4 –
Field
Function
Programmed Values
[ ] = Table 1 Default Value
✱
34
EXIT DELAY
|
†
[70]
00-99 = exit delay time (in seconds).
UL installations = 60 seconds max.
✱
35
ENTRY DELAY 1 (zone type 01)
|
† [30]
00-99 = entry delay time (in seconds);
UL installations = 45 seconds max.
✱
36
ENTRY DELAY 2 (zone type 02)
|
† [60]
00-99 = entry delay 2 time (in seconds);
UL installations = 45 seconds max.
✱
37
AUDIBLE EXIT WARNING /
† [1, 1]
QUICK EXIT
Exit Warn Quick Exit
0 = no; 1 = yes
✱
38
CONFIRMATION OF ARMING DING
† [0]
0 = no; 1 = yes (when armed by self-contained keypad or RF)
2 = yes (when armed by RF keypad only).
✱
39
POWER UP IN PREVIOUS STATE
† [1]
0 = no; 1 = yes; UL installations = 1
† Entry of a number other than one specified will give unpredictable results.
DIALER PROGRAMMING (
✱
40–
✱
53)
In fields
✱
40,
✱
41,
✱
42, enter up to the number of digits shown. Do not fill unused spaces. Enter 0–9; #+11 for '
✱
';
#+12 for '#'; #+13 for a pause.
✱
40
PABX ACCESS CODE
Enter 6 digits. If fewer than 6 digits are entered,
pressing
✱
advances to the next field. To clear entries from field,
press
✱
40
✱
.
✱
41
PRIMARY PHONE No.
Enter up to 20 digits; Do not fill unused spaces. If fewer than 20
digits entered, pressing
✱
advances to the next field. To clear
entries from field, press
✱
41
✱
.
✱
42
SECONDARY PHONE No.
Enter up to 24 digits; Do not fill unused spaces. If fewer than 24
digits entered, pressing
✱
advances to the next field. To clear
entries from field, press
✱
42
✱
.
For fields *43 , *44:
Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. Enter
✱
as 4th digit, if 3+1 dialer
reporting is to be used. If only 3 digits used, pressing
✱
advances to the next field.
To clear entries from field, press
✱
43
✱
or
✱
44
✱
.Examples:
For Acct. 1234, enter: 1 | 2 | 3 | 4 ; For Acct. B234, enter: #+11| 2 | 3 | 4
For Acct. 123, enter: 1 | 2 | 3 |
✱