Adey MagnaClean Micro 2 Скачать руководство пользователя страница 2

  

MagnaClean

®

 Micro

2

 has been developed by the company that pioneered  

magnetic filtration. ADEY’s filters protect more than three million central heating systems 
in UK homes removing virtually 100% of the damaging suspended black iron oxide 
sludge that builds up in all heating systems. 

The dual-action filter can be installed anywhere on the main circuit. However, to achieve 
the best level of protection for the boiler, it is recommended that MagnaClean Micro2 is 
fitted after the last radiator and before the boiler.

Installation

Open vented system

Combi/Sealed system

Your system is protected by

Annual service required

www.adey.com

Lubricate 
with jointing 
compound

2

 

Servicing

3

 

 

2

1

4

2

 

Open drain

Close 
drain

Open vent

Take care not to 
over tighten

4

 

No need to  
over tighten

7

 

6

 

7

 

CUT AND REMOVE SECTION

1

1

2

3

 

Tighten compression nuts 

4

 

5

 

8

 

9

 

6

 

2

1

3

Open 
vent    

Turn 
valves 
ON    

10

 

1

2

3

Open vent    

Turn 
valves 
OFF    

1

 

3

1

2

3

4

Clean 

Clean 

5

 

Clean 

Remove sleeve

1

2

3

Open 
vent    

Turn 
valves 
ON    

8

Ensure pin is in 
locked position

Micro

Micro

98mm

The following instructions are designed to support 
engineers in the safe and effective installation 
and servicing of MagnaClean Micro2 and should 
be followed at all times. Ensure the filling loop 
is fitted after the filter. The lid seal should be 
checked for wear when servicing MagnaClean. It is 
best practice to replace the lid seal at each service. 
To arrange replacements please visit adeyspares.
co.uk or contact the ADEY Team on 01242 546717.

In both diagrams, position A is 
recommended as part of ADEY’s Best 
Practice

 approach. Position B is suitable 

if space is tight on the return. 
When completing a system flush using 
MagnaCleanse

®

 always ensure this is 

installed and carried out on the return 
pipe of the system for optimum boiler 
protection.

Close 
vent    

Close 
vent    

Close 
vent    

Close 
vent    

Отзывы: