Addonics Technologies ST55HPMXA Скачать руководство пользователя страница 5

www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST)   

Phone: 408-453-6212 

Email: www.addonics.com/support/query/

Setting or Modifying the RAID Mode Using the JMicron 

HW RAID Manager Utility Program:

1. 

For Windows users, install the JMicron HW RAID Manager located on the  

 

SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This  

 

manager can be use to create and monitor the status of the RAID volume.

 

It is recommended to use the default factory RAID DIP switch setting when  

 

using the JMicron HW RAID Manager.

2. 

Modify the RAID mode on the 5-port HPM-XA using DIP switch

 

Recommended to be used on operating system without JMicron HW RAID  

 

Manager support like Linux, Mac & Solaris. Windows users can also use the  

 

procedure below.

Note: Steps A to D need to be performed each time the raid mode is modified.

 

a. 

Set the DIP switch as shown below. 

 

 

b. 

Press the RAID setting button with a ball point pen.

 

c. 

While pressing the RAID setting button turn on the system power  

 

 

where the HPM is connected. The buzzer will sound while holding the  

 

 

RAID setting button. Release it after at least 5 seconds for hardware  

 

 

initialization. A single beep will be heard to indicate initialization is  

 

 

completed. The above steps act as a reset.

 

d. 

Power off the system power.

1      2      3      4      5

SW1

BZS  EZ    M2   M1   M0

OFF

OFF

OFF

OFF

OFF

Содержание ST55HPMXA

Страница 1: ...o get your unit functioning properly please have your product information ready and contact Addonics Technical Support at Hours 8 30 am 6 00 pm PST Phone 408 453 6212 Email http www addonics com suppo...

Страница 2: ...the hard drives into the optional mounting brackets or slide in 5 25 devices into the tower Other types of enclosures like the 5SA disk array can also be mounted Mounting one 5SA disk array and anoth...

Страница 3: ...de Raid Mode 1 2 3 4 5 Individual Drive Factory Default OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON ON OFF OFF ON OFF OFF OFF ON ON 0 1 and 10 3 5...

Страница 4: ...ual drive mode is ENABLED M0 M2 Note When the default factory RAID setting is used independent drive configuration and optical drive are supported only when connecting to controllers with Silicon Imag...

Страница 5: ...he 5 port HPM XA using DIP switch Recommended to be used on operating system without JMicron HW RAID Manager support like Linux Mac Solaris Windows users can also use the procedure below Note Steps A...

Страница 6: ...BLED EZ function is DISABLED 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 RAID 0 Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 Clone Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 RAID 1 RAID 10 Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 Large Mo...

Страница 7: ...s connected to an eSATA host controller card on the RAID BIOS the raid array will display as Addonics H W RAID0 if setup as a RAID0 array k If booted into Windows in Disk Drives under Device Manager t...

Страница 8: ...are For a 2 drive RAID1 with spare Drives connected to SATA ports 1 4 belong to the active RAID1 array and drive connected to port 5 is the spare B When will rebuild action start When the raid fails a...

Отзывы: