14
Power in connection
The AdderView CATx unit is
supplied with a single 30W power
adapter which is sufficient to supply
any configuration of the unit. The
AdderView CATx IP unit has two
power input sockets to allow an
auxiliary (redundant) power adapter
to be connected. There is no on/off
switch on the unit, so operation
begins as soon as a power adapter
is connected.
Note: AdderView CATx units require a heavy duty power adapter at either or
both power input connectors. Use only the adapter supplied with the unit or
available under Adder part numbers: PSU-IEC-5V4A (for AdderView CATx) or
PSU-IEC-5V6A (for AdderView CATx IP). Do not use the standard 10W adapters
that are supplied with other Adder products, such as the X100.
To connect the power supply
1 Attach the output lead from the power adapter to the
MAIN PWR IN
socket
on the rear panel of the AdderView CATx.
2 Connect the IEC connector of the supplied country-specific power lead to
the socket of the power adapter.
3 Connect the power lead to a nearby main supply socket.
4 Repeat steps 1 to 3 for the auxiliary power adapter (using the
AUX PWR IN
socket), if a backup supply is required.
Note: Both the AdderView CATx and its power supply generate heat when in
operation and will become warm to the touch. Do not enclose them or place
them locations where air cannot circulate to cool the equipment. Do not operate
the equipment in ambient temperatures exceeding 40 degrees Centigrade. Do
not place the products in contact with equipment whose surface temperature
exceeds 40 degrees Centigrade. Using two power supplies will ensure that each
power supply takes less load and run at a correspondingly cooler temperature.
AdderView CATx
rear panel
output lead from
power adapter
Содержание AdderView CATx AVX4016