Unit on/off and LED 

 

 

 

 

 

 

 

 

 

 

6

 

Final test 

Send a SMS with the text: STAT to the GSM number of the unit. The following reply must be received 

Reply 

Meaning 

Version=

Blackbird 0.11

 

Software version 

OPT2 

Firmware Version in OPT2 board (PRO version only) 

FW=

0.35 

Firmware program version 

NodeID=

3090818019

 

The serial number (S/N) of the unit  

BattV=

3987

 

Current battery voltage in mV 

 typically between 3650mV and 4200mV 

Runtime= 

3239

 

Number of seconds that the unit has been on 

MCC=23802 

Provider network code 

Signal= 

81

 

GSM signal strength 

 must be between 100 and 50. Low is best 

Sat=

11

 

No of satellites 

HDOP=

10

 

GPS HDOP value GPS quality 

Ichg=

127.6

 

Charging power 

Bt=35.60 

Battery temperature 

Odo 

Current Odometer value 

Vt 

0/1 valid time or not on unit   

All values stated after = are examples.  

 

ON/OFF button 

When the unit is off it must 

not

 be 

connected to a power source. 

Press button for 5 seconds till yellow lamp 
starts to flash differently. 

Release the button and press it briefly 
again. Turn off the unit. 

Yellow. System service 

Constant light: System starts. 

1 flash: System is on, but not connected 
to GSM data. 

2 fast flashes: System is on server. 

Blue. GPS receiver 

1 quick flash: No GPS satellites received 

1 long flash followed by a number of quick 
flashes: Receiving GPS. The number of 
short flashes states the number of 
satellites being received. 

Red. Power/Charging status 

Constant light: 

Fully uploaded 

1 flash: battery low level 

2 flashes: Charging 

 

Green. GSM service 

Flashing sporadic: OK 

Flashing constant: SIM card error 

USB-input for charger 

230 V charger and 
12/24 V cigarette charger 
available as option. 

Installation inputs 

Yellow 

Blue 

Red 

Green 

Содержание Asset Light

Страница 1: ...Version 2 3 2017 01 26 PEP FB Asset Light Asset Pro AddSecure Asset Installation Guide ...

Страница 2: ... LED 7 6 Final test 7 7 Carrier Transicold 8 7 1 Datalogger Datacold 500 600 and EuroScan X2 8 7 1 1 Mounting 8 7 1 2 Connection 8 7 1 3 Ignition Connection 9 7 1 4 Configuration of datacold 500 600 and EuroScanX2 9 7 1 5 System configuration 9 8 ThermoKing 10 8 1 Datalogger DAS SR2 CargoWatch 10 8 1 1 Serial RS 232 connection to CargoWatch 10 8 1 2 Ignition Connection 10 8 1 3 Configuration of da...

Страница 3: ...sistant auto fuse on the white wire to permanent supply Place the fuse as close to the power source as possible to protect the vehicle To obtain a water proof installation mount the supplied four locking devices Mount the unit on a suitable place where it is protected from water Never clean the unit with a high pressure cleaner The wire output must face downwards When attaching the power multi con...

Страница 4: ...temperature sensor 10 Blue Not used Digital Output 11 Grey Not used Digital Input 12 Brown Terminal 15 ignition Ignition has to be connected if there is no ignition signal in the vehicle connect the cable to terminal 30 24 Volt 13 Black Terminal 31 ground Battery minus terminal 14 White Terminal 30 24 Volt Constant supply between 10 Volt to 60 Volt ...

Страница 5: ...Used for ThermoKing Carrier 3 Green RX RS 232 Used for ThermoKing Carrier 4 Black Whit e CAN Not used 5 Red White CAN Not used 10 Blue Outout Not used 11 Grey Input 2 Not used 12 Brown Terminal 15 ignition Ignition has to be connected if there is no ignition signal in the vehicle connect the cable to terminal 30 24 Volt 13 Black Terminal 31 ground Battery minus terminal 14 White Terminal 30 24 Vol...

Страница 6: ...e The cable is with silicone outer jacket and Teflon inner jackets so it is durable in high and low temperatures The capacity between wires must not be higher than 10 15 pF per meter Total length added for all sensors is maximum 20 meters 3 2 Temperature sensor PRO version only Where to mount the temperature sensor Possible places to mount the temperature sensor At the air intake of the cooling sy...

Страница 7: ...d they must be parallel mounted White core to white core and brown core to brown core Wires may be extended All soldering must be isolated 4 Wireless Sensors When mounting wireless sensors the Asset unit is not allowed to be placed in the trucks cabin The Asset unit should be mounted on the trailer or cargo unit ...

Страница 8: ...Asset unit the range will vary e g the Asset unit cannot be mounted in the trucks cabin and communicate with the sensor Note Write down the serial number of the sensor located on the back of the sensor A wireless temperature sensor consists of only one part the Sensor Depending on materials between and around the sensor and Asset unit the range will vary e g the Asset unit cannot be mounted in the...

Страница 9: ...alid time or not on unit All values stated after are examples ON OFF button When the unit is off it must not be connected to a power source Press button for 5 seconds till yellow lamp starts to flash differently Release the button and press it briefly again Turn off the unit Yellow System service Constant light System starts 1 flash System is on but not connected to GSM data 2 fast flashes System ...

Страница 10: ...ld 7 1 Datalogger Datacold 500 600 and EuroScan X2 7 1 1 Mounting The Asset Pro can be mounted on the rear of the datalogger 7 1 2 Connection It mush flush with the edges Make sure that there is room for the printer cable ...

Страница 11: ...ot used the brown wire must be connected to the white wire Datacold 12 volt 7 1 4 Configuration of datacold 500 600 and EuroScanX2 The configuration of the datacold must be done before the Lommy works Hold the green button for 2 seconds The display shows Enter PIN Factory code is 1111 press 4 times the blue Select menu 11 with the arrow keys Datacold 500 Com 1 should be Thirdparty Datacold 600 Com...

Страница 12: ...ht It will then show if the trailer is connected to a truck with ignition on Light turned on Trailer and datalogger has separated ground Remember to mount the 1 kohm resistor R2 On trucks the ground is normally common and the resistor is not needed Can also be connected to the ignition of the refrigeration unit and used to indicate is the cooler is running If this option is not used the brown wire...

Страница 13: ...11 8 2 i Box ...

Страница 14: ...Datalogger To connect to a HUK you will need a male DB9 connector Power is connected as usual PINOUT Asset DB9 Green 2 Orange 3 Black 5 Jumper between 7 8 10 System configuration See the document Asset configuration AddSecure ...

Отзывы: