Diagram 1
External Grille
Diagram 5
5. Remove external grille by gently levering the top out with a small screwdriver and
remove the four pozidrive screws and separate the two halves. Hold against the
outside wall directly over the duct and drill and plug the fixing holes. Screw the grille
chassis to the wall and refit the grille. It is important to make sure that the two fixing
holes are one above the other to allow the lugs on the grille to fit properly into their
slots the right way up.
6. Remove the front grille concealing 2-fixing screws which secure the front grille
assembly to the main chassis. Remove these screws then carefully separate the two
halves.
Hold the body over the hole, first ensuring that the fan is level then mark four of the
six fixing holes available (one in each corner). Drill and plug these holes. Screw the
fan to the wall and refit the front grille and replace screw caps.
7. Make the electrical connection as described in Paragraph 3.
If in any doubt call a qualified electrician.
8. Ratings as marked on fan label. T. Max 40
o
C
NOTE:
Do not install within a shower cubicle (Use our range of shower fans) or anywhere else
where there is a high risk of the fan being sprayed with water.
Fan to be fitted a minimum 2.3 metres from the floor.
Diagram 2
Rear of Fan with
grille removed
AUTO SHUTTER
INTERNAL FLAPS
AUTO GUARD
FIXING SCREWS
COVER
SCREWS
CABLE ENTRY
BACKCOVER
WITH GRILLE
THROUGH GLASS
FIXING TO FAN
CHASSIS
WINDOW
BACK COVER WITH GRILLE
CABLE ENTRY
AUTO GUARD FIXING SCREWS
AUTO SHUTTER INTERNAL
FLAPS
COVER SCREWS
WINDOW
THROUGH GLASS FIXING
TO FAN CHASSIS
THROUGH WALL FIXING
4mm - 32mm Glass
Cable Entry
Cable
Entry
1.5A Two Core Cable
Cable Entry
IN
OUT
O
1.5m 5A Two Core Cable
D
B
Cable
Entry
Pull
Cord
C
A
THROUGH GLASS FIXING
SIDE ELEVATION
THROUGH GLASS
FRONT ELEVATION
4mm - 32mm Glass
Cable Entry
Cable
Entry
1.5A Two Core Cable
FRONT ELEVATION
Cable Entry
IN
OUT
OUT
IN
1.5m 5A Two Core Cable
D
B
A
A
A
B
A
Cable
Entry
Pull
Cord
C
C
CAUTION
Precautions must be taken to avoid the back-flow of gases into the room from the open
flue of gas or other open-fire appliances when mounted in outside windows or walls.
Key to dimensions / mm
230mm
300mm
A B C D
286 125 25 230
362 145 29 300
Diagram 4
Diagram 3
IMPORTANT :
Switch off mains supply before making any electrical connections. Installation
must be supervised by a qualified electrician.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance. Precautions must
be taken to avoid the back-flow of gases into the room from the open flue of gas
or other open-fire appliances when mounted in outside windows or walls.
Maintenance :Switch off mains supply and isolate the fan before carryout any
maintenance. The front cover can be removed and cleaned with warm soapy
water or polish. The fan impellor and the inside of the fan can be cleaned using a
warm damp cloth, care must be taken not to make the electrical connections wet.
It is recommended to check the electrical connections annually.