Replace locking pin
and turn 90
°
to lock.
45
44
Quick-release trigger
42
41
43
MagnaClean Micro2
incorporates a secure, quick-release, trigger which enables the filter to be
removed and reinstalled in seconds. The connections enable easy and swift filter removal during
servicing or to undertake a
MagnaCleanse
system flush. This also makes it ideal for systems where
there is little room to install a filter.
The following instructions are designed to support engineers in the safe and effective servicing of
MagnaClean Micro2
using the quick-release trigger.
Note: Follow servicing steps 1, 2, 3 and 4 before following Quick-release trigger steps below.
Disconnect.
Turn locking pin 90
°
and remove.
Remove.
Clean collets and lubricate
seals with water.
Fit quick release
trigger and canister
onto valves.