DC

Power in

A power adapter is supplied with a country-

specific power cord. The power adapter uses 

a locking-type plug to help prevent accidental 
disconnection; please follow the instructions 
shown on the right when disconnecting a 
power adapter. 

Note: When first powered on and booting up, the 

indicators and screen of the ALIF3000 unit will 

not respond for roughly 40 seconds. 

  

To connect the power adapter

1  Attach the output plug of the supplied 

power adapter to the power input socket 
on the left side of the rear panel.  As you 
insert the plug, pull back slightly on the 
outer body to assist the locking mechanism 
until the plug is fully inserted.

Insert the IEC connector of the supplied country-specific power cord to the socket of 

the power adapter.

3  Connect the power cord to a nearby mains supply socket.

To disconnect the power adapter

1  Isolate the power adapter from the mains supply.
2  Grasp the outer body of the power adapter plug 

where it connects with the node.

3  Gently pull the body of the outer plug away from 

the node.  As the body of the plug slides back, it will 
release from the socket and you can fully withdraw 
the whole plug. 

IMPORTANT: Please read and adhere to the electrical safety information 

given within the Safety information booklet provided with this product. In 

particular, do not use an unearthed power socket or extension cable.

Note: The unit and the power adapter generate heat when in operation and will become 

warm to the touch. Do not enclose them or place them in locations where air cannot circulate 

to cool the equipment. Do not operate the equipment in ambient temperatures exceeding 

40 degrees Centigrade. Do not place the products in contact with equipment whose surface 

temperature exceeds 40 degrees Centigrade. 

From the  

power adapter

Gently pull back the plug outer 

body to release the lock 

KVM & VM

NETWORK

VM-ONLY

NETWORK

ALIF3000 RX

VIDEO

DISPLAYS

AUDIO

S

DEVICE

POWER

IN

USB

DEVICES

Содержание ADDERLink INFINITY 3000

Страница 1: ...ADDERLink INFINITY 3000 User Guide Experts in Connectivity Solutions KVM Extension Solutions...

Страница 2: ...work link 12 Configuration ALIF3000 configuration 13 The recessed power button 13 Performing a manual factory reset 13 Creating an RDP session 14 Operation OLED screen 16 Front panel indications 17 Fu...

Страница 3: ...outside of control by AIM Dual DisplayPort video outlets provide support for a single 2560x1600 display or two at a maximum 1920x1200 resolution 60Hz refresh Gigabit connections The ALIF3000 receiver...

Страница 4: ...uction Connectors Desk 2x DisplayPort 6x USB type A 3x 3 5mm audio jack sockets Ethernet 1x 8p8c RJ45 2x SFP cages Power 3 pin Kycon socket USB 6 ports of USB2 0 with USB True Emulation to support key...

Страница 5: ...ontrol button to scroll through the various informational pages and also a status indicator Rear Front AdderLink 3 0 0 0 1 2 Micro phone Headphones USB Reset switch OLED screen Control button and stat...

Страница 6: ...DEX AdderLink 3 0 0 0 1 2 SUPPLIED ITEMS ALIF3000 package Information wallet containing Four self adhesive rubber feet Quick start guide Safety document ALIF3000 RX unit Power adapter with locking con...

Страница 7: ...FP module Part number SFP MM LC Please refer to the table in Appendix F for information about fiber modules and cables Replacement power adapter with locking connector Part number PSU IEC 12VDC 5A Cou...

Страница 8: ...IMPORTANT When using an ADDERLink INFINITY Management AIM server to configure ALIF units it is vital that all ALIF units that you wish to locate and control are set to their factory default settings...

Страница 9: ...ary video display To primary video display Audio The ALIF3000 unit can support a microphone as well as speakers and or headphones To connect a microphone headphones and or speakers 1 Connect the lead...

Страница 10: ...that may be drawn from the USB ports is 1 2A which should be sufficient for a keyboard mouse no more than 100mA each and any two other devices 500mA maximum each If more power for USB devices is requ...

Страница 11: ...the power adapter 1 Isolate the power adapter from the mains supply 2 Grasp the outer body of the power adapter plug where it connects with the node 3 Gently pull the body of the outer plug away from...

Страница 12: ...ated on the rear panel of the unit KVM VM network links Two SFP ports are located on the rear panel to allow fiber or copper links to separate networks according to the type of modules that are insert...

Страница 13: ...port is not supported by AIM and the ALIF3000 is not discoverable by AIM through this port It is used to accessVM machines on a separate network to the KVM network KVM VM NETWORK VM ONLY NETWORK ALIF...

Страница 14: ...t panel OLED screen for 10 seconds until the indicator turns blue and the OLED screen shows the message In factory reset mode 3 You can now either Return to normal operation without resetting Press th...

Страница 15: ...server to issue the CATx interface its IP address subnet mask gateway and DNS settings ALIF3000 AIM ALIF TX ALIF TX Infinity network Corporate network Virtual machines To create an RDP session 1 With...

Страница 16: ...to enter the user credentials You should now see the new RDP channel displayed on the OSD or amongst the pages of other channels and presets An RDP channel only has two icons unlike the other channels...

Страница 17: ...mary page will indicate the AIM connection status Searching Connecting or Connected Connection page Shows the name of the current channel and also the console peripherals that are connected and operat...

Страница 18: ...r color and flash patterns The single front panel indicator uses varying color and flashing patterns to signal key status Off No power Green All services present as compared to the configuration requi...

Страница 19: ...his guide then please refer to the Support section of our website www adder com Further information LITHIUM BATTERY CAUTION This product contains a lithium battery which must be disposed of in the cor...

Страница 20: ...configuration page should be displayed IP Address 2 10 0 20 37 Identify unit When clicked these buttons cause the front panel indicators to flash to assist with identifying the ALIF unit within a rac...

Страница 21: ...e number of ALIF transmitters that will be used to create multicast groups Check the throughput of the switch Full duplex 1Gbps up and down stream speeds per port Use the same switch make and model th...

Страница 22: ...048 x 2048 ensure that Jumbo Frames are enabled on all switches Choose an appropriate forwarding mode on all switches Use Cut through if available otherwise Store and forward Optimize the settings on...

Страница 23: ...are output by an ALIF unit but the network switches have not been configured to use jumbo frames the switches will attempt to break the large packets down into standard packets This process introduces...

Страница 24: ...P enabled but do not also have portfast enabled on the ports to which ALIF units are connected Without portfast enabled ALIF units will all be assigned the same zero config IP address at reboot and AI...

Страница 25: ...l hosts report which multicast streams they wish to receive The Querier device and all snooping Layer 2 switches then update their lists accordingly the lists are also updated when Join Group and Leav...

Страница 26: ...ans that cut through switches cannot discard faulty packets themselves However on receipt of the marked packet a host will carry out the discard process Fragment free is a hybrid of the above two meth...

Страница 27: ...that is assigned to every networking device at manufacture Deciphering recipients at this level is more straightforward than at Layer 3 where the address of the recipient is represented by a logical I...

Страница 28: ...e Coding Distance at 1Gbps Adder part number for SFP module Normal applications Suggested print nomenclature OM1 62 5 125 Multimode TIA 492AAAA Orange 62 5 125 220m SFP MM LC OM2 50 125 Multimode TIA...

Страница 29: ...vider A 5 Gently tighten the thumbscrew so that the spacer engages with the inner edges of the two ALIF3000 units and holds them in place B 6 Place the power adapters in the rear section of the rack m...

Страница 30: ...included in this product contains copyrighted software that is licensed under the GNU General Public License GPL You may obtain the complete Corresponding Source Code from Adder for a period of three...

Страница 31: ...STALLATION CONFIGURATION OPERATION FURTHER INFORMATION INDEX www ctxd com Documentation by 2020 Adder Technology Limited All trademarks are acknowledged Part No MAN ALIF3000 ADDER Release 1 2 www adde...

Страница 32: ...umbo frames packets 24 L Layers 2 and 3 25 Lithium battery 18 M MAC Address 16 Mounting 7 N Network layout 20 Network links 11 KVM VM 11 VM only 12 Network switch choosing 20 O OLED screen 16 OSI mode...

Отзывы: