Adcom GFA-7700 Скачать руководство пользователя страница 7

Front Panel

On/Off Switch (6)

The On/Off Switch controls power to the power transformer and circuits of the GFA-7700. Whenever 

the GFA-7700 is energized the Power LED (7) will glow. To turn the GFA-7700 on, press the push-button. 

It will remain in the “engaged” position while the unit is energized. To turn the GFA-7700 off, press the 

push-button in and release and it will move to the “disengaged” position.

Power LED (7)

This LED will glow whenever the On/Off Switch (6) is turned on and the GFA-7700 is energized. The 

Power LED indicates that there is AC voltage being fed to the amplifier, but it does not signify that all 

the amplifier’s circuits are in operation. If, for example, one of the Thermal Protection LED (9) glows, 

that amplifier channel will not produce sound even though the Power LED may still glow. When the 

GFA-7700 is turned off, the Power LED will take some time to fade out completely. It may take up to 30 

seconds to fully extinguish.

Additionally, the internal power transformer is provided with a thermostat which will interrupt power 

into the transformer if its temperature exceeds 125°C. This high temperature will seldom, if ever, be 

encountered unless the amplifier is subjected to abnormal conditions, such as operation into loads of 

less than 3 ohms at very high listening levels, etc. If the AC Fuse (4) has not failed, the Power LED is 

out, and the Thermal Protection LED (9) does not glow, this would indicate that the thermostat within 

the transformer has opened.

Once the temperature within the transformer decreases to a normal level, the thermostat will reset 

itself automatically and normal operation will resume. If you are to avoid continually tripping the 

thermostat in the transformer, you must reduce the sound level demands, correct the load impedance 

of the loudspeakers, or both.

7

(6)

(7)

(9)

(8)

Содержание GFA-7700

Страница 1: ...GFA 7700 High Current 5 Channel Power Amplifier Owner s Manual...

Страница 2: ......

Страница 3: ...ut devices Convenient 12 VDC power ON OFF triggering Heavy gauge anodized aluminum front panel Powder coated baked chassis and top cover for greater durability Cooling vents for greater efficiency and...

Страница 4: ...onnections to it ADCOM Protection Plan USA ONLY ADCOM offers the enclosed valuable Limited Warranty Please read the details on the Warranty Card carefully to understand the extent of the protection of...

Страница 5: ...kers are made through high grade 5 way gold plated binding post terminals There are two terminals for each speaker which are colored RED for the positive output and BLACK for the negative output The b...

Страница 6: ...Fuse only with one identical in type and rating as printed on the rear panel DO NOT USE ANY SUBSTITUTE FUSES WITH DIFFERENT RATINGS OR VALUES Failure to observe this precaution may cause serious dama...

Страница 7: ...hen the GFA 7700 is turned off the Power LED will take some time to fade out completely It may take up to 30 seconds to fully extinguish Additionally the internal power transformer is provided with a...

Страница 8: ...has been triggered and the amplifier is inoperative The thermal protection circuitry will typically be triggered by very high power demands into impedances much lower than the amplifier is capable of...

Страница 9: ...nal components It is imperative that these vents are not obstructed in any way We recommend that you do not stack other components on top of the GFA 7700 Not only will heat generated by the amplifier...

Страница 10: ...designations are as you are sitting down in your listening viewing area On the rear panel the inputs and outputs are grouped in 5 bracketed sets one for each channel They are as follows RS Right Surr...

Страница 11: ...rity positive to positive negative to negative On the GFA 7700 the positive terminal is color coded RED and labeled and the negative is color coded BLACK and labeled The positive terminal on the speak...

Страница 12: ...y high volumes levels from your system It is not recommended that you run additional sets of speakers on any or all of the amplifiers in the GFA 7700 in order to insure the integrity of the system If...

Страница 13: ...solator works only partially or not at all then please read Note 2 to complete the troubleshooting procedure Note 2 Make sure that the power amplifier is at least six inches from the Preamp and or Pro...

Страница 14: ...HOULD YOUR UNIT BE SHIPPED TO OUR FACTORY WITHOUT PRIOR AUTHORIZATION OR PACKED IN OTHER THAN ITS ORIGINAL CARTON AND FILLERS For fax inquires please include a return fax or voice number for the reply...

Страница 15: ...ohms 0 01 Dynamic Headroom 1 9 dB Signal to Noise Ratio A Weighted 115dB Gain 29dB Input Sensitivity for 1 Watt 0 1 volts for 150 Watts 1 14 volts Input Impedance 50k Damping Factor 20Hz to 20kHz 800...

Страница 16: ...8551 East Anderson Drive Suite 105 Scottsdale Arizona 85255 Voice 480 607 2277 Fax 480 348 9876 www adcom com gfa7700_manual_v1...

Отзывы: