Set zero 

 
By using the 

Zero 

key eventual irregularities occurred after start up the scale can be compensated by 

setting the display back to zero. 
 

Hold function 

 
Press the 

Hold

 key in case of unstable readout which might occur in case of too heavy agitation on 

the platform. The scale will hold the result displayed. After leaving the scale the fixed weight is still 
displayed and can be noted. Deactivate the HOLD function by pressing the key again. 
 
 

Unit function 

 
By using the 

Units

 key you may select the weighing mode (kg, lbs, st). 

 
 

Cleaning, Maintenance and Re-approval 

 

Cleaning 

 
Before cleaning make sure the scale has been disconnected from the socket. 
For cleaning just use a damp cloth or common disinfection products. 
Do not use any aggressive cleaning fluids. 
Make sure no water or cleaning fluid penetrates the scale. 
 

Service 

 
Display indication 

Lo

 

Recharge the power-pack by connecting the mains adapter to the display. 

Display indication 

ErrL

  Check correct positioning of the scale (see chapter installation & use of scale) 

and make sure the scale is completely unloaded. 

Display indication 

Err

  Function test does not automatically lead to `0.00´. Try 

zero

 setting key. If 

display still indicates Err the scale needs calibration. Please contact your local 
dealer or service partner. 

Display indication 

ErrP

  Severe failure of weighing system. Please contact your local dealer or service 

partner. 

 

Safety instructions 

 
Do NOT use the scale  
 

  If the mains adapter shows visible damages 

  If mains adapter is not working properly 

  After long storage in humid places 

 
In those cases contact your local dealer or service partner. 
 

Storage and Transport 

 
Keep all original parts and pieces for an eventual sending back of the scale in order to avoid any 
possible damage during transport which automatically leads to no warranty. 
 
Disconnect all cables before transport to avoid unnecessary damages. 

Содержание M50010

Страница 1: ...Operating Manual Electronic Wheelchair Scale class III approved M50010 ADE GmbH Co Hammer Steindamm 27 29 22089 Hamburg GERMANY 49 40 432776 0 Fax 49 40 432776 10 E mail info ade hamburg de...

Страница 2: ...d scales are imperative 4 Connecting additional equipment 4 Quality check 4 EC type approval 4 Use of the scale 5 Weighing 5 Body Mass Index BMI 5 Evaluation of the Body Mass Index 5 Tare functions 5...

Страница 3: ...y to be tared HOLD To fix the weighing result BMI To evaluate the BMI Body Mass Index SEMI AUTO TARE To tare a value automatically UNITS To change the weighing unit CLEAR Clear indication ENTER Confir...

Страница 4: ...Manual including Certificate of Conformity Attention Carefully check identity of the serial numbers on the platform and the indicator which is mandatory for medical use of the scale Power Supply of t...

Страница 5: ...pean Directive 93 42 EEC for medical devices and declares the conformity as per this Directive Due to the certification as per ISO 9001 2000 the high standards for Research Development Manufacturing S...

Страница 6: ...BMI is calculated and displayed Evaluation of the Body Mass Index BMI below 18 The patient is not showing enough weight Control nutrition to put on weight BMI between 18 and 20 The patient is slightly...

Страница 7: ...Display indication Lo Recharge the power pack by connecting the mains adapter to the display Display indication ErrL Check correct positioning of the scale see chapter installation use of scale and m...

Страница 8: ...or any warranty claim customer service and spare parts Re approval For re approval of the scale as per the national directives governing the standards for non automatic scales as well as for medical d...

Страница 9: ...i folgende direktiver 90 384 EEC om ikke automatiske vekter 93 42 EEC om medisinske proukter og den europeiske standarden DIN EN 45501 FIN on tyyppihyv ksynt todistuksessa kuvatun raken nemallin muka...

Страница 10: ...9 050100 Rev000 M50010...

Страница 11: ...050100 Rev000 M50010 10...

Страница 12: ...11 050100 Rev000 M50010...

Отзывы: