Step Action 

Display 

Enter [4] (Loop Functions). Enter the loop number (1-4).  

Note: 

The 6128RF is shipped with the loop functions preprogrammed. 

Perform steps 6 through 10 only if it is necessary to change any 
of the loop functions. 
Loop 1 

Close the 6128RF On-Board Relay for 2 sec. 

Loop 2 

1 (Disarm) 

Loop 3 

2 (Arm Away) 

Loop 4 

3 (Arm Stay) 

See the Wireless Key Function Chart below for the choices:

 

Wireless Key Function Chart 

 

Function Entry 

 

 

Disarming 1 

 

 

Arming Away 

 

 

Arming Stay 

 

 

Arming Maximum (Away Instant) 

 

 

Arming Instant 

 

 

Panic Alarm   
Produces type of alarm [* & #] 
programmed in control panel. 

# + 99   

 

 

Manually Start a Relay Action 

# + 7 

(VISTA-10SE, VIA-30PSE)

 

# + 7 + n 

(VISTA-10P, VISTA-15P, 

VISTA-20P, VISTA-20PS, 
VISTA-20SE, VISTA-20HWSE)

 

 

 

Manually Stop a Relay Action 

# + 8 

(VISTA-10SE, VIA-30PSE)

 

# + 8 + n  

(VISTA-10P, VISTA-15P, 

VISTA-20P, VISTA-20PS, 
VISTA-20SE, VISTA-20HWSE)

 

 

 

Activate Relay as Programmed in 
Control 

# + 71 

(VISTA-40, VISTA-50P)

 

 

 

Activate Relay as Programmed in 
Control 

# + 72 

(VISTA-40, VISTA-50P)

 

 

 

Activate Access Control Relay for 
Partition 

(VISTA-40, VISTA-50P)

 

 

n = Device Number programmed into these panels to be controlled 

Press the [

] key.

 

Flashing "Ln." 

Once the loop number is 
entered, alternately flashes 
"L" with the loop number 
and the present function. 

 

Default Loop Functions 

 

LOOP 4

Arm STAY

LOOP 3
Arm AWAY

LOOP 1
Close on-board relay
for 2 seconds

LOOP 2
Disarm

ON

OFF

5 8 0 4 - 0 0 2 - V 0

5804

 

 
 
 

••

• •

•••

LOOP 3

Arm AWAY

LOOP 4
Arm STAY

LOOP 1
Close on-board relay
for 2 seconds

LOOP 2
Disarm

5 8 0 4 B D - 0 0 2 - V 0

5804BD

SET

HOUSE

CODE

 

Repeat step 6 for the rest of the loops of the wireless key.  

 

To program a button on the wireless key to control the on-board 
relay, enter [5] (On -Board Relay Assignment).  

Flashing "o-." 

Enter the loop number of the wireless key (1-4). Enter the relay 
action (0 = no action; 1 = relay off; 2 = relay on; 3 = relay toggles on & 
off; 4 = relay closes for 2 seconds).  

Note:

 The relay action must be "0" for UL installations. 

Press the [

] key. 

Flashing “o” and the loop 
number. 

Once the action is entered, 
the display will show “o” 
and alternately flash the 
loop number and the relay 
action. 

10 

Repeat step 9 for the rest of the loops. 

 

11 

When all loops have been programmed for the wireless key, press the 
[

] key. 

Flashing “d” followed by the 
device number. 

12 

The 6128RF will automatically display the next available device 
number (one that does not have a serial number). 

If you desire to program additional wireless keys, repeat steps 3 
through 10. Otherwise, press the [

#

] key.  This will take you back to 

the main display, that will alternately flash “oo” and “- -.” 

Press the [

] to exit the 6128RF Program Mode. 

 

Note:

  Upon exiting of the Program Mode, the 6128RF will alternately flash "Ad," the 2-digit keypad address, 

and the 2-digit receiver address.  If either of these is incorrect, repeat steps 1 through 3 under 

Programming for 

an Installation Without Local Wireless Keys

.

 

Содержание 6128RF

Страница 1: ...the wireless keys Provides a method for deleting a serial number and re enrolling a new one in its place Provides default settings for the functions of the wireless keys Additional Features Can send s...

Страница 2: ...If set for Local on a partition control the 6128RF s partition assignment must match the one programmed in the BD device Installing the 6128RF Locate the 6128RF in an area and at a height where it is...

Страница 3: ...s the information then moves you to the next prompt The keypad will beep twice The key erases the current information and moves you back so you may enter the correct information Enter a Program Addres...

Страница 4: ...structions for the acceptable keypad and receiver addresses If you are using a wireless key in high security mode 5804E in the control panel it will occupy one of the devices in the 6128RF Programming...

Страница 5: ...he House ID is needed only if an RF keypad and or bi directional units is used and House ID source is set for Local The House ID entered here MUST match the House ID programmed in the RF keypad and th...

Страница 6: ...relay for 2 seconds LOOP 2 Disarm ON OFF 5804 002 V0 5804 LOOP 3 Arm AWAY LOOP 4 Arm STAY LOOP 1 Close on board relay for 2 seconds LOOP 2 Disarm 5804BD 002 V0 5804BD SET HOUSE CODE 7 Repeat step 6 fo...

Страница 7: ...ing of the Program Mode the 6128RF will alternately flash Ad the 2 digit keypad address and the 2 digit receiver address If the either of these is incorrect repeat steps 1 through 3 under Programming...

Страница 8: ...er 165 Eileen Way Syosset New York 11791 warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and...

Отзывы: