Further information

Troubleshooting

If you experience problems when installing or using the X2-Series extender 
modules, please check through this section for a possible solution. If your 
problem is not listed here and you cannot resolve the issue, then please refer to 
the ‘Getting assistance’ section.

Video image at the REMOTE module is distorted or shadows appear to 
the right of displayed objects.

Adjustments are required to compensate for the length of the twisted pair cable 
being used. If video problems persist:

•  Please refer to the ‘Image controls - sharpness and brightness’ section in the 

‘Special Configuration’ chapter.

•  If the overall video image is ‘fuzzy’ and/or has coloured shadows you 

may need to make skew adjustments (X2-Silver and X2-Gold only). This 
procedure allows you to finely tune the red, green and blue video signal 
timings to overcome most colour separation problems. Please refer to the 
‘Skew adjustment’ section in the ‘Special Configuration’ chapter.

No video image is received at the REMOTE module.

•  Check that the power/activity indicators are lit on the LOCAL and REMOTE 

modules - if they are not, then there is a power problem. The LOCAL 
module gains its power either from the computer’s keyboard socket or by 
using an optional power supply. 

   When keys are pressed or the mouse is moved, check that the indicators 

flicker – if they do not respond then there could be a twisted pair link 
problem or a problem with one of the modules.

•  Check that the Category 5 (or higher) cable is wired correctly as per the 

diagram in the ‘Skew adjustment’ section in the ‘Special Configuration’ 
chapter.

•  If possible, try using an alternative twisted pair connection between the 

modules.

•  If the sharpness control is set too high, the monitor may not be able to 

display a picture. Try reinstating the factory default sharpness settings. 
Please refer to the ‘Image controls - sharpness and brightness’ section in the 
‘Special Configuration’ chapter.

•  Temporarily disconnect the video link to the LOCAL module, connect a 

monitor directly to the computer video port and check for a correct video 
image output.

The keyboard indicators are flashing between the Caps Lock and the 
Num Lock/Scroll Lock and the computer does not respond to any key-
board or mouse inputs.

•  The modules are currently locked and require a valid password to be 

entered. Please refer to the section ‘Locking and unlocking the system’ for 
details. 

Power is applied via the power supply but the REMOTE module opera-
tion has stopped.

•  Each module has an internal automatic cut-out fuse to protect against 

power surges. To reset, remove power from the module for one second and 
then reconnect.

The on-screen mouse pointer does not respond to mouse movements

•  The mouse connection may have been interrupted. Either, reboot the 

system and re-power the REMOTE module power supply, or try using the 
mouse restoration command. Please refer to the ‘Hot plugging and mouse 
restoration’ section in the ‘Special Configuration’ chapter.

Sound from the microphone cannot be heard or is very quiet

•  Check the setting of LOCAL switch 3 - if a microphone is connected at the 

REMOTE module, the switch should be set OFF.

Sound input from the stereo line input is distorted (‘tinny’ sounding) and 
only one channel is working 

•  Check the setting of LOCAL switch 3 - if a stereo line input is connected at 

the REMOTE module, the switch should be set ON.  

Getting assistance

If you are still experiencing problems after checking the list of solutions in the 
Troubleshooting section then we provide a number of other solutions:

•  

Adder Technology website 

– 

www.adder.com

   Check the Support section of our website for the latest solutions.

•  

Email 

[email protected]

•  

Fax  

in the UK: 

01954 780081

    

in the US:  

+1 888 275 1117

•  

Phone  

in the UK:  

01954 780044

    

in the US:  

+1 888 275 3337

SECT 5

Содержание AdderLink X2 Dual Access

Страница 1: ...T O L O C A L P O W E R www adder com T O L O C A L P O W E R www adder com REMOTE www adder com T O L O C A L P O W E R AdderLink X2 Series Remote Extenders ...

Страница 2: ...using and exiting configuration mode 11 Password setting 12 Password override 12 Hot plugging and mouse restoration 13 Which restore setting do I use 13 Microsoft and Logitech specific mouse settings 13 Image controls sharpness and brightness 14 Skew adjustment X2 Silver and X2 Gold only 15 Miscellaneous settings 16 Flash upgrade 17 Stage A Download the upgrade files 17 Stage B Create a startup di...

Страница 3: ...harpness and brightness settings to suit your own preferences Additionally the X2 Silver and X2 Gold models also feature Skew adjustment to counteract the effects of uneven lengths of twisted pair cables that are used to carry the video signals This table indicates the functional differences between the three variants within the X2 Series X2 X2 Silver X2 Gold Keyboard extension Video extension Mou...

Страница 4: ...ction to RS232 serial device Connection to LOCAL module Power and signal activity indicator L O C A L w w w a d d e r c o m T O R E M O T E P O W E R LOCAL X2 module Connection from computer RS232 serial port Optional power supply connection Switch bank to determine certain modes and functions Connection to REMOTE module Multi cable connection from computer Power and signal activity indicator Mult...

Страница 5: ...ut on the REMOTE unit LOCAL Switch 4 OFF Normal operation ON Suspend operation and reset the LOCAL module Use this setting momentarily to produce the same effect as removing and restoring power if incorrect operation has occurred Return the switch to the OFF position to allow normal operation to continue Installation The installation of the X2 Series extender set is straightforward and can best be...

Страница 6: ...e REMOTE module that the next key to be pressed is a special configuration command for the module and is not to be passed to the computer system 2 OFF 3 OFF Hotkeys CTRL and SHIFT 2 OFF 3 ON Hotkeys ALT and SHIFT 2 ON 3 OFF Hotkeys CTRL and ALT 2 ON 3 ON Hotkeys disabled REMOTE Switch 4 This switch is reserved for future use Note When shipped all switches are set in the OFF positions and this will...

Страница 7: ...1 ON 4 2 3 Rack mount Note The module switches are not accessible once it is inserted into the rack therefore check all settings before insertion 1 Place the rack securing plate available as a separate kit onto the front of the module and secure it with the two countersunk screws 2 Orient the module on its side so that its labelled face is the correct way up and the securing plate is facing away f...

Страница 8: ...or MIC Pink or maroon Serial cable connection The X2 Series extender modules offer the option to attach an RS232 serial device such as a touch screen input via the remote link The link supports software or hardware handshaking up to a maximum baud rate of 56Kb s To make the serial connection between the LOCAL module and your computer system use the supplied serial link cable 1 Attach male connecto...

Страница 9: ... connector from the twisted pair cable link into the socket marked TO LOCAL 2 Attach the output connector of the power supply to the socket at the front edge of the REMOTE module labelled POWER 3 If a serial connection is to be used attach the lead from your serial device to the 9 way male connector on the REMOTE module labelled Power supply connection 1 Insert the IEC connector of the supplied po...

Страница 10: ...AL switch 3 ON stereo line in 1 Connect the microphone or stereo line input plug to the REMOTE module socket labelled Note Ensure that the setting of switch 3 on the LOCAL module matches the input to this socket OFF microphone ON stereo line input 2 Connect the speaker plug to the socket labelled Note When the X2 Gold REMOTE module is rack mounted the audio connections must be made after the modul...

Страница 11: ...dules offer a viable security system to deter unauthorised use Once a password has been set a simple key sequence allows the system to be quickly and securely detached from its peripherals Only the correct password will reconnect the remote and local modules To lock the system 1 First set a password For further details please refer to the Password setting section in the Special configuration chapt...

Страница 12: ...e also needed for computer tasks you can change them for another combination using switches 2 and 3 on the REMOTE module 2 OFF 3 OFF Hotkeys and default setting 2 OFF 3 ON Hotkeys and 2 ON 3 OFF Hotkeys and 2 ON 3 ON Hotkeys disabled Entering using and exiting configuration mode To enter and use configuration mode 1 Simultaneously press the currently configured hotkeys by default and along with Th...

Страница 13: ...d unlocking the system section in the Installation and operation chapter Password override This mode allows you to override the password that has been set at the REMOTE module and place it into configuration mode so that a new one may be set This feature is particularly useful when passwords have been lost or forgotten To override the REMOTE password 1 Remove power from the REMOTE module 2 With po...

Страница 14: ...usually state that it is an Intellimouse on its underside label Recognising an Intellimouse driver Before hot plugging your X2 Series extender modules or afterwards using only keyboard control access the Windows Control Panel and select either the Mouse option on Windows NT 2000 and XP or the System option on Windows 95 98 ME Look for the name of the driver which will usually include the words PS ...

Страница 15: ...equence The speed of the sequence indicates the level of the sharpness adjustment currently applied the slower the rate the lower the level of sharpness being applied 2 While viewing the displayed high contrast screen image use the following keys to adjust the controls High contrast black character on white background Black or bright white shadow on the right indicates the need for sharpness adjus...

Страница 16: ...ly Skew affects the horizontal placement of the colours and using this pattern it is much easier to discover which if any colours are being adversely affected by the twisted pair cable run 3 Simultaneously press the hotkeys by default and along with to enter configuration mode The three keyboard indicators Num Lock Caps Lock and Scroll Lock will now begin to flash in sequence 4 As appropriate pres...

Страница 17: ...em is running an application that can display typed keys as screen characters e g a word processor or Windows Notepad The current firmware version will be written to the application in the form of the letter V followed by three numbers for example V201 means version 2 01 Reset all configuration options to default states Returns all user configurable options to the settings that are installed at ma...

Страница 18: ...ropriate one X2GDLxxx HEX X2SLLxxx HEX X2STLxxx HEX these are the firmware files for the X2 Gold X2 Silver and X2 LOCAL modules respectively X2GDRxxx HEX X2SLRxxx HEX X2STRxxx HEX these are the firmware files for the X2 Gold X2 Silver and X2 REMOTE modules respectively Where xxx is the upgrade version number Now please follow Stage B Stage B Create a startup diskette For this stage you will need a...

Страница 19: ... keyboard port of the computer Connect the other end of the cable to the keyboard port of the REMOTE module This is the only connection required 3 On the REMOTE module change switch 1 to the ON position 4 Attach the power supply unit to the POWER input of the REMOTE module and connect the mains lead to a nearby wall socket 5 Switch on the computer The upgrade process will start automatically and c...

Страница 20: ...ing the factory default sharpness settings Please refer to the Image controls sharpness and brightness section in the Special Configuration chapter Temporarily disconnect the video link to the LOCAL module connect a monitor directly to the computer video port and check for a correct video image output The keyboard indicators are flashing between the Caps Lock and the Num Lock Scroll Lock and the c...

Страница 21: ...elecommunications equipment Warning the power adapter contains live parts No user serviceable parts are contained within the power adapter do not dismantle Plug the power adapter into a socket outlet close to the AdderLink unit that it is powering Replace the power adapter with a manufacturer approved type only Do not use the power adapter if the power adapter case becomes damaged cracked or broke...

Страница 22: ... the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an experienced radio TV technician for help FCC Compliance Statement United States This equipment generates uses and can radiate radio frequency energy and if not installed and used properly that is in strict accordance with the manufact...

Страница 23: ...o ADD0056 Adder Technology Limited Technology House Trafalgar Way Bar Hill Cambridge CB3 8SQ United Kingdom Tel 44 0 1954 780044 Fax 44 0 1954 780081 Adder Corporation 29 Water Street Newburyport MA 01950 United States of America Tel 1 888 932 3337 Fax 1 888 275 1117 www ctxd com Documentation by ...

Отзывы: