Display
Description
Fig. 1-1 Indicator and operating controls
No. Name
Description
1
Display
LCD display for weight, mode, settings and configuration information.
2
Battery charge level
Status indicator for the current battery charge level.
3
Switching points 1 & 2 In program mode: Status indicator for switching points 1 & 2.
4
BMI status indicator
(HI, OK, LO)
Status indicator of the automatic BMI (Body Mass Index) evaluation.
5
Net status indicator
LCD on - net weight is being displayed.
LCD off – gross weight is being displayed.
6
Status indicator
The scale is at zero level.
7
Hold – button
Activates the hold function.
8
On/off, zero – button
On and off switch and re-set of the display.
9
Tare- button
Activate/ deactivate the tare function.
10
Preset tare – button
Press briefly to access the tare function.
Press for a long period to enter and save the tare value.
11
BMI – Button
Enter to proceed with BMI mode.
12
Units – Button
Switch button between primary and secondary units. Not available for CE
approved class III scales
13
Number pad
Figures 0-9, Clear, Enter and Navigation functions: Key 6 menu direction
to the right; Key 4 menu direction to the left; Key 8 menu direction down;
Key 2 menu direction up. For better understanding see Pic. 1.1 the blue
arrows. Used to navigate through menus, to select numerical values and
to increase or lower the value.
Special function:
"0" key
In weight mode, you can change between gross and net weight using
figure "0" (if any weight have been tared off).
"Enter" key
Function in weight mode: "Print" if printer has been connected.
14
Standstill status indica-
tor (14)
:
The scale is at a standstill. The weight is stable with no movement. This
is mandatory for functions like reset, print and tare.
15
“Hold”
If displayed is the hold function is activated
17
“kg”
If displayed is the weight is displayed in kilograms
“g”
If displayed is the weight is displayed in grams
Connecting additional devices
Printer, PC or remote-display could be connected by the RS-232 interface. For connection of additional devic-
es kindly ask your local representative or authorized ADE dealer for further instructions.
Housing and connections
The connections to mains adapter, serial port and to the load cells are located at the back of the ADE display.
The set-up switch to start the configuration mode is underneath the housing. It is protected by a cover plate
and secured by a screw (not shown in Fig. 2-1).