(Alarm transmission)
Alarm protocols 

 SIA (level 1 to 3) reference SIA DC-03-1990.01(R2003.10)

 

 

Contact ID reference SIA DC-05-1999.09

 

 

FF (Scancom)

 

 

Robofon (dial capture only)

 

 

Telim (dial capture only)

 

 

CESA (dial capture only) 

Tamper detection 

Dial capture interface

  

Serial Interface

 

 

Pin inputs

Fault reporting to 

Transmission interface/path fault

Monitoring Center 
Relay outputs (solid-state)
Maximum operating voltage 

28V DC 

Maximum current rating 

100mA DC 

Power supply
Supply voltage 

5-28 VDC

Typical current 

80mA @ 12VDC, 40mA @ 24VDC

Maximum current 

1A @12VDC

Recommended external PSU 

                12V DC 1A 12 Watt

  

Environmental
Operating temperature range 

-10°C to 55°C

Operating humidity range 

95% max., non-condensing

Weights and dimensions
Physical dimensions 

87mm x 55mm x 16mm

Terminal weight 

85 grams (with wire harness)

Fully packaged weight 

200 grams

(when external to alarm panel 

enclosure and configured 

accordingly)

 Note:

Cabling must not exceed 3 meters

 Note:

Cabling must not exceed 3 meters

Содержание IRIS-4 50

Страница 1: ...AIRBORNE DC MEDIUM Hurtigmanual Snabbguide IRIS 4 50 Quick Installation and Maintenance Guide...

Страница 2: ...ting pads Adhesive mounting pad Cable tie wrap for mounting Signal strength default button USB micro connector Cable harness loom with color coded identification Cellular antenna connection Terminal A...

Страница 3: ...nitoring centre IP address LED COLOUR DISPLAY REASON Terminal status green On steady No faults Flashing on 0 5s off 0 5s One or more fault present Cellular yellow On Cellular OK will flicker off for 0...

Страница 4: ...is expected to be available Do not fix the antenna until after the terminal has been powered up and the cellular signal strength can be checked see section Connecting Power below 6 INSTALLATION 6 4 Co...

Страница 5: ...can be configured using the IRIS Toolbox software application on a PC connected to the terminal with a USB cable Please use Toolbox software version 4 7 1 or later To reset to factory default setting...

Страница 6: ...utbound 53165 Alarms and Polling 51292 Diagnostic and Reflashing 10001 Upload Download Alarm transmission Interface to ISA or IRIS Management Suite via Monitoring Center EN 50136 2 pass through mode D...

Страница 7: ...um operating voltage 28V DC Maximum current rating 100mA DC Power supply Supply voltage 5 28 VDC Typical current 80mA 12VDC 40mA 24VDC Maximum current 1A 12VDC Recommended external PSU 12V DC 1A 12 Wa...

Страница 8: ...have the following safety classifications Power Interface SELV for connection to a DC supply Inputs SELV for connection to alarm output pin CONFORMANCE European Directives The terminal complies with t...

Отзывы: