The charge status is indicated by 

 on the display. Charge the battery as soon as a 

low charge status is indicated by flashing charge status or LO lights up on the display 
and the scale turns off automatically. 

When charging, make sure that the adapter is at least 5 cm away from metal objects. 

If the operating time with fully charged batteries is drastically reduced, the battery must 
be replaced. In this case, please contact your local dealer or service partner. 

Make sure that the local mains voltage matches the operating voltage printed on the 
adapter. 

If you will not be using the scale for an extended period of time, disconnect the power 
supply from the mains and remove the battery to protect the scale. 

The energy transfer between the induction charger and the scale is contactless. The 
radio symbols 

 indicate the position of the transmission and reception elements (top 

side  of  the  induction  charger  and  in  the  area  of  the  induction  charging  base  of  the 
scale).  Charging  takes  place  only  when  both  elements/symbols  are  opposite  each 
other! 

The charging function is available only if the distance between the transmission and 
reception  elements  is  sufficiently  small.  It  is  therefore  necessary  to  ensure  that  the 
induction charger is properly positioned in the induction charging base. 

LED display for induction charging 

 

 

Slide the induction charger 

 into the induction 

charging base 

 and connect the charging adapter 

 to the local mains supply. 

 

The printed voltage level must comply with the 
local voltage.

 

 

The batteries in the scale will start to charge. 

The induction charger LED indicates the charge status as follows: 

Charger LED 

Battery symbol on the display 

Charge status 

LED off 

Current battery status indicator 

Charger is not connected to mains. 

LED steady green 

Evenly rolling battery symbol 

Charging is ongoing 

LED steady green 

no battery symbol 

Charging is complete or mains 
operation (without batteries) 

LED steady red 

Current battery status indicator 

Charger connected to mains, but not to 
scale. 

LED flashes red and green 

Current battery status indicator 

Sensor fault. 

 

If the scale is turned on, the charging process will be indicated by a rolling battery symbol 

 

on the display. Once charging has been completed, the rolling will stop. 

 

 

Содержание PWI30

Страница 1: ...H Co KG Hammer Steindamm 27 29 22089 Hamburg Germany 49 0 40 432776 0 Fax 49 0 40 432776 10 E mail info ade germany de Portion scale PWI30 with induction charging PWI30 190920 Rev005 UM en IMPORTANT READ CAREFULLY BEFORE USE PLEASE KEEP FOR FUTURE REFERENCE ...

Страница 2: ...harging 5 Assembling and levelling the scale 6 Using the scale 6 Switching on the scale 6 Determining weight 6 Zeroing the scale 6 Tare function 6 Setting the unit of weight 7 Switching off the scale 7 Error messages 7 Parameter settings 7 Backlight 8 Selecting the unit 8 Automatic power off in battery mode 9 Digit interval d 9 Zero offset 9 Cleaning 10 Safety information 10 Storage and transport ...

Страница 3: ...PWI30 190920 Rev005 UM en 2 Overview display 1 Spirit level 2 LCD display 3 Buttons 4 Weighing plate 5 Housing 6 Foot 7 Induction charging base 8 Induction charger 9 Charging adapter ...

Страница 4: ...rn on and off To toggle between the units of weight Display symbols EEEEEE Overload a beep sounds at the same time immediately remove the object from the weighing platform Indication that a fixed weight value has been stored which will be subtracted at each subsequent weighing process TARE symbol Indication that the scale is reset to zero Indication that the achieved weight value is stable Battery...

Страница 5: ... power off as well as the display of different units can be set or disabled To achieve precise results please read the user guide carefully and follow the instructions contained therein Inspecting the contents of the box Portion scale Load cross silicone mat and weighing plate Quick release fastener for the load cross Induction charger User manual incl declaration of conformity Safety information ...

Страница 6: ...ments symbols are opposite each other The charging function is available only if the distance between the transmission and reception elements is sufficiently small It is therefore necessary to ensure that the induction charger is properly positioned in the induction charging base LED display for induction charging Slide the induction charger into the induction charging base and connect the chargin...

Страница 7: ... three seconds The display will show ADE for two seconds and will then automatically switch to weighing mode 0 000 is shown on the display If this is not the case press the button As a result measurement inaccuracies will be compensated after turning on the scale and will be reset to zero before the actual weighing process The display now shows 0 000 and the figure indicates the zero position show...

Страница 8: ... back to the kg unit The selected unit is shown as on the display Switching off the scale To manually turn off the scale press and hold down the button for four seconds in weighing mode As soon as a beep sounds release the button and the scale will turn off Error messages Overload EEEEE display The scale overload 9d is signalled by the EEEEE display The overload must be eliminated immediately to p...

Страница 9: ... unit Use this parameter setting to disable the units of weight the display of which is not required t9 Enable On or disable Off the display of kg as the unit of weight 9 Enable On or disable Off the display of g as the unit of weight lb Enable On or disable Off the display of lb as the unit of weight oZ Enable On or disable Off the display of oz as the unit of weight Press the button to save the ...

Страница 10: ...e displayed digit interval It is recommended to leave this setting unchanged and use the button to switch immediately to the next parameter setting If it is necessary to adjust the division there are the following setting options d 1 1 g division d 2 2 g division d 5 5 g division d 10 10 g division d 20 20 g division Press the button to save the selected setting and switch automatically to the nex...

Страница 11: ...ranes on the underside that prevent the formation of condensate inside the scale To ensure protection against mechanical damage the membranes are provided with two bleed screw caps that must also be cleaned if they are soiled During assembly make sure that the membranes and seals are inserted correctly Safety information Safe operation is no longer guaranteed If the AC adapter or the power cord sh...

Страница 12: ...s etc are excluded This warranty does not cover external normal signs of wear and tear or damages caused by accident or misuse The warranty will not apply for devices that have been opened by unauthorised persons In addition the operation of the scale with damaged or missing membranes is not allowed and will void the warranty The statutory rights of the customer are not affected by this agreement ...

Страница 13: ...afe Quick release fastener for disassembly of the weighing surface Working conditions Ambient temperature 10 C 50 C Relative humidity 1 80 Functions Weighing taring units of weight kg g lb oz User friendly 2 button operation Unit conversion 1 kg 1000 g 1 kg 2 206 lb 1 kg 35 27 oz Power supply 230 V AC mains and battery operation interface free Induction charging power adapter 5 V DC 1 A high perfo...

Страница 14: ...tive 2014 30 EU regarding electromagnetic compatibility Low voltage directive 2014 35 EU RoHS Directive 2011 65 EC in the currently valid versions This declaration will lose its validity if any modification is made to the scale without our consent Hamburg January 2019 ADE Germany GmbH Co KG Hammer Steindamm 27 29 D 22089 Hamburg Manufacturer ADE Germany GmbH Co KG Hammer Steindamm 27 29 D 22089 Ha...

Страница 15: ...PWI30 190920 Rev005 UM en 14 ...

Страница 16: ...15 PWI30 190920 Rev005 UM en Distributor ...

Отзывы: