SET COMMUNICATION:
This section define the fundamental communication parameters of two buses, NMEA 2000 and
EtherNet/IP.
By Pressing the “
Set Communication
” button from the main window for SW67458 (Fig. 2) the window
“Set Communication” appears (Fig. 3).
The window is divided in two sections, one for the EtherNet/IP and the other for the NMEA 2000.
The means of the fields for “EtherNet/IP” are:
In the field “
IP ADDRESS
” the IP address of the EtherNet/IP
side of the converter is defined;
In the field “
SUBNET
Mask
” the SubNet Mask of the EtherNet/IP
side of the converter is defined;
In the field “
GATEWAY
” the default gateway of the network is defined. This feature can be
enabled or disabled pressing the Check Box field. This feature is used for going out of the net;
In the field “
Port
” the port used for EtherNet/IP
communication is defined. The port has a fixed
value of 34964;
In the field “
Number Byte Input
” the number of byte from the EtherNet/IP to the converter is
defined (at maximum it is possible to use 496 byte);
In the field “
Number Byte Input
” the number of byte from the converter to the EtherNet/IP is
defined (at maximum it is possible to use 496 byte).
The means of the fields for the “NMEA 2000” section are:
In the field “
Baud Rate
” the baud rate of the NMEA 2000 is defined;
In the field “
Time Out Data (s)
” the timeout of the data is defined. If this time is elapsed, the
value of the data of the NMEA 2000 frame become “0xFF” (if the “Cancel Data” field is checked in
the “Receive NMEA 2000” section);
If the field “
Enable Peer to Peer
” is checked, the gateway accepts all the ID that have the
PGN inserted in the “Receive Frames” section.
Figure 3: “Set Communication” window