Adey MagnaClean Micro 2 Скачать руководство пользователя страница 1

  

2

 

Telephone: 01242 546717     Email: [email protected]  

www.adey.com

Produced from recycled material

A carbon neutral company

 

Installation and servicing 

instructions

M02730                         LF2-01-01366

MagnaClean

®

 Micro2 incorporates a secure, quick-release, trigger which  

enables the filter to be removed and re-installed in seconds. 
The industry leading connections are an integral part of the new MagnaClean  
Micro2
 design. They enable easy and speedy filter removal during annual  
servicing or to undertake a MagnaCleanse system flush. This also makes it ideal for 
systems where there is little room to install a filter. 
The following instructions are designed to support engineers in the safe and  
effective servicing of MagnaClean Micro2 using the quick-release trigger.

Quick-release trigger

FOR BEST RESULTS  

Install and service with MC1+, the advanced system inhibitor from 
the UK’s No 1 manufacturer of magnetic filters.

Micro

Micro

1

 

5

4

 

N.B. Periodically remove collets 
and lubricate seals with water

Replace the collets,  
quick-release trigger  
and canister.

3

 

Turn locking pin 90

˚

 

and remove

Replace locking pin 
and turn 90

˚

 to lock

CAUTION:

 

 

MagnaClean

 filter contains a strong magnet. Keep away from all electrical 

devices, bank cards and other magnetic devices.

 

 

MagnaClean

 filter contains a strong magnet. Caution should be taken at all 

times when handling if you have a pacemaker fitted.

 

 

MagnaClean

 filter is a pressurized device. Always release pressure  

before servicing.

 

Unit may be hot in operation. Handle with care.

IMPORTANT Always follow the Standard Electrical Best Practice guidelines when installing a 
MagnaClean filter. A copy of these can be found at http://www.hse.gov.uk/electricity 

To maintain earth continuity in accordance with current IEE regulations, when required a 
suitable earth bonding cable should be fitted to the pipework to bypass the product.  
Refer to NICEIC 17th edition for more information

  

Maximum working pressure: 

6 bar  

 

Maximum working temperature: 

95°C

Flow rate: 

<50 

l/min 

   

Flow:  

Bi-directional

Valve A:  

Double depth socket, slip couplet   

Valve B:  

Single depth socket

Отзывы: