– 36 –
SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS
Fixed-Word Display Keypads
SOUND
CAUSE
DISPLAY
LOUD,
INTERRUPTED*
Keypad & Ext.
Sounder
Fire Alarm
FIRE and ALARM are displayed; protection zone
in alarm is displayed.
LOUD,
CONTINUOUS*
Keypad & Ext.
Sounder
Burglary / Audible
Emergency Alarm
ALARM is displayed; protection zone in alarm is
also displayed.
Also see page 32.
ONE SHORT BEEP
(not repeated)
Keypad only
System is in Test Mode
Opened zone identifications will appear.
ONE BEEP
(every 40 seconds)
Keypad only
a. Low battery at transmitter
b. System Main Battery Weak
c. Trouble
a. BAT displayed with ID number of transmitter.
b. BAT displayed with no transmitter ID.
c. CHECK
displayed. Troubled protection zone
is displayed.
TWO SHORT
BEEPS
Keypad only
Arm Away or Maximum
AWAY and (if MAXIMUM) INSTANT are
displayed.
THREE SHORT
BEEPS
Keypad only
a. Arm Away or Stay
b. Zone opened while system in Chime Mode
c. Zone opened while system in Test Mode
a. STAY and (if INSTANT) INSTANT are
displayed. Red ARMED indicator is lit.
b. CHIME displayed. Pressing READY [
✴
] key
will display opened zone.
c. Open protection zone number is displayed.
RAPID BEEPING
Keypad only
Memory of Alarm
FIRE and/or ALARM is displayed; zone in alarm
is displayed.
SLOW BEEPING
Keypad only
a. Entry Delay Warning
b. Exit Delay Alert
(if programmed)
a. No display during delay. Exceeding the delay
time without disarming causes alarm.
b. AWAY or (if MAXIMUM) AWAY INSTANT is
displayed. Slow beeps change to fast beeps
during last 5 seconds of exit delay.
*
If bell is used as external sounder, fire alarm is pulsed ring (see page 32); burglary/audible emergency is steady ring.
Note: Also see “Other Trouble Displays” and “Total Power Failure” under TROUBLE CONDITIONS on pages 30 and 31.