Adeunis RF PULSE V3 Скачать руководство пользователя страница 1

 

 

 

Page 1 / 21 

 

 

adeunis

®

 

Manage & optimize your assets & services 

283, rue louis Néel 38920 CROLLES, France 

Tél : +33 (0)4 76 92 07 77 E-mail : [email protected] 

www.adeunis.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PULSE V3 
Technical Reference Manual 
LoRaWAN / Sigfox 

 

Applicable for APP versions >= 2.0.0 

 

 

 

 

Содержание PULSE V3

Страница 1: ...age optimize your assets services 283 rue louis Néel 38920 CROLLES France Tél 33 0 4 76 92 07 77 E mail sales adeunis com www adeunis com PULSE V3 Technical Reference Manual LoRaWAN Sigfox Applicable for APP versions 2 0 0 ...

Страница 2: ...riques Déclaration de conformité Fonctionnalités et modes du produit Dimensions du boitier Caractéristiques boitier et électrique Explication des LED Câblage sur bornier spécifique au produit TECHNICAL REFERENCE MANUAL Dedicated to a product Registers content Frame explanations uplink and downlink Dédié à un produit Contenu des registres Explication des trames uplink et downlink INSTALLATION GUIDE...

Страница 3: ...0 1 4 STATUS BYTE 10 1 5 UPLINK FRAME FORMAT 10 1 5 1 Product configuration 0x10 10 1 5 2 Network configuration 0x20 13 1 5 3 Keep alive frame 0x30 14 1 5 4 Periodic data without historisation 0x46 15 1 5 5 Alarm frame 0x47 15 1 5 6 Periodic frame with historisation 0x5A 0x5B 16 1 5 7 Response to Get register request 0x31 17 1 5 8 Response to Set register request 0x33 17 1 5 9 Transmit conditions ...

Страница 4: ...in Max Value Comments 301 2 10 Transmit period of data 1 0 65535 Number of backups history logs to be done before sending a frame thus defining the sending period The value 0 is equivalent to disabling the periodic mode 320 1 16 Channels configuration 0x11 chA ON chB ON 0 0xFF For channel A Bit 0 channel A activation Value 0 channel deactivated Value 1 channel activated Bit 1 meter type channel A ...

Страница 5: ...Value 3 20 ms Value 4 50 ms Value 5 100 ms Value 6 200 ms Value 7 500 ms Value 8 1 s Value 9 2 s Value A 5 s Value B 10 s Value C à F reserved 323 4 10 Current index value channel A 0 0 4294967295 Unit number of pulses In COMMAND mode it is possible to write a new value in this register for example an initialization value an adjustment value Warning this register does not contain current counter 3...

Страница 6: ...s than 24 hours otherwise the product will be perpetually in alarm 331 2 10 Number of daily periods under the leak threshold channel B 0 0 1440 0 deactivated The multiplication of this register by the period of flow measurement must be less than 24 hours otherwise the product will be perpetually in alarm 332 1 10 Scan period for Channel A tamper input 2 1 255 x10 seconds 333 1 10 Tamper detection ...

Страница 7: ... APP KEY second part MID MSB Hexadecimal 218 LORA APP KEY third part MID LSB Hexadecimal 219 LORA APP KEY fourth part LSB Hexadecimal 220 LoRaWAN Options Hexadecimal Default 5 EU 1 US915 AS923 Bit 0 Activation of the ADR ON 1 OFF 0 Bit 1 Reserved Bit 2 DUTYCYCLE ON 1 DUTYCYCLE OFF 0 Bits 3 4 Reserved Bits 5 to 7 Reserved CAUTION Deactivation of the Duty Cycle may result in a violation of the condi...

Страница 8: ...es the APP_ EUI S214 and S215 and APP_KEY S216 to S219 codes during this phase to create the keys for network communication Once this phase is completed the codes APP_sKEY NWK_sKEY and DEVICE ADDRESS will be present in the corresponding registers A new JOIN phase is started every time the device exits Command mode a reset is performed or the device is turned on Codes APP_EUI identifier for global ...

Страница 9: ...7 77 E mail sales adeunis com www adeunis com 1 3 2 Sigfox Network Registers Register Size bytes Base Description Default Value Range Min Max Comments 307 2 10 Sigfox Downlink period 1440 24h 0 65535 X 1 minute Period 1 min to 45 days 317 1 10 Sigfox Duty Cycle 1 0 1 0 duty cycle activated 1 duty cycle deactivated ...

Страница 10: ... enough 1 5 Uplink Frame format 1 5 1 Product configuration 0x10 1 5 1 1 LoRaWAN EU868 This frame is sent following the reception of a frame with code 0x01 or at the start of the product Offset in byte Data Description 0 0x10 Frame code 1 Status Status byte 2 S306 Product mode 3 4 S301 Transmit period expressed in number of historizations 5 S320 Input configuration Channels A et B 6 7 S321 Histori...

Страница 11: ...set to 30 000 impulses per hour 15 16 0x000A 10 decimal threshold tamper detection Channel A set to 10 impulses per hour 17 18 0x0000 threshold tamper detection Channel B set to 0 impulse per hour 19 20 0x0003 number of daily periods under tamper threshold Channel A set to 3 21 22 0x0005 number of daily periods under tamper threshold Channel B set to 5 23 0x01 sampling period of tamper 1 set to 1 ...

Страница 12: ...period is set to 60min In order to optimize the sending of the start frames the 0x11 frame is only sent if the over flow or leak alarm is active If at least one of the following conditions is checked the frame is sent S326 0 S327 0 S330 0 S331 0 Offset in byte Data Description 0 0x11 Frame code 1 Status Status byte 2 3 S326 Flow threshold channel A 4 5 S327 Flow threshold channel B 6 7 S328 Leak t...

Страница 13: ...rm for tamper 2 10 S340 Number of redundant samples per frame Decoding example Offset in byte Data Description 0 0x12 Frame code 1 0x40 Frame counter 2 Bit1 0 configuration consistent 2 3 0x0003 number of daily periods under tamper threshold Channel A set to 3 4 5 0x0005 number of daily periods under tamper threshold Channel B set to 5 6 0x01 sampling period of tamper 1 set to 1 7 0x03 number of s...

Страница 14: ...frame 0x30 This frame 0x30 is transmitted 24 hours after the startup of the application or after the transmission of the previous Keep Alive frame Offset in byte Data Description 0 0x30 Frame code 1 Status Status byte 2 Alarms bit to 1 if the alarm is activated else 0 Bit 0 Exceeding flow on channel A Bit 1 Exceeding flow on channel B Bit 2 Tamper detected on channel A Bit 3 Tamper detected on cha...

Страница 15: ...is frame 0x46 is transmitted at the frequency defined in register S321 and only if register 301 is set to 1 Offset in byte Data Description 0 0x46 Frame code 1 Status Status byte 2 5 Counter channel A Counter value for channel A when transmitting the frame 6 9 Counter channel B Counter value for channel B when transmitting the frame Decoding example Offset in byte Data Description 0 0x46 Frame cod...

Страница 16: ...er frame LoRaWAN EU868 23 index samples Sigfox 4 index samples LoRaWAN US915 AS923 3 index samples Offset in byte Data Description 0 0x5A 0x5B Frame code Channel A 0x5A Channel B 0x5B 1 Status Status byte 2 5 Index at t0 WARNING if max capacity in the frame is reached the warning bit appeared in status byte In this case the product will send the most recent samples at the expense of the oldest one...

Страница 17: ...considering that value 2 is a 1 byte register 5 8 0x00000000 0 considering that value 3 is a 4 byte register 1 5 8 Response to Set register request 0x33 Following reception of a downlink frame with the code 0x41 the frame 0x33 is transmitted It shows whether the downlink frame 0x41 has been received and gives information on the support status of the latter Offset in byte Data Description 0 0x33 Fr...

Страница 18: ...S915 LoRaWAN AS923 0x10 0x11 0x12 Network status All 0x20 Start the product switch to RUN mode Out of configuration mode AT command 0x02 frame reception network config recovery Daily frame keep alive All 0x30 24 hours have passed since the start or last sending of this frame Periodic data frame without history All 0x46 Start the product switch to RUN mode Exit configuration mode AT command Shippin...

Страница 19: ...e on each channel Offset in byte Data Description 0 0x03 Frame code 1 4 Offset channel A Offset channel A numbers of pulses to add to current index of the meter channel A unsigned 32 bits MSB first 5 8 Offset channel B Offset channel B numbers of pulses to add to current index of the meter channel B unsigned 32 bits MSB first Coding example Offset in byte Data Description 0 0x03 Frame code 1 4 0x0...

Страница 20: ...nk frame 0x31 Offset in byte Data Description 0 0x40 Frame code 1 CONFID1 Index of the register to be sent The corresponding register is 300 CONFIDX value 2 CONFID2 3 CONFID3 IMPORTANT the user can specify several CONF IDs in the downlink frame but it is up to the user s responsibility to verify that according to the protocol the size of the data available in a downlink will be large enough to con...

Страница 21: ...ng register is 300 CONFID2 4 5 Value of CONF ID 2 Value to set In this example its value is contained in 2 bytes Following the sending of the downlink 0x41 the associated uplink 0x33 is immediately returned If the update of the register s went well the device will perform a backup and begin its restart procedure automatically In addition the Config bit of the status byte will be set to 1 in the ne...