field “

Enable Peer to Peer

” is checked, the gateway accepts  all the ID that have the 

PGN inserted in the “Receive Frames” section. 

 

Figure 3: “Set Communication” window

 

Содержание HD67223-A1

Страница 1: ...e 40 C 105 C 40 F 221 F For other Gateways Bridges CAN from to Modbus See also the following links www adfweb com product HD67012 Modbus RTU Slave www adfweb com product HD67514 Modbus TCP Master www adfweb com product HD67515 Modbus TCP Slave CANopen from to Modbus See also the following links www adfweb com product HD67001 Modbus RTU Master www adfweb com product HD67502 Modbus RTU Slave www adf...

Страница 2: ...TANDARDS 30 WARRANTIES AND TECHNICAL SUPPORT 31 RETURN POLICY 31 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Docume...

Страница 3: ...erlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a ...

Страница 4: ...ctronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 2000 EtherNet IP Converter Document code MN67458_ENG Revision 1 000 Page 4 of 31 EXAMPLE OF CONNECTION ...

Страница 5: ... com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 2000 EtherNet IP Converter Document code MN67458_ENG Revision 1 000 Page 5 of 31 CONNECTION SCHEME Figure 1a Connection scheme for HD67458 E4x xx ...

Страница 6: ...es ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 2000 EtherNet IP Converter Document code MN67458_ENG Revision 1 000 Page 6 of 31 Figure 1b Connection scheme for HD67458 E7x xx ...

Страница 7: ...r AMP SuperSeal 1 5 connectors If is resined the enclosure like the AMP SuperSeal 1 5 connectors is waterproof IP63 The device have these characteristics Triple 4kV isolation between Power Supply Ethernet CAN Varnished Resined optionally Wide power supply input range 8 26V AC 10 40V DC Mini Fit AMP SuperSeal 1 5 connectors Metal enclosure with fixing lugs Possibility to use Metal hose clamps for f...

Страница 8: ...Page 8 of 31 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax HD67458 Exx xx 8V 26V 10V 40V Consumption at 24V DC Device W VA HD67458 Exx xx 4 Note It is possible to use also negative tensions In this case the polarity must be inverted Caution Not reverse the polarity power HD67458 E4x xx HD67458 E7x xx ...

Страница 9: ...rious meanings of the LEDs are described in the table below LED Normal Mode Boot Mode 1 Device state green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 CAN Communication green Blinks when NMEA 2000 frames are received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 USB link yellow OFF ON 4 Ethernet communication green Blinks when...

Страница 10: ...0 in the HD67458 E7x xx device must be made with a AMP SuperSeal 1 5 Male connector The pinout of Female connector of the board is at right side of the page The termination of NMEA 2000 line with a 120Ω resistor in the HD67458 Exx xx is made internally of the device when the order is performed If the device have the EtherNet IP terminated the code is the follow HD67458 Exx Yx otherwise is this oth...

Страница 11: ...68 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable The connection of EtherNet IP in the HD67458 E4x xx device must be made with RJ45 connector The connection of the EtherNet IP in the HD67458 E7x xx device must be made with a AMP Su...

Страница 12: ...erter use the available software that runs with Windows called SW67458 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 10 32 64bit When launching the SW67458 the window below appears Fig 2 Note It is necessary to have...

Страница 13: ...hich contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable NMEA 2000 EtherNet IP Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplica...

Страница 14: ...n there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67458 chec...

Страница 15: ...0438 30 91 31 User Manual NMEA 2000 EtherNet IP Converter Document code MN67458_ENG Revision 1 000 Page 15 of 31 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the tables contained in the different sections of the software ...

Страница 16: ...network is defined This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Port the port used for EtherNet IP communication is defined The port has a fixed value of 34964 In the field Number Byte Input the number of byte from the EtherNet IP to the converter is defined at maximum it is possible to use 496 byte In the field Num...

Страница 17: ...efined If the field Transport Protocol is checked the frame can use transport protocol functions If the field Fast Packet is checked the frame will use the Fast Packet functions In the field Start Byte the starting byte to save internal memory array is defined In the field N Bytes the number of consecutive byte from the starting one is defined For example if the Start Byte is 20 and Num Bytes is 1...

Страница 18: ... message to send is defined in NMEA 2000 protocol the PGN is an identifier In the field Source Address the address of the device that sends the frame is defined If the field Fast Packet is checked the frame will use the Fast Packet functions In the field Num Byte the number of bytes of the NMEA 2000 message is defined In the field Transmition Type the transmission type is defined o On Data Change ...

Страница 19: ... 168 2 205 Turn ON the device Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK the updating is done Remove the USB cable If you know the actual IP address of the device you have to use this procedure Turn ON the Device with the Ethernet cable insert...

Страница 20: ...ns for the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program more than one device using the UDP Update you have to cancel the ARP table every time you conne...

Страница 21: ...FIGURATION The configuration and commissioning of the EtherNet IP Converter as described on the following pages was accomplished with the help of the RSLogix 5000 software of Rockwell Automation In case of using a control system from another supplier please attend to the associated documentation These are the steps to follow 1 Create a Generic Ethernet Module under the Ethernet section in the I O ...

Страница 22: ...INT shall be selected as the data type The HD67589 A1 can uses up to 500 bytes for input assembly instance 101 and 500 bytes for output assembly instance 100 RSLogix 5000 requires a configuration assembly instance Both modules do not provide a configuration assembly instance Therefore it is allowed to select an instance of 3 and to set the value to zero 3 The setting of 10msec for the Requested Pa...

Страница 23: ...m Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 2000 EtherNet IP Converter Document code MN67458_ENG Revision 1 000 Page 23 of 31 4 After the configuration is completed the controller tags are created ...

Страница 24: ... 31 User Manual NMEA 2000 EtherNet IP Converter Document code MN67458_ENG Revision 1 000 Page 24 of 31 5 With RSLinks Classic Lite after have done a network scan RSWho and finding the EtherNet IP device it is possible to load the EDS file for the device in order to have the Module Info compiled Before After ...

Страница 25: ...tronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 2000 EtherNet IP Converter Document code MN67458_ENG Revision 1 000 Page 25 of 31 MECHANICAL DIMENSIONS ...

Страница 26: ...ial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 2000 EtherNet IP Converter Document code MN67458_ENG Revision 1 000 Page 26 of 31 Type A ...

Страница 27: ...ial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 2000 EtherNet IP Converter Document code MN67458_ENG Revision 1 000 Page 27 of 31 Type B ...

Страница 28: ...ial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 2000 EtherNet IP Converter Document code MN67458_ENG Revision 1 000 Page 28 of 31 Type C ...

Страница 29: ... z s f Fixing lugs A Type A B Type B C Type C D without fixing lugs NMEA 2000 Termination Y Terminated with 120Ω N Not terminated Varnished Resinated V Varnished R Resined Connectors Type 4 MiniFit 7 SuperSeal 1 5 Enclosure Type E Metal enclosure Device Family HD67458 NMEA 2000 EtherNet IP Converter ACCESSORIES Order Code AC34011 Rail DIN Power Supply 220 240V AC 50 60Hz 12 V DC Order Code AC34012...

Страница 30: ...opean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of huma...

Страница 31: ...wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twel...

Отзывы: