Page 6
VISTA-40 SINGLE PARTITION PROGRAMMING FORM
1
✱
3 4 COMM. SPLIT REPORT SELECTION
0=no; 1=alarms primary, others secondary;
2=open/close, test secondary, others primary; See
✱
51 for notes.
DIALER CODES ( Armed Stay, Time Set & Event Logging)
1
✱
4 0
1
✱
4 1
First Digit
Second Digit
Armed STAY
|
|
Time/Date set or event log reset
|
|
1
✱
4 3 PERM. KEYPAD BACKLIGHT
1=enable; 0=disable; When disabled, display lights when any
key is pressed, and turns off after period of keypad inactivity.
1
✱
4 4 WIRELESS KEYPAD
TAMPER DETECT ENABLE
1=enable; 0=disable
1
✱
4 5 EXIT DELAY SOUNDING
1=enable; 0=disable Produces quick beeping during exit delay if
enabled.
1
✱
4 6 AUXILIARY OUTPUT MODE
0=ground start; 1=open/close trigger; 2=keypad sounding;
3=Non-Ademco AAV unit trigger
1
✱
4 7 CHIME ON EXT SIREN
1=enable; 0=disable
1
✱
4 8 WIRELESS KEYPAD ASSIGNMENT
0=disable; enter partition in which RF keypad used, 1-2.
1
✱
4 9 SUPPRESS TX SUPERVISION SOUND
[1]
1=disable; 0=enable.
Must be "0" for UL.
1
✱
5 2 SEND CANCEL IF ALARM + OFF
1=no restriction; 0=within Bell Timeout period only
1
✱
5 3 DOWNLOAD CALLBACK
1=callback not required; 0=callback required; Must be "0" for UL.
1
✱
5 7 ENABLE 5800 RF BUTTON GLOBAL ARM
Enter "1" to have the system arm/disarm following the button's
user's global arm settings. Enter "0" if the button is not to be used
to global arm the system.
1
✱
5 8 ENABLE 5800 RF BUTTON FORCE BYPASS
If zone is faulted after pressing button, keypad will beep once.
User should press button again within 4 sec. to force bypass
those zones. Enter 1 if force bypass is desired. Enter 0 if not
desired.
1
✱
6 0 AAV MODULE SELECT
Enter “1” only if AAV unit is used.
NOTE: If enabled zone 5 can no longer be used as a protection
zone.
1
✱
6 6 SILENCE BELLS DURING AAV
0 = alarm sounders continue during AAV sessions;
1 = alarm sounders silent during AAV sessions, resume after
AAV session (unless timeout has occurred).
Must be "0" for UL.
1
✱
7 0 EVENT LOG TYPES
1=enable logging; 0=disable Alrm Chck Byps O/C Systm
1
✱
7 1 12/24 HOUR TIME STAMP FORMAT
0=12 hour; 1=24 hour
1
✱
7 4 RELAY TIMEOUT XX MINUTES
| |
Enter the relay timeout, 0-127 in multiples of 2 minutes, desired
for #93 Menu Mode Relay Programming output command "56".
1
✱
7 5 RELAY TIMEOUT YY SECONDS
| |
Enter the relay timeout, 0-127 seconds, desired for #93 Menu
Mode Relay Programming command "57".
1
✱
7 6 ACCESS CONTROL RELAY FOR PARTITION |
Enter relay number that will be pulsed for 2 seconds whenever
code + [0] is pressed. Enter 00-08 [00]=none
3rd Page Programming Fields
(press
✱
9 4 )
PARTITIONING SETUP FIELDS
2
✱
0 0 NUMBER OF PARTITIONS
[1]
Enter 1 for single partition systems.
2
✱
0 1 DAYLIGHT SAVINGS TIME [04, 10] | |
START/END MONTH
Start
End
00-12; if no daylight savings time, enter 00,00
2
✱
0 2 DAYLIGHT SAVINGS TIME
[1, 5] |
START/END WEEKEND #
Start | End
Enter 1-7. 1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to
last; 7=3rd from last [default is 1st Sunday in April, last in Oct.]
2
✱
1 7 NUMBER OF CODES PER PARTITION [69] 1 |
Enter 01-69. Total must be less than or equal to 70.
[01] 2 |
2
✱
1 8 ENABLE GOTO FOR THIS PARTITION
1=enable; 0=disable
2
✱
1 9 USE PARTITION DESCRIPTORS
0=disable;
1=enable
2
✱
2 0 ENABLE J7 TRIGGERS by PARTITION
[1]
0=disable for displayed partition; 1=enable for displayed partition
2
✱
2 1 ENABLE SUPERVISION PULSES FOR LRR
TRIGGER OUTPUTS
| |
Used for supervised connection to 7920SE.
F B
S
Enter 0 to disable or 1 to enable the listed outputs.
F= Fire; B= Burglary; S= Silent panic/duress