Hot plugging PS/2-style connections and mouse restoration

For computer systems that use PS/2-style keyboard and mouse connections, 
it is strongly recommended that you switch off the computer system before 
attempting to connect it via the CAM. However, if this is not possible then you 
need to ‘hot plug’ the CAM while power is still applied to the system (keyboards 
and mice with USB connections are unaffected by hot-plugging). There is 
not normally a danger of damage to the system, however, when PS/2 mouse 
communications are interrupted, often they fail to reinitialise when reconnected. 
CAMs provide a feature to reinstate mouse communications once the necessary 
connections have been made.
There are two main types of data formats used by current PC mice, these are the 
older ‘PS/2’ format and the more recent ‘IntelliMouse

®

’ format introduced by 

Microsoft. These use slightly different data arrangements and it is important to 
know which type was being used before you hot-plugged the CAM module. The 
previous setting depends both on the type of mouse and the type of driver as 
various combinations of PS/2 and Intellimouse are possible. Using the incorrect 
restore function may produce unpredictable results and require the system to be 
rebooted.

Which restore setting do I use?

The general rule is that unless both the mouse 

and

 the driver are 

both

 

Intellimouse compatible then you need to restore the mouse as ‘PS/2’. 

Recognising an Intellimouse-style mouse

The Intellimouse format was introduced to support, among other features, the 
scroll wheel function. If your mouse has a scroll wheel, then it is likely to support 
the Intellimouse format. If you have a Microsoft mouse, then it will usually state 
that it is an Intellimouse on its underside label. 

Recognising an Intellimouse driver

Before hot plugging your CAM (or afterwards using only keyboard control), 
access the Windows Control Panel and select either the 

Mouse

 option (on 

Windows NT, 2000 and XP) or the 

System

 option (on Windows 95, 98, ME). 

Look for the name of the driver, which will usually include the words 

PS/2

 or 

Intellimouse

To restore mouse operation when hot plugging:

1  Carefully connect the CAM to the system and its keyboard, mouse, monitor 

and audio output (if used).

2  Simultaneously, press the hotkeys (by default, 

 and 

) along with 

 

to enter configuration mode.

3  Enter the appropriate restore function code:   

• 

PS/2

 – press        

• 

IntelliMouse

 – press          

4  To exit configuration mode, press 

.

5  Move the mouse a short distance and check for appropriate on-screen 

cursor movement. If the mouse cursor darts erratically around the screen, 
then cease moving the mouse. This is an indication that the chosen restore 
function is incorrect. Try again using the other restore function.

Note: The restore functions predict the likely mouse resolution settings but 
may not restore the exact speed or sensitivity settings that were originally 
set. 

Microsoft and Logitech -specific mouse settings

In certain installations some Logitech mouse drivers may lose the action of the 
mouse buttons when used with the standard ‘Microsoft compatible’ signalling 
protocol used between the modules. To solve this problem, select the ‘Logitech 
compatible’ mouse signalling protocol.

To change mouse signalling protocols

1  Simultaneously, press the hotkeys (by default, 

 and 

) along with 

 

to enter configuration mode.

2  Enter the appropriate protocol code:   

• 

Microsoft compatible

 – press        

• 

Logitech compatible

 – press          

3  To exit configuration mode, press 

Содержание Adder X00 Extender

Страница 1: ...REMOTE ADDER PW R TO LOCAL 1 TO LOCAL 2 Adder X200 Extender User Guide...

Страница 2: ...tem 8 Special configuration Configuration 9 What are hotkeys 9 Entering using and exiting configuration mode 9 Password setting 10 Mouse switching control 10 Hot plugging PS 2 style connections and mo...

Страница 3: ...ory 5 5e or 6 twisted pair cabling Special circuitry within the remote module allows you to make adjustments to the sharpness and brightness settings to suit your own preferences PSU X200 CAM CAM PC1...

Страница 4: ...able with or without audio and skew compensation capabilities Serial flash upgrade cable 4 way jack connector to 9 way D type male serial connector not pictured Part number CAB 9DF RJ9 2M What you may...

Страница 5: ...networks While these uneven twists work well for Ethernet signals they can impose problems for the video signals transceived by the X200 modules The X200 modules send the red green and blue video sign...

Страница 6: ...to the socket of the CAM The other end of each cable run will attach to the remote X200 module Computer Access Module Category 5 5e or 6 cable to X200 module Green indicator power present Yellow indi...

Страница 7: ...lled POWER 5 Insert the IEC connector of the supplied power lead into the corresponding socket of the power supply Connect the other end of the power lead to a nearby mains socket 6 Where necessary us...

Страница 8: ...1 OFF Normal operation ON Before power is applied Places the X200 module into flash upgrade mode so that the internal software can be changed Please see the Flash upgrade section in the Special config...

Страница 9: ...ators adjacent to the CATx connectors on the X200 module will be lit To unlock the system 1 Enter the correct password and press Note Passwords are NOT case sensitive Note If an invalid password has b...

Страница 10: ...s are also needed for computer tasks you can change them for another combination using switches 2 and 3 on the X200 remote module 2 OFF 3 OFF Hotkeys and default setting 2 OFF 3 ON Hotkeys and 2 ON 3...

Страница 11: ...tings 1 Connect the X200 module to a computer in the same manner as you would to carry out a flash upgrade see Performing flash upgrades 2 While power is applied set the X200 upgrade switch SW1 to its...

Страница 12: ...t is likely to support the Intellimouse format If you have a Microsoft mouse then it will usually state that it is an Intellimouse on its underside label Recognising an Intellimouse driver Before hot...

Страница 13: ...rd indicators Num Lock Caps Lock and Scroll Lock will now begin to flash in sequence The speed of the sequence indicates the level of the sharpness adjustment currently applied the slower the rate the...

Страница 14: ...8 6 5 2 Data signal Red video signal Green video signal Blue video signal 7 3 4 1 7 3 4 1 To use skew adjustment 1 Display a skew pattern on the appropriate computer You can either use the supplied s...

Страница 15: ...el Corresponding keyboard indicators will flash rapidly to show which channel is currently selected for adjustment Num Lock for Red Caps Lock for Green and Scroll Lock for Blue Advance colour timing R...

Страница 16: ...nto its ON position 3 Use the optional upgrade cable to link between the socket adjacent to the X200 switch block and a vacant RS232 9 way serial port of the computer system to be used R E M O T E A D...

Страница 17: ...ick the Upload Now button The progress will be shown within the dialog Should you decide not to continue with the upload at any stage click the Abort button response to this is usually immediate howev...

Страница 18: ...information Getting assistance Adder Technology website www adder com Check the Support section of our website for the latest solutions and driver files Email support adder com Fax in the UK 01954 780...

Страница 19: ...d in compliance with all applicable wiring regulations Do not connect CATx link interfaces RJ45 style connectors to any other equipment particularly network or telecommunications equipment Warning the...

Страница 20: ...b Increase the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an e...

Страница 21: ...imited Technology House Trafalgar Way Bar Hill Cambridge CB3 8SQ United Kingdom Tel 44 0 1954 780044 Fax 44 0 1954 780081 Adder Corporation 29 Water Street Newburyport MA 01950 United States of Americ...

Отзывы: