INSTALLATION GUIDE

SOL FUSION PLUS® SHOWER MIXER

SYSTEM REQUIREMENTS

Operating Pressures - refer to the Venturi Selection Table on page 2

Unequal Pressure - Venturi jet installed

Operating Pressures

Equal High (Mains) & Equal Low Pressures - Venturi jet removed

Operating Hot Water Temperatures

Operating Cold Water Temperatures

Do not plug outlet when testing.
This shower mixer can be line tested up to 1500kPa (217.6psi)

WHAT IS IN THE PACK

MINIMUM

MAXIMUM

20kPa (2.9psi)

36kPa (5.1psi)

300kPa (43.5psi)

1500kPa (217.6psi)

1500kPa (217.6psi)

55° C

60° C

5° C

N/A

Hot

Cold

Mixer Assembly

2.5mm Allen Key

8g x 32 Dome Head
Square Drive
Stainless Steel Screws

Grub Screw

Handle Cap

AS/NZS 3500.1 states that pressures above 500kPa can cause damage from water hammer, reduce the life of 

appliances, taps & fittings, cause excessive noise in the system and recommend that a pressure limiting valve (PLV) be fitted.

3x Venturi Jets for Unequal Pressures:

36-75kPa

YELLOW

 JET

76-130kPa

RED

 JET

BEFORE INSTALLATION

MIXER ORIENTATION

Pipework MUST be purged before connecting to the mixer

This mixer is designed to be connected with the hot water 

supply on the left only and the cold water supply on the 

right only.
If at any point the cartridge nut is removed, please ensure 

that both black lines marked on the cartridge and cartridge 

nut are aligned when the mixer is in full cold position as 

shown in figure 1.

HOT

INLET

ONLY

COLD

INLET

ONLY

( FULL COLD POSITION )

Figure 1.

OUTLET

Page 1

Patented New Zealand No. 605175 

20-35kPa

GREEN

 JET

Handle

Fac O-Ring

IMPORTANT:

Factory fitted 

WITHOUT

Venturi Jet

Содержание SOL FUSION PLUS

Страница 1: ...at pressures above 500kPa can cause damage from water hammer reduce the life of appliances taps fittings cause excessive noise in the system and recommend that a pressure limiting valve PLV be fitted 3x Venturi Jets for Unequal Pressures 36 75kPa YELLOW JET 76 130kPa RED JET BEFORE INSTALLATION MIXER ORIENTATION Pipework MUST be purged before connecting to the mixer This mixer is designed to be conn...

Страница 2: ...A B C 2 Follow this flowchart to select the correct Venturi Jet for the pressure situation 20 35kPa GREEN JET Recommended for 20 35kPa hot water supply 36 75kPa YELLOW JET Recommended for 36 75kPa or greater hot water supply Please note Performance of the mixer will vary based on the specific pipework between your hot water source and the outlet 76 130kPa RED JET Recommended for 76 130kPa or great...

Страница 3: ... New Zealand No 605175 HOW TO INSTALL 1 No minimum straight distance HOT supply only COLD supply only 3 Apply a silicone bead on the back of the faceplate Cut a hole to suit faceplate Ø90mm Faceplate Min 40mm Max 70mm ...

Страница 4: ...sition as shown in Figure 1 6 Remove the handle and disassemble the mixer 1 Unscrew the Venturi Jet using a 2 5mm Allen Key 3 Refit the correct Venturi Jet into the insert disc and hand tighten firmly 4 Refit the seal with silicone grease if required and then insert disc using the long nose pliers ensuring that the locating pins go into the corresponding sockets 5 Page 4 Locating pin socket FRONT ...

Страница 5: ...pin Reassemble mixer Ensure that both black lines marked on the cartridge and cartridge nut are aligned when the mixer is in full cold position as shown in Figure 1 5 Locating pin Refit the seal with silicone grease if required and then insert disc using the long nose pliers ensuring that the locating pins go into the corresponding sockets Patented New Zealand No 605175 FULL COLD POSITION Figure 1...

Отзывы: