4208U 

Universal Eight Zone Remote 

Point Module

INSTALLATION AND SETUP GUIDE 

FEATURES 

The ADEMCO 4208U Remote Point Module (RPM) is an 8-
zone expander that allows use of available expansion zones 
provided by ADEMCO controls that support polling loop 
devices.  Characteristics of this device include:   

• 

Can be optionally powered from an external DC power 
supply to reduce the amount of current draw from the 
polling loop. 

• 

Uniquely identifies 8 EOLR supervised zones (all zones 
use 10k resistors, supplied). 

• 

DIP Switches can be used to set zone numbers or serial 
numbers. 

• 

When used in the serial number mode, each serial 
number in the selected group can be assigned to any 
zone number. 

• 

Loops A & B can be programmed for fast (10msec) 
response. 

• 

Tamper protected. 

MOUNTING 

 

1.  Power should be disconnected 

before proceeding.   

2.  Be sure to mount the 4208U before 

making any wire connections 

When mounted remotely, tamper protection is required.  
Holes on the back of the module’s housing permit it to be 
mounted horizontally or vertically.  Wires can exit from the 
side or the breakout on the back of the housing.  To enable 
tamper protection, set DIP Switch 8 to OFF and attach the 
tamper magnet (provided) (Figure 1) to the module inside 
cover.  Be sure to enable the expansion zone tamper option 
at the control (program field *24 = 0).  If the module’s cover 
is removed, the magnet attached to the cover (positioned 
near the reed switch) will cause a tamper signal to be sent 
to the control for every active zone on the 4208U module.  
When the installation is complete, install the cover and affix 
the Serial Number and Zone Assignment Tables to the 
inside cover of the control.   

When mounted inside the cabinet with the control, the 
4208U should be mounted horizontally and does not need 
tamper  protection,  provided  the  cabinet  is  supervised.  
Insert two screws into the raised metal tabs leaving the 
heads app. 1/8” exposed, then hang the 4208U using the two 
slots on the back. 

1. INSERT BOTTOM TABS FIRST.
2. ENGAGE TOP WITH CLIP.

4219-002-V0

 

Figure 1.  Tamper Magnet Installation 

WIRING 

CE

 

For CE installations ADEMCO N6361 
EMI suppression bead is required. 

 

Refer to the N6361 installation guide for 
wire routing instructions.  
 

Polling loop and protection loop wires can be brought in 
either through the back or front of the unit by removing the 
knockouts.  Use 22 gauge twisted pair wire for polling loop 
connections.  All protection loops use 10k EOL resistors 
(included).  A maximum resistance of 300 ohms is allowed 
on protection loops (excluding EOLR).  See Figure 2 for all 
connections.  Keep in mind that connections to the polling 
loop are always required, while power supply connections 
are optional.   

DIP SWITCH SETTINGS 

Zone Assignment Mode:   

In the zone assignment mode, the DIP Switches on the 4208 
are used to assign the unit to a group of 8 consecutive zones.  
These zone numbers, once designated for the 4208U, cannot 
be used for anything else, even if you don’t use all 8.  Follow 
the steps below using Table 1 for DIP Switch settings.   

Serial Number Mode:   

In the serial number mode, the DIP Switches on the 4208U 
are used to assign the unit to a group of 8 serial numbers.  
You can assign any serial number to any zone number 
(except hardwire zone numbers of the control) and you do 
not lose zone numbers if you don’t use all eight loops on the 
4208U.  Follow steps below using Table 2 for DIP Switch 
settings.   

UL

 

For all fire (NFPA) and UL Commercial 
Burglary installations, the 4208U must 
be tamper protected or mounted in a 
tamper-protected cabinet.  
 