Chapter 6 - System Operation
100
Adept Cobra i600/i800 Robot User’s Guide, Rev E
Figure 6-14 Diagnostics Wizard Enable Power Sequence
4. The Wizard then tells you to press the blinking
High Power
button on the Front
Panel. See
This step turns on high power to the robot motors.
• The Robot Status LED glows solid amber or, on older iCobras, blinks green
rapidly.
• The code on the Diagnostic Panel displays
ON
.
NOTE:
The Front Panel button must be pressed within 10 seconds.
Figure 6-15 High Power Button on Front Panel
Switch set to
Auto Mode
Press High Power button
when blinking (within
10 seconds)