1-2 

12706A Text Fixture Operation Manual

 

1.2    Before Using the Product 

1.2  Before Using the Product 

1.2.1 Appearance 

Check 

When receiving the 12706A, inspect it for any damage during transportation. 

If there is any damage in appearance, please contact ADC Corporation or your sales represent-

ative. 

Our address and phone number are listed at the end of this manual. 

 

1.2.2 Operating 

Environment 

(1)

 

Use the 12706A in an area free from dust, corrosive gas and vibrations and away from di-

rect sunlight.   

(2)

 

The ambient temperature should be -20°C to + 80°C, the relative humidity should be 80% 

or less. 

(3)

 

Storage 

The storage temperature range is from -25°C to +80°C. 

When not in use for a long time, cover the 12706A with a plastic sheet or put in a card-

board box, and store it in a low humidity area away from direct sunlight. 

(4)

 

Transportation 

When transporting the 12706A, pack with the packaging materials used at delivery. If the 

packaging materials have been lost, pack the 12706A by using the following procedure: 

a)

 

Wrap the 12706A with a plastic sheet. 

b)

 

Put it in a cardboard box (with thickness of 5 mm or more) and protect it with cu-

shioning materials. 

c)

 

Fix the outside with packing tape. 

 

 

Содержание 12706A

Страница 1: ...2009 ADC CORPORATION First printing March 31 2009 All rights reserved Printed in Japan 12706A Test Fixture OPERATION MANUAL Manual Number FOE 00000048A00...

Страница 2: ......

Страница 3: ...2 Part Descriptions 2 1 3 Methods of Use 3 1 3 1 Attaching a Sample 3 1 3 2 Connecting to the Measuring Instruments 3 2 3 2 1 Preparation before Connection 3 2 3 2 2 Connecting with the 8340A 3 3 3 2...

Страница 4: ......

Страница 5: ...eration Manual List of Illustrations No Title Page 2 1 12706A Part Descriptions 2 2 3 1 Attaching a Sample 3 1 3 2 Connecting with the 8340A 3 3 3 3 Connecting with the 8240 and the 6161 3 4 3 4 Repla...

Страница 6: ......

Страница 7: ...06A Test Fixture Operation Manual List of Tables No Title Page 1 1 Parts with Limited Service Life 1 3 3 1 Connectable Measuring Instruments and Necessary Cables Accessories 3 2 3 2 Test Socket Standa...

Страница 8: ......

Страница 9: ...ulation resistance measurement and VSIM voltage source current measurement of capacitors and other electrical components Features 1 A shielded and insulated structure is adopted allowing stable measur...

Страница 10: ...unlight 2 The ambient temperature should be 20 C to 80 C the relative humidity should be 80 or less 3 Storage The storage temperature range is from 25 C to 80 C When not in use for a long time cover t...

Страница 11: ...ct ADC Corporation or your sales representative For how to replace the test socket refer to Chapter 3 5 Test Socket Replacement Table 1 1 Parts with Limited Service Life Part name Durability times ADC...

Страница 12: ......

Страница 13: ...CE HI LO t nects to the V nects to the c s Figure 2 1 measuremen ASURE of the he input termi terminal for v V SOURCE o chassis 12706A Pa t e test socket inal of a mea voltage appli of the test soc 127...

Страница 14: ...LID SIGNAL 3 6 Applied voltage switch switch that shuts off the voltage applied to the V SOURCE ter minal of the test socket when the cover is opened The applied voltage switch has mechanical durabili...

Страница 15: ...le as sh e e procedure o e V SOURC asurement B to be measur or less diam 1 14 mm or hown below Figur of attaching a CE terminal f Be careful wh red meets the meter 14 mm less re 3 1 Atta CAUTION 12706...

Страница 16: ...Connection The following table shows connectable instruments and necessary cables Table 3 1 Connectable Measuring Instruments and Necessary Cables Accessories Model Terminal Measuring instrument Volta...

Страница 17: ...TRIAX cable A01009 or A01239 3 Connect the V SOURCE HI of the 8340A to the V SOURCE HI of the 12706A by using the banana banana cable A01240 The V SOURCE LO does not need connecting 4 Connect the LID...

Страница 18: ...3 4 12706A 3 2 Co A Text Fixtu onnecting to t ure Operatio the Measurin F on Manual ng Instrumen Figure 3 2 nts Connecting with the 834 40A...

Страница 19: ...TRIAX cable A01009 2 Connect a voltage source such as the 6161 or 6144 to the V SOURCE binding post of the 12706A by using the banana banana cable A01240 1 The output voltage of the voltage source mus...

Страница 20: ...3 6 12706A 3 2 Co A Text Fixtu onnecting to t ure Operatio the Measurin Figure 3 on Manual ng Instrumen 3 3 Connec nts cting with th he 8240 and t the 6161...

Страница 21: ...2 to the INPUT of the 12706A by using the TRIAX TRIAX cable A01009 2 Connect the HI and LO of the 8252 short circuit between LO and GND to the V SOURCE of the 12706A by using the output cable A01044 a...

Страница 22: ...t VSIM or voltage source resistance measurement VSRM For the 8240 set to DC current measurement 4 Closing the cover of the 12706A will turn on the applied voltage switch allowing mea surement 1 12706A...

Страница 23: ...p es as persona eak current i program list program exa al computer is measured a ample for m in Figure 3 as i t charact 12706A T easurement 2 Voltage i teristic Test Fixture 3 by GPIB co is applied t...

Страница 24: ...nterface clear remote enabled Initialize the 8340A Initialize the 8340A parameters Set the 8340A parameters MO1 Sampling HOLD PVS25 Source voltage 25 V Set the 8340A to discharge status Make discharge...

Страница 25: ...3 3 Sample p program resu ult 12706A T Test Fixture 3 Operation M 3 4 Sample 3 11 Manual Program...

Страница 26: ...socket in accordance with the following procedure Table 3 2 Test Socket Standard Part name Stock No Standard name Test socket JCE AB004EX01 1 201 0080 000605 Textool 3M Note Quote the stock number of...

Страница 27: ...bl Panel nel Flat he Replacing th S le Test s ead screw M2 12706A T he Test Socke oldering iron socket Nut Spring wa Test socke 2 x 12 Test Fixture 3 5 Repl et n asher et Operation M lacing the Te 3 1...

Страница 28: ......

Страница 29: ...INPUT signal line V SOURCE HI 1 1015 or higher INPUT signal line Chassis 1 1015 or higher V SOURCE HI Chassis 1 109 or higher Connector INPUT triaxial connector V SOURCE HI biding post red V SOURCE L...

Страница 30: ......

Страница 31: ...A1 1 Internal l Connect tion 12706A T Test Fixture Operation M A A1 1 Manual Appendix...

Страница 32: ...A1 2 12706A Appendix A1 2 A Text Fixtu x 12706A E ure Operatio External on Manual View...

Отзывы: