Page 7

Connect the grounding wire to the grounding system. Leave sufficient slack in the grounding
wire to allow it to be routed into the cabinet after the cabinet is mounted on the pad.

Содержание OmniReach FDH 3000

Страница 1: ...EM INSTALLATION 6 6 CUSTOMER INFORMATION AND ASSISTANCE 7 _________________________________________________________________________________________________________ INTRODUCTION This publication descri...

Страница 2: ...and are listed in descending order of severity of injury or damage and likelihood of occurrence PAGE IDENTIFIER DESCRIPTION OF CHANGE Original Danger Danger is used to indicate the presence of a hazar...

Страница 3: ...ation Depending on the landscaping requirements the top surface of the concrete pad may be located from 0 to 3 inches 7 6 cm above the surrounding grade 3 BASE CONSTRUCTION AND CONDUIT INSTALLATION Pr...

Страница 4: ...for the FDH 3000 Small Size Cabinet REINFORCED CONCRETE PAD 6 0 IN 15 2 CM 4 0 IN MIN 10 2 CM GRAVEL OR EQUIVALANT FILL COMPACTED SOIL 21936 A 90 BEND IN DUCT PAD MOUNT FRAME CAST IN PLACE 4 IN DUCT F...

Страница 5: ...to construct the concrete pad 1 Build a wood form for the concrete pad using 2 x 6 framing lumber as shown in Figure 4 2 Locate the PMF using the dimensions provided in the construction diagram see F...

Страница 6: ...electrical codes Check local codes for grounding system installation use of clamps wire size and any other grounding requirements Typically 6 AWG copper wire is used for the ground wire If the ground...

Страница 7: ...123 Issue 1 May 2007 Page 7 Connect the grounding wire to the grounding system Leave sufficient slack in the grounding wire to allow it to be routed into the cabinet after the cabinet is mounted on t...

Страница 8: ...cation may be verified at any time by contacting ADC s Technical Assistance Center ADC Telecommunications S PORE PTE LTD 100 Beach Road 18 01 Shaw Towers Singapore 189702 ADC Telecommunications INC PO...

Отзывы: