Страница 1: ...trol panel can be used even with bells connected to the control No 1026 or 1028 series Alarm Processing Centers may not be used as they conta i n Ni Cad standby batteries 1 The 678 may be triggered by I Application or removal of 6 l2V DC supplied from any alarm control or other DC source 2 Dry contact closure 3 Dry contact opening The 678 is easily programmed by the insertion of a PROM Programmabl...

Страница 2: ...e confirms to the 678 that connection has been camp leted to the r ece i ver I f handshake is not received within 30 seconds 60 seconds if so programmed the communicator will disconnect itself from the telephone line After waiting long enough approximately 30 seconds to disconnect any outgoing or incoming calls which might interfere with diali ng anti jam which only works in called party control e...

Страница 3: ...n and stop dialing unless programmed for Unlimited Attempts The 678 has a built in KISS OFF LED which lights upon receipt of kiss of f and goes out 8 seconds after completion of all transmission to that telephone number If the Dual Report option is selected the 678 will make up to 8 attempts to reach each telephone number PROGRAMMING OPTIONS The No 678 may be programmed with a number of opti ons w...

Страница 4: ...8 to look for the SESCOA Franklin DCI acknowledge and acknowledge hold signals and to report in SESCOA format If this option r is not selected the No 678 will respond in the Ademco standard format For Ademco hi speed format see instructions accompanying the No 685 Receiver Channel Programming Options In addition to the system options there are a number of options which can be selected and which af...

Страница 5: ...put going high alarm If the input goes low restores 150 msec de lay app I ies This feature permits the 678 to report a restore on the same call as it reports an alarm thus reducing the frequency with which a i emergency services will be notified in the event of false alarms 4 Secondary Number Only Channels Any channel or channels may be selected to call and report only to the secondary number This...

Страница 6: ...he customer is advised of a successful transmission to the receiver INSTALLATION PROCEDURE Mounting The 678 may be mounted in a No 205 Cabinet or any other enclosure that will accommodate it See GENERAL INFORMATION If a No 205 Cabinet is to be used mount the cabinet in its desired location and install the communicator chassis in it Use the upper set of grooves provided at the side edges of the cab...

Страница 7: ...PROM CHIP PRE PROGRAMMED KfSSOFF LE D V TRIGGERING INPUTS FOR ANY OR ALL CHANNELS IF NEEDED WI SOURCE FOR OPTlotjAL TAMPERED CONNECTION SEE NO 626s INSTRUCTIONS SURGE ARREsiG MAKE SURE RE LEADS ARE COh AS SHOWN TO v lNPUT TERMINAL FORD I A A L ITRIGGERtNG 1 y L VOLTAGE _ 1 D O F ROM BELL TERM 71 I OF CONTROL or OPEN CLOSING SIGNAL VIA No 666 FROM A P C 4 COLD WATER 7 PIPE GROUND TO DC POWER SUPPLY...

Страница 8: ...propriate termina Is Notes a Channel I gives alarm code I channel 2 gives code 2 etc b If the Low Battery Trigger and Report option has been programmed do not use Channe I 8 si nce low battery code is 8 11 1 C For voltage triggering two ground I positions are provided on the terminal block if needed d If one or more channels are to be tr iggered by dry contacts terminals 5 and 6 each provide V dry...

Страница 9: ... WHITE jumper l2V DC For additional information see GENERAL INFORMATION iiote Power sources with nickel cadmium batteries may not be used Activating Inputs Triggering Application or removal of 6 to or full wave rectified or via dry contacts N 0 or N 2V DC battery c 1 Current Dra i n I n standby non activated 135 ma During call activated 260 ma Transmission Format Accommodates Ademco and S ilent Kn...

Страница 10: ...s will be sent Any digit may be entered in first space but select one that will be significant when a receiver accommodating 4 digits is in use 4 SYSTEM OPTIONS Check appropriate space s LOW BATTERY TRIGGER SESCOA FORMAT FRANKLIN DCI 5 CHANNEL OPTIONS Check appropriate space s for each Channel 123456780 Do not use Channe 1 8 i f Low Battery Trigger System Option iS selected INVERTED I I I I I I I ...

Страница 11: ...rammed wi I I be made to reach the central monitoring station via primary and or secondary programed telephone numbers See PROGRAMMINGOPTIONS if the Dual Report option is selected the 678 will make up to 8 attempts to reach each telephone number ADEMCO LOW SPEED REPORTING FORMAT Receipt by the 678 of the standard LOW SPEED acknowIedgment tone from a No 660 Receiver or LOW SPEED acknowledgment tone...

Страница 12: ...reases beyond 1000 Csubscriber identification number 999 the No 685 Z Line C ds caneasily be modified to send sthe high speed acknowledgment tone Subsequently connected addit onal No 678 s may then be programmed with subscri her numbers 1000 through 9999 For the elqht alarm reporting channels digits 5 through 121 the channel status codes are as follows Code I 2 3 4 5 d Mea iti ng NEW ALARM previou...

Страница 13: ...ill at subscriber 5890 following the events of example D above channel 2 restores initiating the call and channels 5 and 8 remain In alarm Subscriber Channel Number Identification 1234 5678 9 Message 5890 5355 Channel 2 NEWRESTORE f Channels 5 8 PREVIOUSLYREPORTED ALARMS sti 11 In effect 0 Subscriber 80135 sends an opening on channel 3 a new alarm on channel 5 and a restore on channel 6 Subscriber...

Страница 14: ...recommend ed that when the number of subscribers zone telco rotary exceeds 999 the high low speed line cards be converted to high speed only by cutting the appropriate jumper on the No 685 2 s circuit board see the No 685 s installation instructions SESCOA REPORTING FORMAT When this option is selected see PROGRAMMINGOPT ONS section the 678 will respond to SESCOA Franklin GCI acknowledge and acknow...

Страница 15: ... as the Nos 96 97 or 497 that cannot supply at least 70 ma continuously A canon power supply from a control panel can be used even with bells connected to the control No 1026 or 1028 Series Alarm Processing Centers may not be used as they contain Ni Cad batteries such as those precluded above The No 678 may be triggered by II Application or removal of 6 l2V DC battery or filtered full wave rectifi...