6128WL Programming
Entering Program Mode
Press the 1 and 3 keys simultaneously for a few seconds within 30 seconds of applying power to the 6128WL. The
keypad will beep 3 times, and 2 dashes and 2 zeroes will flash alternately in the upper left-hand corner of the display. If
any other numbers or letters are flashing in the display, press the [
✳
] key.
Enter a Program Option (e.g., (1) Keypad Address) to program the options of the 6128WL. Press [0] to enter User
Mode. See the User Guide for the purpose of this mode.
While in the program mode, the [
✳
] key stores the information and moves you to the next prompt. The keypad will beep
twice. The [#] key erases the information and moves you back so you may enter the correct information.
The 6128WL is shipped with a set of pre-programmed default values. If needed, the unit may be set back to these
values. See Defaulting the 6128WL later in this manual for the procedure.
Two Programming Methods of the 6128WL
•
System:
When using the 6128WL in place of a stand-alone 5881/5882 RF Receiver.
•
Local:
For all other applications.
1. System Application Programming
Program Option/
Description
Display
Values
1 Keypad
Address
cA
01-31 Default = 31
Enter 1. The display will alternately flash “cA” and a 2-digit
number. Enter the 2-digit keypad address. Press the [
✳
] key to
continue.
2 Receiver
Address
rA
00-30 Default = 00
Enter 2. The display will alternately flash “rA” and a 2-digit
number. Enter the 2-digit address for the receiver. Press the [
✳
]
key to continue.
6 Receiver
r-
1=System, 0=Local
Default = 1
Leave set to the default value (1) System.
Note: Make sure the number of receivers set for System (1) does
not exceed the capacity of the control panel.
Press the [
✳
] key to continue.
This is all the 6128WL programming necessary for this application. If the display takes a long time to show the System
status (“READY” or “NOT READY”), go back into program mode by pressing the 1 & 3 keys at the same time, then press
[1] and verify the keypad address.
2. Local Application Programming
Use this programming section if your application requires either of the elements (wireless keys or RF receiver), of the
6128WL to be set as Local. Refer to the 6128WL Application Guide on page 2 for installations that require these
settings.
The programming section is divided into two parts. The first is Programming the Keypad and the RF Receiver of the
6128WL. The second part is Programming Local Wireless Keys into the 6128WL.
Programming the Keypad, Receiver and Transmitter Module of the 6128WL
Program Option/
Description
Display
Values
1 Keypad
Address
cA
01-31
Default = 31
Enter 1 to program the Keypad Address. The display will alternately
flash “cA” and a 2-digit number. Enter the 2-digit keypad address.
Note: Control panels in the VISTA-10SE and VISTA-20SE families can
only use keypad address 31. Control panels in the VISTA-40 family use
keypad addresses 01-15; the VISTA-50P family uses keypad addresses
01-30.
Press the [
✳
] key to continue.
2 Receiver
Address
rA
00-30
Default = 00
Enter 2 to program the Receiver Address. The display will alternately
flash “rA” and a 2-digit number. Enter the 2-digit address for the
receiver.
Note: Control panels in the VISTA-10SE and VISTA-20SE families can
only use receiver address 00. Control panels in the VISTA-40 family use
receiver addresses 01-15; the VISTA-50P family uses receiver addresses
01-30.
Press the [
✳
] key to continue.