Programming:

Destiny 6100:

Consult Installation Manual for programming information.

Advantage and Destiny:

Program the number of zones used in each group into the appropriate memory location:

Group 1 : 214

Group 3 : 216

Group 5 : 218

Group 7 : 220

Group 2 : 215

Group 4 : 217

Group 6 : 219

Group 8 : 221

Example: To use all 16 inputs (Groups 1 & 2) on the first HWB-416, program 214,008 and 215,008.

LED- 1:

The green power LED on the HWB-416 indicates power and activity of the four-wire bus.  When the

HWB-416 is operating correctly the LED should have a consistent flash that is often interrupted by

flashing at twice the normal rate.  This indicates signaling on the four wire bus.  Each time a zone is

opened, the LED should flash quickly for a brief moment.  If the LED flashes at a constant rate and

no devices in the system are operating, check all four-wire bus connections.  If the problem persists,

contact technical support at 800-272-7937.

Diagram 2: HWB-416 at default: Lower Group (#1), Upper Group (#2),

Upper and Lower Groups Enabled, 1 E.O.L. resistor on all

upper and lower group inputs.

Diagram 3:  Most Common Dip Switch Settings:

Upper and Lower Groups Enabled,

1 E.O.L. resistor on all upper and

lower group inputs.

ON

8

7

6

5

4

3

2

1

10

9

-

8

7

6

5

4

3

2

1

10

9

-

8

7

6

5

4

3

2

1

10

9

-

8

7

6

5

4

3

2

1

10

9

-

8

7

6

5

4

3

2

1

10

9

ON

ON

ON

ON

Board #1

Lower Group #1 - Upper Group #2

Board #2

Lower Group #3 - Upper Group #4

Board #3

Lower Group #5 - Upper Group #6

Lower Group (1, 3, 5, 7)

Upper Group (2, 4, 6, 8)

Board #4

Lower Group #7 - Upper Group #8

L1

L2   L3    C    L4   L5    C    L6   L7    C    L8    L9   C   L10  L11  C  L12  L13  C   L14  L15  C   L16

C

Отзывы: