background image

6

American Dryer Corp.

113362 - 25

MAXIMUM CAPACITY (DRY WEIGHT)

95 lb

43.09 kg

TUMBLER DIAMETER

41-3/8”

105.11 cm

TUMBLER DEPTH

28-7/8”

73.34 cm

TUMBLER VOLUME

22.50 cu ft

637.129 L

TUMBLER/DRIVE MOTOR

1/2 hp

0.37 kW

BLOWER/FAN MOTOR

3  hp

2.24 kW

DOOR OPENING (DIAMETER)

31-3/8”

79.71 cm

DOOR SILL HEIGHT

24-1/2”

62.23 cm

WATER CONNECTION

3/4”-11.5  NH 

(North Ameri ca)

3/4” B.S .P.T. 

(Outsi de North Ameri ca)

DRYERS PER 20’/40’ CONTAINER

10 / 20

DRYERS PER 48’/53’ TRUCK

24 / 26

VOLTAGE AVAILABLE

208-460v    3ø    3,4w    50/60 Hz

APPROX. NET WEIGHT

1,087  lb

493.05 kg

APPROX. SHIPPING WEIGHT

1,157  lb

524.81 kg

AIRFLOW

60 Hz

2,700 cfm

76.46 cmm

50 Hz

2,250 cfm

63.71 cmm

HEAT INPUT

350,000  Btu/hr

88,199 kcal/hr

EXHAUST CONNECTION (DIAMETER)

16”

40.64 cm

COMPRESSED AIR CONNECTION

1/4” Qui ck C onnecti on

COMPRESSED AIR VOLUME

4.25 cfh

0.12 cmh

INLET PIPE CONNECTION

1” F.N.P.T.

1” F.B.S .P.T. 

(C E and Australi a Only)

VOLTAGE AVAILABLE

N / A

APPROX. NET WEIGHT

APPROX. SHIPPING WEIGHT

AIRFLOW

EXHAUST CONNECTION (DIAMETER)

COMPRESSED AIR CONNECTION

COMPRESSED AIR VOLUME

OVEN SIZE

kW

Btu/hr

kcal/hr

VOLTAGE AVAILABLE

N / A

APPROX. NET WEIGHT

APPROX. SHIPPING WEIGHT

AIRFLOW

STEAM CONSUMPTION

OPERATING STEAM PRESSURE

EXHAUST CONNECTION (DIAMETER)

COMPRESSED AIR CONNECTION

COMPRESSED AIR VOLUME

BOILER HP (NORMAL LOAD)

SUPPLY CONNECTION

RETURN CONNECTION

Specifications _______________________________________________________________________

Shaded areas are stated in metric equivalents

9/27/04

GAS

ELECTRIC

STEAM

NOTE: 

The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

Содержание ML-96

Страница 1: ... des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT ...

Страница 2: ...your order is processed accurately and promptly These instructions are only valid if the following country code is on the appliance If this code is not present on the appliance it is necessary to refer to the technical instructions which will provide the necessary information concerning the modification of the appliance to the condition of use for the country In accordance with EN ISO 3166 1 the n...

Страница 3: ...Do not dry mop heads in the dryer Do not use dryer in the presence of dry cleaning fumes The dryers must not be installed or stored in an area where it will be exposed to water and or weather The wiring diagram for the dryer is located in the front electrical control box area List of Acronyms _____________________________ D M S Drill Measurement Size DSI Direct Spark Ignition HVAC Heating Ventilat...

Страница 4: ...oid the warranty Under no circumstances should the dryer door switch es lint door drawer switch es or heat safety circuit s ever be disabled This dryer is not to be used in the presence of dry cleaning solvents or fumes Remove articles from the dryer as soon as the drying cycle has been completed WARNING Articles left in the dryer after the drying and cooling cycles have been completed can create ...

Страница 5: ..._______________________________________________________ ____________________________________________________________ NOTES _____________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ________________________________________...

Страница 6: ... CONNECTION DIAMETER 16 40 64 cm COMPRESSED AIR CONNECTION 1 4 Quick Connection COMPRESSED AIR VOLUME 4 25 cfh 0 12 cmh INLET PIPE CONNECTION 1 F N P T 1 F B S P T CE and Australia Only VOLTAGE AVAILABLE N A APPROX NET WEIGHT APPROX SHIPPING WEIGHT AIRFLOW EXHAUST CONNECTION DIAMETER COMPRESSED AIR CONNECTION COMPRESSED AIR VOLUME OVEN SIZE kW Btu hr kcal hr VOLTAGE AVAILABLE N A APPROX NET WEIGHT...

Страница 7: ...dclaundry com 7 Specifications _____________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation ...

Страница 8: ...ryer must be installed with a proper exhaust duct connection to the outside as noted in this manual refer to Exhaust Requirements section The dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual refer to Exhaust Requirements section IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be i...

Страница 9: ...dryer base To reinstall the top console module reverse the above steps NOTE After reinstalling top console module assure electric phase sequence is correct and motors are turning in the proper direction refer to Preoperational Test section A 40 inches 101 6 cm for optimum opening of load door B The maximum thickness of the bulkhead is 4 inches 10 16 cm For electric dryers the maximum thickness of ...

Страница 10: ...e duct all the way around The duct must be centered within this opening As per the National Fuel Gas Code Exhaust ducts for type 2 clothes dryers shall be constructed of sheet metal or other noncombustible material Such ducts shall be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 26 gauge 0 0195 inches 0 50 mm thick Fresh Air Supply Requireme...

Страница 11: ...lbows used for outside protection from the weather no more than 1 elbow should be used in the exhaust duct run If more than 1 elbow is used the cross sectional area of the ductwork must be increased Outside Ductwork Protection To protect the outside end of the horizontal ductwork from the weather a 90 elbow bent downward should be installed where the exhaust exits the building If the ductwork trav...

Страница 12: ...nd conforms to local and state regulations or codes In the absence of such codes all electrical connections materials and workmanship must conform to the applicable requirements of the National Electrical Code ANSI NFPA NO 70 LATEST EDITION or in Canada the Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION For personal safety the dryer when installed must be electrically grounde...

Страница 13: ...ssible it is suggested that a separate ground wire size per local codes be connected from the ground connection of the dryer to a grounded cold water pipe Do not ground to a gas pipe or hot water pipe The grounded cold water pipe must have metal to metal connection all the way to the electrical ground If there are any nonmetallic interruptions such as a meter pump plastic rubber or other insulatin...

Страница 14: ... gas dryer is not provided with an internal gas supply shutoff and an external gas supply shutoff must be provided Technical Gas Data Gas Specifications For Australia refer to data plate back panel Shaded areas are stated in metric equivalents Measured at outlet side of gas valve pressure tap when gas valve is on Shaded area is stated in metric equivalent D M S equivalents are as follows Natural G...

Страница 15: ... rear of the dryer A flexible supply line coupling must be used in an effort to avoid damaging the electric water solenoid valve NOTE The 3 4 11 5 NH is a standard hose coupling screw thread It is not to be confused with 3 4 N P T The sealing of an NH connection is made with a washer opposed to the mating threads of an N P T assembly The 2 thread designs are not compatible It is recommended that a...

Страница 16: ...e water connection for the manual bypass is made to the T or three way fitting which has a 3 8 F P T and a coupling must be used to provide the minimum 1 2 inch 12 7 mm supply feed line If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold freezing temperatures provisions must be made to protect these water lines from freezing Electrical Requireme...

Страница 17: ...sed parameter program selections If computer program changes are required refer to the computer programming manual which was shipped with the dryer Tumbler Coating The tumbler is treated with a protective coating We suggest dampening old garments or cloth material with a solution of water and nonflammable mild detergent and tumbling them in the tumbler to remove this coating WARNING ELECTRICAL SHO...

Страница 18: ... valve burner area 3 Phase 3ø Electric Service Check the electric service phase sequence 3 phase 3ø models only While the dryer is operating check to see if the blower fan is rotating in the proper direction Looking from the front the blower fan should spin in the clockwise direction if it is the phasing is correct If the phasing is incorrect reverse 2 of the 3 leads at connections L1 L2 and L3 of...

Страница 19: ...s or refunds will be issued and the merchandise will be discarded Service Parts Information __________ Service Service must be performed by a qualified trained technician service agency or gas supplier If service is required contact the reseller from whom the equipment was purchased If the reseller cannot be contacted or is unknown contact the Service Department for a reseller in your area NOTE Wh...

Страница 20: ...lation in and around the motor s casing opening NOTE To prevent damage avoid cleaning and or touching ignitor flame probe assembly Every 6 Months Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryer s internal exhaust ducting NOTE The accumulation of lint in the exhaust ductwork can create a potential fire hazard Do not obstruct the flow of combustion a...

Страница 21: ...n Coin Models Upon completing installation of the replacement microprocessor controller computer board reestablish power to the dryer Start the drying cycle by pressing any of the preset cycles in letters A F Verify that the applicable indicator lights on the microprocessor controller computer board are lit Refer to the illustration below Theory of Operation Start the drying cycle When the gas bur...

Страница 22: ... Allows the manufacturer to gather information on your particular dryer 3 Type of Heat This describes the type of heat for your particular dryer gas either natural gas or propane gas electric or steam 4 Heat Input For Gas Dryers This describes the heat input in British thermal units per hour Btu hr or kilowatts kW 5 Orifice Size For Gas Dryers Gives the number drill size used 6 Electric Service Th...

Страница 23: ...ront right side of the burner box WARNING Discontinue power to dryer before attempting to reset hi limit NOTES _____________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________...

Страница 24: ...ADC Part No 113362 25 09 17 21 ...

Отзывы: