IRON GENIE MASTER PROGRAMMING GUIDE
Press the Up or Down Arrow Buttons to enter the Time of Day
Programming Mode, Set the Time of Day Display to 12:01 P.M.
Press the Extra Cycle Button once to exit the Time of Day Programming
Mode.
With the Time of Day Display set to 12:01 P.M., Push and hold the Up
and Down Arrow Buttons for 7 seconds.
Press the Extra Cycle Button once to advance to next parameter.
1.
DF - GAL - US Gallon Display Format
2.
VT - dF1b – Down flow, Single Backwash
3.
CT - tc - Time Clock Control
4.
NT - 1 - Single Tank System
5.
DO - 3 - Day Override
6.
RT - 12:30 A.M. - Time of Regeneration
7.
BW - 0 - 0 Minute Backwash
8.
BD - 60 - 60 Minute Air Recharge
9.
RR - 1 – 1 Minute Rapid Rinse
10.
BF – OFF – Brine fill turned off
11.
Exit Master Programming and Return Valve to Service Display