background image

 

II 

 

Contents 

Important Safeguards and Warnings

·············································· 1 

1 General Information

··············································································· 1 

1.1 Use of the Manual

················································································· 1 

1.2 Safety Guidelines

················································································· 1 

1.3 Remember to measure resistance

·························································· 2 

1.4 Lifetime Warranty

················································································· 2 

2 Foil Heating Mat System

········································································ 2

 

2.1 Foil Heating Mat Specifications

······························································ 2 

2.2 Foil Heating Mat typical installations and applications

······························ 2

 

3 Floor Heating Design and Product Selection

········································ 3 

3.1 Design the Installation

·········································································· 3 

3.2 Confirm Your Product Selection

···························································· 4 

4 installation

····························································································· 5 

5 Commissioning

···················································································· 10 

5.1 Insulation Resistance Test

··································································· 10 

5.2 Heating Cable Resistance Test

······························································10 

5.3 Sensor Resistance Test

······································································· 11

 

6 Troubleshooting

··················································································· 12 

EXTENDED WARRANTY

········································································· 13

 

 

 

 

 

 

Содержание HM140/1

Страница 1: ...I Foil Heating Mat System Installation Manual Floor heating System...

Страница 2: ...ystem 2 2 1 Foil Heating Mat Specifications 2 2 2 Foil Heating Mat typical installations and applications 2 3 Floor Heating Design and Product Selection 3 3 1 Design the Installation 3 3 2 Confirm You...

Страница 3: ...l Information 1 1 Use of the Manual Installing Foil Heating Mat is very easy to do Foil Heating Mat Systems combine the highest comfort levels with maximum energy efficiency It s a proven technology t...

Страница 4: ...and after installation of wood floor 1 4 Lifetime Warranty From the date of purchase Adept warrants that the Foil Heating Mat heating cable is free from defects in material design and workmanship The...

Страница 5: ...showers toilets vanities or cabinets Measure the heated area of the floor For example in Figure 3 the area of the bathroom is 8 75 m2 When you subtract the area of the vanity shower and toilet the to...

Страница 6: ...your Foil Heating Mat is no larger than the heated area Following the example from Figure 3 if the heated area is 6 45 m2 select the 6 0 m2 Foil Heating Mat system Figure 3 Heated area example Figure...

Страница 7: ...0 96 9 0 5 18 20 59 1 1260 5 48 42 0 HM140 10 10 107 6 0 5 20 20 66 6 1400 6 09 37 8 HM140 12 12 129 2 0 5 24 20 78 8 1680 7 30 31 5 4 Installation Important Tools and materials required You will req...

Страница 8: ...PS insulation board directly underneath the heating mat s install the boards in a brick pattern below and tape the edges to prevent movement of the underlay during installation Step 4 TRANSFER LAYOUT...

Страница 9: ...e your Foil Heating Mat from the packaging box carry out a resistance test Use a digital ohm meter to measure the resistance of the Foil Heating Mat and compare it to Table Record the measured resista...

Страница 10: ...stalling the flooring NEVER CUT THE HEATING CABLE Step 8 STICK THE CONNECTING TAPE In order to protect the mat from damage we need some necessary protective measures A roll of Aluminum tape and Alumin...

Страница 11: ...king warmth should be noticeable on the surface of the heating mat within minutes You are now ready to lay the final floor finish Take care not to damage the heating mats Do not drive nails or screws...

Страница 12: ...ng on the type of room and your personal preferences 5 Commissioning Important For the extended Lifetime warranty to apply you must perform these tests record the results on the warranty card and reta...

Страница 13: ...ed to verify the sensor integrity 1 Set your multimeter to the 200K ohm range 2 Connect the multimeter leads to the red and green lead wires 3 Make sure the meter reads between 9 25K ohms If you get a...

Страница 14: ...the Product Selection Table of this manual Refer to Thermostat Installation and Operation Manual Refer to Section 4 of this manual and the Thermostat Installation and Operation Manual Refer to Thermos...

Страница 15: ...S ANY WARRANTY EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ADEPT NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON FIRM OR CORPORATION TO ASSUME FOR IT ANY OTHER LIABILITY...

Отзывы: