LoRaWAN Demonstrator (Provider) - User guide version V1.2
page : 15 / 24
5.2
Command Interface
All commands are written in ASCII
Commands can be used once the device has been placed in command mode. The commands are based on AT commands format
and are structures as follows:
x
Starts with 2 ASCII characters “AT”
x
Followed by 1 or more ASCII characters depending on the command
x
Ends by <CR> or <CR><LF>
After receiving a command, the device will emit the following response:
x
ASCII character “O” if the command is accepted
x
ASCII character “E” if the command is rejected
x
Ends by <CR><LF>
The following commands are available:
Command
Description
Reply example
\FF\FF\FF\FF+++
Entry in command mode
«CM»<cr><lf>
AT/V
Displays the firmware version
«LORA-DEMO _v1.0»<cr><lf>
ATS<n>?
Returns content of register <n>
S<n>=<y><cr><lf> with <y> as the
register content
ATS<n>=<m>
Assign value <m> to register <n>
«O»<cr><lf> if Ok, «E»<cr><lf> if
error
ATR
Reset device configuration to factory settings
«O»<cr><lf>
AT&W
Save the new configuration
«O»<cr><lf>
AT&RST
Reset
«O»<cr><lf>
ATO
Exit command mode
«O»<cr><lf>
ATT63 PROVIDER
PROVIDER password, unlocks some registers
«O»<cr><lf>
ATT63 ROOT
PROVIDER password, unlocks LoRa test mode
«O»<cr><lf>
After modifying a parameter, make sure to save the new configuration by issuing the AT&W command.