Addvent AVX 230 Series Скачать руководство пользователя страница 2

Diagram 1

External Grille

Diagram 5

5. Remove external grille by gently levering the top out with a small screwdriver and

remove the four pozidrive screws and separate the two halves. Hold against the

outside wall directly over the duct and drill and plug the fixing holes. Screw the grille

chassis to the wall and refit the grille. It is important to make sure that the two fixing

holes are one above the other to allow the lugs on the grille to fit properly into their

slots the right way up. 

6. Remove the front grille concealing  2-fixing screws which secure the front grille

assembly to the main chassis. Remove these screws then carefully separate the two

halves.

Hold the body over the hole, first ensuring that the fan is level then mark four of the

six fixing holes available (one in each corner). Drill and plug these holes. Screw the

fan to the wall and refit the front grille and replace screw caps.

7. Make the electrical connection as described in Paragraph 3.

If in any doubt call a qualified electrician.

8. Ratings as marked on fan label. T. Max 40

o

C

NOTE:

Do not install within a shower cubicle (Use our range of shower fans) or anywhere else

where there is a high risk of the fan being sprayed with water.

Fan to be fitted a minimum 2.3 metres from the floor.

Diagram 2

Rear of Fan with

grille removed

AUTO SHUTTER

INTERNAL FLAPS

AUTO GUARD

FIXING SCREWS

COVER

SCREWS

CABLE ENTRY

BACKCOVER

WITH GRILLE

THROUGH GLASS

FIXING TO FAN

CHASSIS

WINDOW

BACK COVER WITH GRILLE

CABLE ENTRY

AUTO GUARD FIXING SCREWS

AUTO SHUTTER INTERNAL

FLAPS

COVER SCREWS

WINDOW

THROUGH GLASS FIXING

TO FAN CHASSIS

THROUGH WALL FIXING

4mm - 32mm Glass

Cable Entry

Cable

Entry

1.5A Two Core Cable

Cable Entry

IN

OUT

O

1.5m 5A Two Core Cable

D

B

Cable

Entry

Pull

Cord

C

A

THROUGH GLASS FIXING

SIDE ELEVATION

THROUGH GLASS

FRONT ELEVATION

4mm - 32mm Glass

Cable Entry

Cable

Entry

1.5A Two Core Cable

FRONT ELEVATION

Cable Entry

IN

OUT

OUT

IN

1.5m 5A Two Core Cable

D

B

A

A

A

B

A

Cable

Entry

Pull

Cord

C

C

CAUTION

Precautions must be taken to avoid the back-flow of gases into the room from the open

flue of gas or other open-fire appliances when mounted in outside windows or walls.

Key to dimensions / mm

230mm

300mm

A B C D

286  125   25    230

362  145   29    300

Diagram 4

Diagram 3

IMPORTANT : 

Switch off mains supply before making any electrical connections.  Installation

must be supervised by a qualified electrician.

This appliance is not intended for use by persons (including children) with

reduced physical, sensory or mental capabilities, or lack of experience and

knowledge, unless they have been given supervision or instruction concerning

use of the appliance by a person responsible for their safety. Children should be

supervised to ensure that they do not play with the appliance. Precautions must

be taken to avoid the back-flow of gases into the room from the open  flue of gas

or other open-fire appliances when mounted in outside windows or walls.

Maintenance :Switch off mains supply and isolate the fan before carryout any

maintenance. The front cover can be removed and cleaned with warm soapy

water or polish. The fan impellor and the inside of the fan can be cleaned using a

warm damp cloth, care must be taken not to make the electrical connections wet.

It is recommended to check the electrical connections annually.