TO DETERMINE TOTAL STANDBY LOAD
ON BATTERY, ADD 100mA TO TOTAL OF
AUX. POWER OUTPUT AND REMOTE
KEYPAD CURRENTS.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

EARTH GROUND

SEE INSTRUCTIONS
FOR PROPER GROUNDING

TELEPHONE WIRING

(VIA RJ31X* JACK DIRECT 

CONNECT CORD)

*IN CANADA, CA38A JACK

No. 4127:

20mA

No. 4137AD:    60mA
No. 6127:

20mA

No. 6128:

30mA

No. 6137:

85mA

OR

No. 5330:

105mA

BLACK: KEYPAD GROUND (–) RETURN

RED: KEYPAD PWR (+)

GREEN: DATA IN FROM KEYPAD 

YELLOW: DATA OUT TO KEYPAD 

REMOTE 

KEYPAD

AUX. POWER

OUTPUT

10.5-13.8VDC

500mA MAX. 

INTERRUPTS

FOR FIRE

ALARM RESET

NOTE: 
KEYPAD 
CURRENT MUST
BE INCLUDED IN
AUX. CURRENT
DRAIN 
CALCULATIONS

}

GEL LEAD ACID TYPE.

BATTERY NORMALLY NEED NOT BE 
REPLACED FOR AT LEAST 3 YRS.

BATTERY CAPACITY FOR EMERGENCY
STANDBY USE AT LEAST 4 HOURS.

BATTERY

12V, 4AH

OR 12V, 1.2AH

+

+

CONNECTOR TABS

USE UL LISTED  

LIMITED ENERGY

CABLE FOR ALL

CONNECTIONS

FOR COMPLETE

INFORMATION, SEE

INSTRUCTIONS

N5478V4

PLUG-IN TRANS-
FORMER
16.5VAC, 25VA
(e.g. ADEMCO 
No. 1321/TF2. 
USE No. 1321CN 
IN CANADA

TO 110VAC

UNSWITCHED 

OUTLET (24HR)

+

CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE
ALARM HEADQUARTERS OR A CENTRAL STATION
SHALL BE PERMITTED ONLY WITH THE PERMISSION
OF THE LOCAL AUTHORITY HAVING JURISDICTION.
THE BURGLAR ALARM SIGNAL SHALL NOT BE CON-
NECTED TO A POLICE EMERGENCY NUMBER.

ALARM OUTPUT
10.5-13.8VDC, 2A MAX.
(600mA MAX FOR UL USAGE,
INCLUDING AUX. POWER)

STEADY FOR BURGLARY/PANIC,
PULSING FOR FIRE (e.g. USE ADEMCO
No. 702 OR 719 SIREN, OR 12V BELL)

FUSE

FOR REPLACEMENT,

USE SAME VALUE

3A

BLK
RED
GRN
YEL

1000 

OHMS

EOLR

1000 

OHMS

EOLR

ZONE 5

ZONE 6

HI

LO

HI

LO

TIP

(BROWN)

RING

(GRAY)

TIP

(GREEN)

RING

(RED)

}

}

INCOMING

PHONE LINE

LOCATED AT 
LOWER RIGHT OF 
CIRCUIT BOARD

HANDSET

BLACK

RED

+

1000 

OHMS

EOLR

1000 

OHMS

EOLR

ZONE 1

ZONE 2

HI

LO

HI

LO

1000 

OHMS

EOLR

1000 

OHMS

EOLR

ZONE 3

ZONE 4

HI

LO

HI

LO

• MAXIMUM LOOP RESISTANCE  (EACH ZONE) 300 OHMS (PLUS EOLR)
• RESPONSE, ZONES 1-6: 300-500MSEC
• ZONE 3 CAN BE PROGRAMMED FOR N.C. SENSOR FAST RESPONSE TO AN

OPEN: 10MSEC MAX

• ZONE 5 CAN BE PROGRAMMED FOR USE AS A FIRE ZONE.  SEE DIAGRAM

No. 4116

ARMING/DISARMING

KEYSWITCH

(SINGLE LED, LOCKSWITCH,

TAMPER)

BATTERY

(e.g. No. 90-12)

CHARGING

VOLTAGE

13.8VDC

NOTE: MULTIPLE KEYPADS MAY BE
USED, BUT EACH 5330 KEYPAD
MUST BE ON AN INDIVIDUAL HOME
RUN. USE MAX. OF 220FT. OF #22
WIRE OR 550 FT. OF #18 WIRE.

WARNING:

TO PREVENT RISK OF SHOCK, 
DISCONNECT TELEPHONE LINE
AT TELCO JACK BEFORE
SERVICING THIS UNIT.

THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE PRO-
TECTION ASSOCIATION’S STANDARD 74 (NATION-
AL FIRE PROTECTION ASSOC., BATTERYMARCH
PARK, QUINCY, MA 02269). PRINTED INFORMA-
TION DESCRIBING PROPER INSTALLATION,
OPERATION, TESTING, MAINTENANCE, EVACUA-
TION PLANNING AND REPAIR SERVICE IS TO BE
PROVIDED WITH THIS EQUIPMENT.

THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION
IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) IT MAY NOT
CAUSE HARMFUL INTERFERENCE, (2) IT MUST ACCEPT ANY INTER-
FERENCE THAT MAY CAUSE  UNDESIRED OPERATION.

COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC398U-68192-AL-E
RINGER EQUIVALENCE: 0.7B.

WARNING:

OWNER’S INSTRUCTION NOTICE NOT TO BE
REMOVED. WEEKLY TESTING IS REQUIRED TO
ENSURE PROPER OPERATION OF THIS SYSTEM.

DOC LOAD NO.: 3

BLK
RED
GRN
YEL

No. 4281L or 4281M

RF RECEIVER

WIRELESS ZONES

4281L: UP TO 4

4281M: UP TO 8

{

OPTIONAL

SET RECEIVER’S DIP SWITCH
FOR DEVICE ADDRESS OF “0”
SEE RECEIVER’S INSTRUCTIONS

OR

AUX PWR

OUTPUT

TERMS

+

-

+

-

+

EOL
POWER
SUPER-
VISION
RELAY
MODULE
A77-716B

5

4

4-WIRE SMOKE

OR COMBUSTION 

DETECTOR

1000

OHMS

EOLR

HEAT
DETECTOR

ZONE 5

*

+

RED

BLK

VIOLET

*

IF PROGRAMMED FOR FIRE

-

Содержание 4110XM

Страница 1: ...S E C U R I T Y S Y S T E M 4110XM N5478V5 7 96 Installation Instructions Installation Instructions Installation Instructions SEE INSIDE COVER FOR IMPORTANT NEW FEATURES AND INFORMATION Previous Menu...

Страница 2: ...dom time delay up to 1 hour If AC is restored before the report goes out no report will be sent 6 Telephone number entries can now contain and a 2 second pause Enter 11 for Enter 12 for Enter 13 for 2...

Страница 3: ...10 The Mechanics of Programming 10 Entering Program Mode 10 Programming a Data Field 10 Reviewing a Data Field 10 Erasing an Entry in a Data Field 10 Downloading 10 Clearing All Data Fields 10 Exiting...

Страница 4: ...osed Smoke could be blocked by the closed door Also an alarm in the hallway outside may not wake up the sleeper if the door is closed Install a smoke detector inside bedrooms where electrical applianc...

Страница 5: ...a 12VDC 2 AMP output assumes a fully charged 4AH battery is connected Steady output for Burglary Panic or pulsing output for Fire Output is current limited Communication Formats Ademco Low Speed Stan...

Страница 6: ...eet Optional Keyswitch 4116 Keyswitch ZONE RESPONSE TYPE CHARACTERISTICS Zone Response Type Characteristics 0 Zone Disabled 1 Entry Exit Burglary Provides exit delay time when panel is armed in any ar...

Страница 7: ...CABINET DOOR BOTTOM RETAINER CLIP RETAINER CLIP NOTE POSITION RETAINER SLOTS LOCKED UNLOCKED Figure 1 Installing The Cabinet Lock Mount the PC board either alone or with the wireless receiver in the...

Страница 8: ...right OFF this equals address 0 as shown in Figure 4 4 3 2 1 ON OFF MOUNTING HOLES INTERFERENCE INDICATOR LED CIRCUIT BOARD DIP SWITCH PLUG SOCKET INSERT IN RIGHT HAND TERMINALS ANTENNAS YELLOW RED B...

Страница 9: ...Telephone Line IMPORTANT Make sure telephones on the premises are connected only through the alarm control panel disconnect from the incoming phone line at the telephone jack This is necessary to have...

Страница 10: ...numbers into the system see program fields 24 and 76 thru 92 Do not permanently mount transmitters until transmission from each location has been verified see Section 5 TESTING THE SYSTEM for instruct...

Страница 11: ...viewing a Data Field Press plus Field No Note the following Data will be displayed for that field number entry by entry a beep will be heard between entries and three beeps after the last No changes w...

Страница 12: ...TRY DELAY PERIMETER ARMED INTERIOR ARMED AWAY Security Code 2 Yes Yes Yes Yes STAY Security Code 3 Yes Yes Yes No INSTANT Security Code 7 Yes No Yes No MAXIMUM Security Code 4 Yes No Yes Yes DISARM Se...

Страница 13: ...hen all tests are finished and verify results with them Transmitter ID Sniffer Mode 1 Enter Master Code 3 The following will occur The keypad will display all zone numbers of wireless units programmed...

Страница 14: ...played 4a Interrupted AC power supply 4b Wire run from transformer to control is too long 4a Check transformer connection and power line circuit breaker 4b Make sure wiring run is not longer than the...

Страница 15: ...plies with Part 68 of the FCC rules On the front cover of this equipment is a label that contains among other information the FCC registration number and ringer equivalence number REN for this equipme...

Страница 16: ...e tiquette certifie que le mat riel est conforme certaines normes de protection d exploitation et de s curit des r seaux de t l communications Le minist re n assure toutefois pas que le mat riel fonct...

Страница 17: ...P 42 UP UP UP 43 UP UP 44 UP UP UP 45 UP UP 46 UP UP 47 UP 48 UP UP UP UP 49 U UP UP 50 UP UP UP 51 UP UP 52 UP UP UP 53 UP UP 54 UP UP 55 UP 56 UP UP UP 57 UP UP 58 UP UP 59 UP 60 UP UP 61 UP 62 UP 6...

Страница 18: ...ors closed doors glass partitions glass doors or windows Mechanical tampering masking painting or spraying of any material on the mirrors windows or any part of the optical system can reduce their det...

Страница 19: ...UIT BOARD HANDSET BLACK RED 1000 OHMS EOLR 1000 OHMS EOLR ZONE 1 ZONE 2 HI LO HI LO 1000 OHMS EOLR 1000 OHMS EOLR ZONE 3 ZONE 4 HI LO HI LO MAXIMUM LOOP RESISTANCE EACH ZONE 300 OHMS PLUS EOLR RESPONS...

Страница 20: ...YONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE...

Отзывы: