background image

– 40 –

02 START: ACS PT
(00-31)               00

If the start zone type selected was 27 (access point), this prompt
will be displayed. Enter the access point (00-31) which will
start the relay action.

02 START PART

If the starting event will be limited to occurring on a specific
partition, enter the partition number (1-8) in which the start
event will occur. Enter 0 for any partition.

Press [

] to continue.

02 STOP: ZN LIST
NO LIST

If a zone list is being used to stop this relay action, enter the
zone list number 1-8.   The restore of a zone on the zone list
will stop the relay.  If a zone list is not being used, enter 0.

Press [

] to continue.

02 STOP: ZN TYP

If a Zone Type/System Operation is being used to stop the relay
action, enter the 2-digit code as listed in the “Choices for
Start/Stop Zone Type/System Operation” table.

Press [

] to continue.

02 STOP: ACS PT
(00-31)               00

If the stop zone type selected was 27, (access point), this prompt
will be displayed. Enter the access point (00-31), which will
stop the relay action.

02 STOP PART

This is the partition to which the stop condition will be limited.
Enter 0 for any partition. Enter 1-8 for specific partition
number.

Press [

] to continue.

RELAY GROUP

Relays may be grouped for common activation by time-driven
events (commands 06-10). Enter 0 (no group) or 1-8 for a
specific group number.

Press [

] to continue.

01  FIRE BELL?
1 = YES  0 = NO

If this relay is on a supervised 4204CF Module, it may be used
as an additional fire bell.  Enter 1 (Y) if it is; enter 0 if it is not.
This tells the system which relays are to be activated during a
fire drill or Fire Walk-Test.

Press [

] to continue.

RESTRICTION
1=YES  0=NO

The system may have some devices, which are not intended to
be under end user control, such as relays activating fire doors
or machinery. Enter 1 if the end user will be restricted from
accessing this relay group.  If this is a fire bell, it will be
restricted automatically.

Press [

] to continue.

RELAY TYPE

Enter 0 for V-Plex (polling loop) devices.  Enter 1 for relay
modules (4204/4204CF).  Enter 2 for Powerline Carrier devices.

V-PLEX ZONE #

For polling loop trigger outputs (4101SN), enter the protection
zone number (001-128) linked to each output, if used.  If not
using a protection zone on these modules, enter the relay zone
number (601-632).  Be sure to enroll the module’s serial
number (see Zone Programming prompt earlier in this section).
Press [

] to continue.

Содержание Vista-128FB  

Страница 1: ...V128FB PRV1 10 98 9 9 6 67 7 RPPHUFLDO LUH DQG XUJODU 3DUWLWLRQHG 6HFXULW 6 VWHP ZLWK 6FKHGXOLQJ 4XLFN 6WDUW XLGH FIRE FIRE PULL Previous Menu...

Страница 2: ...2...

Страница 3: ...ontrol and is set to device address 00 Single Partition System The system default is for a single partition system Use the VISTA 128FB SINGLE PARTITION PROGRAMMING FORM when programming for single par...

Страница 4: ...detailed instructions 5 Use 93 Menu Mode for device programming Refer to the DEVICE PROGRAMMING section to assign keypad ID numbers and default partitions for each keypad and to selectively suppress...

Страница 5: ...g the Installer s code use 98 The only way to re access programming mode is by depressing both the and keys at the same time within 30 seconds of power up Exiting by using 99 always allows reentry int...

Страница 6: ...ific 89 Communications 90 Partition Specific 1 01 93 Menu Mode 1 02 93 Menu Mode 1 03 93 Menu Mode 1 04 93 Menu Mode 1 05 93 Menu Mode 1 06 93 Menu Mode 1 07 93 Menu Mode 1 08 93 Menu Mode 1 09 93 Men...

Страница 7: ...2 6 12 hrs 0 normal report about 2 min after AC loss Must be 2 for Central and Remote Station Fire alarm systems 20 VIP MODULE PHONE CODE Enter 01 09 for the first digit enter 00 11 11 for or 12 for...

Страница 8: ...er reports go to secondary only If used with Split Reporting 2 option alarms and alarm restores go to both open close and test messages go to secondary only while all other reports go to primary If us...

Страница 9: ...Commercial Fire UL installations 1 19 ARMS LOBBY 0 Enter 1 if arming this partition attempts to arm lobby enter 0 if it does not Must be 0 for Commercial Fire UL installations 1 20 EXIT ERROR LOGIC 0...

Страница 10: ...d 56 1 75 RELAY TIMEOUT YY SECONDS 000 Enter the relay timeout 0 127 seconds desired for 80 Menu Mode time driven event relay command numbers 05 10 and 93 Menu Mode Relay Programming command 57 1 76 A...

Страница 11: ...DELAY for ZONE TYPES 17 18 00 Waterflow FIre Supv Enter 00 15 times 2 seconds 3 17 ALTERNATE FUNCTION TAMPER 0 FOR ZONE 6 0 disabled 1 enabled 3 18 EXTENDED DELAY FOR TYPES 17 18 0 0 No 1 Yes 3 19 ENA...

Страница 12: ...to next page of program fields press 94 To return to previous set of fields press 99 To erase account phone number field entries press field number To assign zone descriptors press 93 follow menu pro...

Страница 13: ...nes can be bypassed 39 ENABLE OPEN CLOSE REPORT 1 FOR INSTALLER CODE 1 enable 0 disable 84 SWINGER SUPPRESSION 03 01 15 alarms Must be 00 disabled for Commercial Fire UL installations 85 ENABLE DIALER...

Страница 14: ...ity to the installetion 0 disable 1 enable 2 18 ENABLE GOTO FOR THIS PARTITION 0 1 Allow log on from other partitions 0 disable 2 20 ENABLE J7 TRIGGERS by PARTITION 1 0 disable for displayed partition...

Страница 15: ...assignment for zone Input device type for zone whether RF polling loop etc Enrolling serial numbers of 5800 Series transmitters and serial polling loop devices into the system all other zone characte...

Страница 16: ...ramming part of this section for programming alpha descriptors The following is a list of commands used while in the Menu Mode 93 Menu Mode Key Commands 93 Enters Menu Mode Serves as ENTER key Press t...

Страница 17: ...to continue or press the key to back the system up to the PROGRAM TOOL prompt ENTER ZN NO 000 QUIT 010 Zone 010 entered Enter the 3 digit zone number to be programmed protection zones 001 032 relay zo...

Страница 18: ...its which will result in arming the system in the STAY or AWAY mode or disarming of the system depending on the selection made Press to continue 010 ACCESS POINT 00 31 01 If response type 27 was selec...

Страница 19: ...DDR 01 31 01 If input type 09 was selected this prompt will be displayed Enter the ECP address of the keypad that is being used for entry exit for this access point 01 31 010 ACS ZONE NO 00 31 01 If i...

Страница 20: ...sed Enter 0 NO to enroll later If 0 is entered the system will advance to the summary screen prompt 3 4 1 2 ALWAYS USE LOOP 5801 ENROLL AS UR OR RF LOOP 1 5802 5802CP ENROLL AS BR LOOP 1 5802MN ENROLL...

Страница 21: ...ring this step you may press the key on the keypad or the upper left hand button of the program tool if you are satisfied with the serial and loop number combination that has been enrolled regardless...

Страница 22: ...e TECHNOLOGY TYPE prompt PROGRAM TOOL 0 NO 1 YES 0 If a program tool is being used enter 1 If not using a tool enter 0 When a 0 is entered the system will advance to the TECHNOLOGY TYPE prompt 000 INP...

Страница 23: ...u do not wish to enroll the zone displayed press on the keypad or the upper right hand button on the program tool a long beep will be heard to verify The following prompt will appear 010 LEARN S N 0 N...

Страница 24: ...s have been displayed whether enrolled or not the ENTER ZN NO prompt will appear Enter 000 to exit the Sequential Mode and return to Data Field Programming Mode When you have finished programming all...

Страница 25: ...of the Alarm Report code Press to continue ENTER ZONE NO 000 QUIT 001 Enter the zone number for which you are entering the report code When all zone Alarm Codes have been programmed enter 000 to Quit...

Страница 26: ...er 000 Press to continue QUIT REPORT MENU 1 YES 0 NO 0 If you have completely finished entering report codes press 1 Y to quit Report Code Programming If you wish to enter other system report codes en...

Страница 27: ...ort Code Programming If you wish to enter other system report codes enter 0 N Press to continue System Group 3 Codes SYSTEM GROUP 3 1 YES 0 NO 0 To enter System Group 3 codes press 1 Y EARLY OPEN 1st...

Страница 28: ...at are selected from a vocabulary of 244 words stored in memory and any word can have an s or s added to it NOTE Due to the use of 3 digit zone numbers the first word of the descriptor is limited to 6...

Страница 29: ...s follows Assume for example that the desired description for Zone 1 is BACK DOOR a Press followed by the 3 digit number of the first word from the fixed dictionary shown later in this section e g 0 1...

Страница 30: ...d word enter 02 and so on A cursor will now appear at the beginning of the second line 3 Type the word using one of two methods as follows a Press followed by the 2 digit entry for the first letter yo...

Страница 31: ...oceed as follows 1 Select Default Screen Mode The keypad will ask for the partition number for this message Enter the partition number Press to accept entry The following will appear DISARMED READY TO...

Страница 32: ...118 LIGHT 119 LINE 120 LIQUOR 121 LIVING 122 LOADING 123 LOCK 124 LOOP 125 LORRA 126 LOW 127 LOWER 128 MACHINE 129 MAGNETIC 130 MAIDS 131 MAIN 132 MASTER 133 MAT 134 MEDICAL 135 MEDICINE 136 MICROWAV...

Страница 33: ...g 01 30 Press to accept entry Note Device Address 04 must be used for the 4285 4286 Voice Module if one is installed If not it can be used for another device type Device Address 00 is always set as an...

Страница 34: ...ve users with access to multiple partitions the ability to arm and disarm those partitions from it To enable this keypad for global arming disarming enter 1 To prevent the ability to use this keypad f...

Страница 35: ...ing N Y N Press for NO answer Y Press SHIFT Y for YES answer SHIF T Press before pressing a SHIFT key function Will light READY LED LED goes out once a key is pressed Press again for each SHIFT functi...

Страница 36: ...ion Enter N for private system users skip to Question 7 CS ID 11 Enter the primary central station s system ID number 1 7F will not be displayed for private system users BAT PRESENT Y N N Enter Y if o...

Страница 37: ...ions are available 1 EVENT EV is the condition alarm fault trouble that must occur to a zone or group of zones zone list in order to activate the device These conditions apply only when a zone list is...

Страница 38: ...E SYSTEM OPERATION ZT Instead of using a RESTORE ZONE LIST a specific zone response type or system operation action can be selected to de activate the device If a specific ZONE TYPE is chosen any zone...

Страница 39: ...es Choices for Start Stop System Operation 00 No Response Not Used 01 Entry Exit 1 02 Entry exit 2 03 Perimeter 04 Interior Follower 05 Trouble Day Alarm Night 06 24 Hr Silent 07 24 Hr Audible 08 24 H...

Страница 40: ...any partition Enter 1 8 for specific partition number Press to continue RELAY GROUP Relays may be grouped for common activation by time driven events commands 06 10 Enter 0 no group or 1 8 for a spec...

Страница 41: ...ne would be 601 Program this zone for response type 19 24 Hr Trouble in Zone Programming Zone List Programming After all relays have been programmed upon entering 00 at the ENTER RELAY NO prompt you w...

Страница 42: ...l the RLY VOICE DESCR prompt is displayed Follow the instructions below While in this mode press to advance to next screen Press to back up to previous screen RLY VOICE DESCR 0 no 1 yes Press 1 to pro...

Страница 43: ...Five 074 Floor 029 Four 073 Fourth 217 Foyer 137 Word Index Front 087 Garage 023 Gas 138 Glass 139 Hall 050 Heat 010 Inside 209 Kitchen 022 Laundry 140 Left 027 Library 141 Light 019 Living 030 Loadi...

Страница 44: ...the relay voice descriptor and custom word substitutes vocabulary list found in the Relay Voice Descriptors part of this section Press to accept entry The CUSTOM WORD NO prompt will be displayed Ente...

Страница 45: ...This will further simplify the programming process PARTITIONS Partition Descriptor 4 char max Prim Sub Sec Sub Alpha Default Message 32 character maximum Partition 1 Partition 2 Partition 3 Partition...

Страница 46: ...increments Console Annunciation During Entry Console Annunciation During Exit Confirmation of Arming Ding for Bell 1 Confirmation of Arming Ding for Bell 2 Aux Rly Chime on Bell 1 Chime on Bell 2 Aux...

Страница 47: ...6 22 07 23 08 24 09 25 10 26 11 27 12 28 13 29 14 30 15 31 Type 0 Device Not Used 1 Alpha Console 3 RF Receiver 4 Output Relay Module 5 Voice Module 6 Long Range Radio 9 Vista Gateway Module Console S...

Страница 48: ...el Open Close 2 Digit User Global Arm Auth Level Open Close 2 Digit User Global Arm Auth Level Open Close ACCESS CODES USER DEFINITIONS FOR PARTITIONS 7 8 4 digit Access Partition 7 Partition 8 Securi...

Страница 49: ...No Zone Type Parti tion 1 8 Input Type 1 8 Serial Device Loop Bell Relay Activation Report Code Zone Information part numbers Alpha Descriptor 3 words max 01 02 03 04 05 06 07 08 09 010 011 012 013 0...

Страница 50: ...one Type Parti tion 1 8 Input Type 1 8 Serial Device Loop Bell Relay Activation Report Code Zone Information part numbers Alpha Descriptor 3 words max 025 026 027 028 029 030 031 032 033 034 035 036 0...

Страница 51: ...Zone Type Parti tion 1 8 Input Type 1 8 Serial Device Loop Bell Relay Activation Report Code Zone Information part numbers Alpha Descriptor 3 words max 049 050 051 052 053 054 055 056 057 058 059 060...

Страница 52: ...one Type Parti tion 1 8 Input Type 1 8 Serial Device Loop Bell Relay Activation Report Code Zone Information part numbers Alpha Descriptor 3 words max 073 074 075 076 077 078 079 080 081 082 083 084 0...

Страница 53: ...one Type Parti tion 1 8 Input Type 1 8 Serial Device Loop Bell Relay Activation Report Code Zone Information part numbers Alpha Descriptor 3 words max 097 098 099 100 101 102 103 104 105 106 107 108 1...

Страница 54: ...5 126 127 128 ZONE DEFINITIONS FOR KEYPAD PANIC ZONES 995 996 999 Enter yes no for each partition field 22 Zone No Zone Type 1 2 3 4 5 6 7 8 Bell Rel Act Report Code Zone Information part numbers Alph...

Страница 55: ...Code Zone Information part numbers Alpha Descriptor 3 words max Zone No Zone Type Report Code Zone Information part numbers Alpha Descriptor 3 words max 601 617 602 618 603 619 604 620 605 621 606 62...

Страница 56: ...Fire Waterflow 22 disarm 02 entry exit 2 08 24 hour auxiliary 18 Fire Supervisory 23 no alarm response 03 perimeter 09 supervised fire 19 24 hour trouble 27 access control 04 interior follower 10 inte...

Страница 57: ...he installation instructions as you enter the data during the displays and prompts that appear in sequence Note The Device Programming section must be programmed for the device address Set the dip swi...

Страница 58: ...s list device action will START STOP ZONE LIST Upon restore of ALL zones on this list device action will STOP It need not be same list as used for START ZT ZONE TYPE SYSTEM OPERATION Choices for Zone...

Страница 59: ...ed in the 93 Menu Mode in the Relay Programming Section Fill in the required data on the worksheet below and follow the procedure in the installation instructions as you enter the data during the disp...

Страница 60: ...week and holidays Holidays 1 Yes 0 No 0 For defining up to 16 holidays for which partitions they apply Timed Events 1 Yes 0 No 0 For defining up to 20 time driven events with the following parameters...

Страница 61: ...6 17 18 19 20 Keep this worksheet handy as you will be asked for a given time window number later in this section Since the time windows are shared among all partitions it is important to make sure th...

Страница 62: ...ear in sequence HOL Partition Month Day 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Time Driven Event Worksheet The system provides up to 20 time driven events that can be programmed for th...

Страница 63: ...er for commands 20 24 is Partition s Activation times 1 Beginning 2 End 3 During are the only valid choices for auto arming and disarming functions 20 Arm Stay 21 Arm Away 22 Disarm 23 Force Arm Stay...

Страница 64: ...r each partition Enter the temporary scheduling mode by pressing Installer Code 81 Fill in the required data on the worksheet below and follow the procedure in the installation instructions as you ent...

Страница 65: ...tart Time HH MM Stop Time HH MM 6 Disarm Window Start Time HH MM Stop Time HH MM Arm Window Start Time HH MM Stop Time HH MM 7 Disarm Window Start Time HH MM Stop Time HH MM Arm Window Start Time HH M...

Страница 66: ...66...

Страница 67: ...ERFACE TO 5140DLM MAIN DIALER ON HOOK VOLTAGE THRESHOLD INTACT 25V CUT 13V BACK UP DIALER EARTH GROUND SCREW wire to main PCB terminal 30 J2 VOLTAGE TRIGGERS See instructions for trigger use and progr...

Страница 68: ...9 359 l V128FB PRV1 10 98 165 Eileen Way Syosset NY 11791 Copyright 1998 PITTWAY Corporation...

Отзывы: