Installation and servicing
instructions
M02730 LF2-01-01366
MagnaClean
®
Micro2 incorporates a secure, quick-release, trigger which
enables the filter to be removed and re-installed in seconds.
The industry leading connections are an integral part of the new MagnaClean
Micro2 design. They enable easy and speedy filter removal during annual
servicing or to undertake a MagnaCleanse system flush. This also makes it ideal for
systems where there is little room to install a filter.
The following instructions are designed to support engineers in the safe and
effective servicing of MagnaClean Micro2 using the quick-release trigger.
Quick-release trigger
FOR BEST RESULTS
Install and service with MC1+, the advanced system inhibitor from
the UK’s No 1 manufacturer of magnetic filters.
Micro
Micro
1
5
4
N.B. Periodically remove collets
and lubricate seals with water
Replace the collets,
quick-release trigger
and canister.
3
Turn locking pin 90
˚
and remove
Replace locking pin
and turn 90
˚
to lock
CAUTION:
MagnaClean
filter contains a strong magnet. Keep away from all electrical
devices, bank cards and other magnetic devices.
MagnaClean
filter contains a strong magnet. Caution should be taken at all
times when handling if you have a pacemaker fitted.
MagnaClean
filter is a pressurized device. Always release pressure
before servicing.
Unit may be hot in operation. Handle with care.
IMPORTANT Always follow the Standard Electrical Best Practice guidelines when installing a
MagnaClean filter. A copy of these can be found at http://www.hse.gov.uk/electricity
To maintain earth continuity in accordance with current IEE regulations, when required a
suitable earth bonding cable should be fitted to the pipework to bypass the product.
Refer to NICEIC 17th edition for more information
Maximum working pressure:
6 bar
Maximum working temperature:
95°C
Flow rate:
<50
l/min
Flow:
Bi-directional
Valve A:
Double depth socket, slip couplet
Valve B: