Rack Mount: RMK12, RMK17
Quick Start
Using the RMK17 Adder rack mount
(see over for RMK12)
1 Install the empty rack mount into your 19” rack frame and fully secure it.
2 Place compatible modules into the three bays of the rack mount so that their rear panels butt up
against the small pegs located on each of the side walls.
3 Locate the supplied thumbscrews and spacers.
4 Insert the thumbscrew through the spacer; then insert into the small hole at the
end of a divider
(A)
.
5 Gently tighten the thumbscrew so that the spacer engages with
the inner edges of the modules that are either side of the
divider to hold them in place
(B)
.
6
Repeat steps 4 and 5 for the other thumbscrew and
spacer.
7 Place the power adapters in the rear section of the rack
mount and connect them to their respective modules.
8 Make all other necessary connections to the modules.
(A)
(B)
© 2021 Adder Technology Limited
All trademarks are acknowledged.
Part No. MAN-QS-000067_V1.0
www.adder.com
RMK17-BP
blanking plate
Using a blanking plate when a single module is installed
In order to maintain suitable cooling airflow, if only two modules are installed within the rack
mount, you are recommended to install an optional blanking plate: RMK17-BP
Note: The outer edge of the blanking plate needs to overlap the ears of the rack mount itself,
so you need to either install the blanking plate before the tray is installed or briefly remove the
mounting bolts on the blanked side (while supporting the weight of the tray) to allow the blanking
plate to be put in place.