J.  PREOPERATIONAL TESTS

ALL

 dryers are thoroughly tested and inspected before leaving the factory.  However, a preoperational test

should be

 performed before the dryer is publicly used.  It is possible that adjustments have changed in transit or

due to marginal location (installation) conditions.

1. Turn on electric power to the dryer.

a. Open 

ALL

 shut-off valves (Gas Models Only)

2. Refer to the Operating Instructions for starting your particular model dryer.

3. Gas Dryers

a. When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition

attempt.  This is because the gas supply piping is filled with air, so it may take a few minutes for the air

to be purged from the lines.

NOTE:

During the purging period, check to be sure that 

ALL

 gas shut-off valves are open.

NOTE:

Gas dryers are equipped with a Direct Spark Ignition (DSI) system which has internal

diagnostics.  If ignition 

is

 

not

 established within three (3) times, the heat circuit in the DSI

module will lockout until it is manually reset.  To reset the DSI system, open and close the main

door and restart the dryer.

b. A gas pressure test 

should be

 taken at the gas valve pressure tap of each dryer to assure that the water

column pressure is correct and consistent.

NOTE:

Water column pressure requirements (measured at the pressure tap of the gas valve body):

Natural Gas ---- 3.5 Inches Water Column (8.7 mb).

L.P. Gas-------- 10.5 Inches Water Column (26.1 mb).

IMPORTANT:

There is no regulator provided in an L.P. (liquid propane) dryer.  The water column

pressure 

must be

 regulated at the source (L.P. tank), or an external regulator 

must be

added to each dryer.

4. Steam Dryers

a. Check to insure that steam damper is functioning properly.

1) The steam damper should not “slam” (open or closed) when it reaches the end of (piston) travel.

Additionally, the steam damper should not bind and/or stop during travel.  If either of these conditions

occur, the flow control 

must be

 adjusted.  Refer to the bottom 

illustration

 on 

page 30

 for air

adjustment instructions.

Содержание ML-82

Страница 1: ...as supplier call the firedepartment Installation and service must be performed by a qualifiedinstaller serviceagencyorthegas supplier AVERTISSEMENT Assurez vousdebien suivrelesinstructionsdonn esdansc...

Страница 2: ...il We have tried to make this manual as complete as possible and hope you will find it useful ADC reserves the right to make changes from time to time without notice or obligation in prices specificat...

Страница 3: ...ENT per OSHA Occupational Safety and Health Administration STANDARDS CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON OR NEAR THE DRYER S WARNING CHILDREN SHOULD BE SUPERVISED IF NEAR DRYER S IN OPERATION CA...

Страница 4: ...d with any of the back guards outer tops or service panels removed PERSONAL INJURY or FIRE COULD RESULT IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and or specified in t...

Страница 5: ...INSTALLATION PROCEDURES 10 A LocationRequirements 10 B Unpacking SettingUp 11 C DryerEnclosureRequirements 12 D FreshAirSupply 13 E ExhaustRequirements 14 F ElectricalInformation 20 G GasInformation 2...

Страница 6: ...VI ROUTINE MAINTENANCE 38 A Cleaning 38 B Adjustments 39 C Lubrication 40 D LintDrawerRemoval 40 SECTION VII PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 41 SECTION VIII DATA LABEL LOCATIO...

Страница 7: ...cepted but the number received and the number refused must be noted on the receipt 4 If you determine that the dryer was damaged after the trucker has left your location you should call the delivering...

Страница 8: ...ppliance b DO NOT touch any electrical switch c DO NOT use any phone in your building d Clear the room building or area of ALL occupants e Immediately call your gas supplier from a neighbor s phone Fo...

Страница 9: ...ational Electrical Code ANSI NFPA NO 70 LATEST EDITION or in Canada the Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION NOTE Failure to do so willVOIDTHEWARRANTY 9 UNDER NO CIRCUM...

Страница 10: ...2 54 cm VOLTAGE AVAILABLE 208 460v 3 50 60Hz APPROX WEIGHT UNCRATED 828 lbs 392 7 kg APPROX WEIGHT CRATED 914 lbs 415 5 kg AIRFLOW 2 500 cfm 98 8 cmm AIR CONNECTION 1 8 F P T STEAM COMSUMPTION BOILER...

Страница 11: ...7 Specifications ML 82 Gas and Steam ONLY NOTE ADC reserves the right to make changes in specifications at any time without notice or obligation...

Страница 12: ...ront View Illus No Description 1 Controls 2 Control top access Door Assembly 3 Main DoorAssembly 4 Lint Compartment Area lint screen located behind door 5 Lint Drawer 6 Data Label and Installation Lab...

Страница 13: ...ic Service Relay Box for Steam Models ONLY 3 Electric Service Relay Box 4 Tumbler Bearing MountAssembly 5 Idler Bearing MountAssembly 6 Basket Drive Motor Assembly for Reversing Models ONLY 7 Blower M...

Страница 14: ...be installed on a sound level floor capable of supporting its weight Carpeting must be removed from the floor area that the dryer is to rest on IMPORTANT The dryer mustbeinstalledonnoncombustiblefloo...

Страница 15: ...st transition piece that must be installed on the outlet of the exhaust before any further venting is connected To do this follow the procedures listed below a Remove the exhaust transition piece from...

Страница 16: ...the top of the dryer A 1 inch 2 54 cm clearance is required NOTE Allowances must be made for opening the control door Dryers may be positioned side wall to side wall However a 1 16 1 5875 mm minimum a...

Страница 17: ...adversely affected Ignition problems and sail switch fluttering problems may result as well as premature motor failure from overheating Air supply make up air must be given careful consideration to a...

Страница 18: ...D The duct work should be laid out in such a way that the duct work travels as directly as possible to the outdoors with as few turns as possible Single or independent dryer venting is recommended Whe...

Страница 19: ...rk diameter for gas models is 14 inches 35 56 cm and 16 inches 40 64 cm for steam models NOTE Where the exhaust duct work passes through a wall ceiling or roof made of combustible materials the openin...

Страница 20: ...T SIZE MUST NOT BE REDUCED ANYWHERE DOWN STREAM OF THE DRYER IMPORTANT Exhaust back pressure measured by a manometer at each basket tumbler exhaust duct area should not exceed 0 3 inches of water colu...

Страница 21: ...n the outside of opening of exhaust duct work 3 Multiple Dryer common Venting If it is not feasible to provide separate exhaust ducts for each dryer ducts from individual dryers may be channeled into...

Страница 22: ...nts must be taped to prevent moisture and lint from escaping into the building Inspection doors should be installed at strategic points in the exhaust duct work for periodic inspection and clean out o...

Страница 23: ...19...

Страница 24: ...49 1 M91 Natural Gas or CAN CGA B149 2 M91 L P Gas or LATEST EDITION IMPORTANT Failure to comply with these codes or ordinances and or the requirements stipulated inthismanualcanresultinpersonalinjury...

Страница 25: ...right to make changes in specifications at any time without notice or obligation MLG 82 Gas MLS 82 Steam ELECTRIC SERVICE SPECIFICATIONS PER DRYER IMPORTANT 208 VAC and 240 VAC ARE NOT THE SAME When o...

Страница 26: ...er distribution block located in the service box at the rear upper left hand corner of the dryer To gain access to the service box and contactor the service box cover must be removed Providing local c...

Страница 27: ...use irreparable damage to the gas valvesVOIDING THE WARRANTY WARNING FIRE orEXPLOSION COULD RESULT 1 Gas Supply The gas dryer installation must meet the American National Standard National Fuel Gas Co...

Страница 28: ...inches water column 26 1 mb There is no regulator or regulation provided in an L P dryer The water column pressure must be regulated at the source L P tank or an external regulator must be added to ea...

Страница 29: ...An in line pressure regulator must be installed in the gas supply line header if the natural gas pressure exceeds 12 inches of water column 29 9 mb pressure IMPORTANT A consistent water column pressur...

Страница 30: ...26...

Страница 31: ...a Inlet 1 1 4 supply line connection qty one 1 at top manifold b Return 1 1 4 return line connection qty one 1 at bottom manifold 2 Installation Instructions To ensure an adequate supply of steam is...

Страница 32: ...rap with a capacity of 1 000 pounds 454 kg of condensate per hour at 125 PSI 8 62 bars is needed for each unit f A 3 4 19 05 mm vacuum breaker should be installed for each unit in the piping This will...

Страница 33: ...hieved 4 Steam Damper System Operation The MLS 82 steam damper as shown in the top illustration on page 30 allows the coil to stay constantly charged eliminating repeated expansion and contraction Whe...

Страница 34: ...justed prior to shipping at 80 PSI 5 51 bars steam damper operation must be checked before the dryer is put into operation Refer to page 32 and page 33 for instructions to check steam damper operation...

Страница 35: ...d at the factory prior to shipping However each sail switch adjustment must be checked to assure that this important safety control is functioning Refer to page 33 for Sail Switch Adjustment 5 GAS MOD...

Страница 36: ...cs If ignition is notestablishedwithinthree 3 times theheatcircuitintheDSI module will lockout until it is manually reset To reset the DSI system open and close the main door and restart the dryer b A...

Страница 37: ...oating We suggest dampening old garments or cloth material with a solution of water and non flammable mild detergent and tumbling them in the basket tumbler to remove this coating 7 Make a complete op...

Страница 38: ...PREOPERATIONAL INSTRUCTIONS 1 To start the dryer a Microprocessor computer dryers 1 The L E D light emitting diode display will read REAdY 2 Press the E on the touchpad of the keyboard 3 The dryer wi...

Страница 39: ...andserialnumbersothatyourinquiryishandledinanexpeditiousmanner B PARTS 1 Replacement parts should be purchased from the distributor from whom the ADC equipment was purchased If the distributor cannot...

Страница 40: ...be contacted or is unknown warranty information can be obtained from the factory by contacting the ADCWarranty Department at 508 678 9000 NOTE Whenever contacting the ADC factory for warranty informa...

Страница 41: ...d in transit Damage claims are the responsibility of the shipper IMPORTANT No replacements credits or refunds will be issued for merchandise damaged in transit 5 ALL returns should be shipped to the A...

Страница 42: ...EACLEAR and FREE FROM COMBUSTIBLE MATERIALS GASOLINE and OTHER FLAMMABLEVAPORS and LIQUIDS NOTE Suggested time intervals shown are for average usage which is considered six 6 to eight 8 operational ru...

Страница 43: ...O NOT OBSTRUCT THE FLOW OF COMBUSTION and VENTILATIONAIR CHECK CUSTOMER FURNISHED BACK DRAFT DAMPERS IN THE EXHAUST DUCTWORK INSPECT and REMOVEANY LINTACCUMULATION WHICH CAN CAUSE THE DAMPER TO BIND o...

Страница 44: ...earing housing for the addition of a grease fitting which can be obtained elsewhere or from ADC by ordering kit Part No 882159 which includes two 2 fittings 2 Impellor fan shaft bearings must be lubri...

Страница 45: ...he drying cycle by pressing any of the preset cycles in letters A F c Verify that the motor s and the heat indicator dots in the microprocessor computer L E D light emitting diode display are on Refer...

Страница 46: ...g Models Only 3 Rev Reverse output L E D indicator for optional Reversing Models Only 4 HT 1 Heat output L E D indicator 5 Fuse Main Fuse input L E D indicator 6 Lint Lint Door input L E D indicator 7...

Страница 47: ...tes within the chosen trial for ignition time 6 seconds the flame sensor detects gas burner flame and signals the Direct Spark Ignition DSI module to keep the gas valve open as long as there is a call...

Страница 48: ...system is functioning properly A flashing green L E D lockout mode indicates that ignition flame has not been confirmed e With the burner flame on remove the flame sensor wire from the sense terminal...

Страница 49: ...ce parts information from American Dryer This information is on the data label located on the inside of the control door When contacting American Dryer please have the model number and serial number a...

Страница 50: ...r particular model 4 TYPE OF HEAT This describes the type of heat for your particular dryer gas either natural gas or liquid propane L P or steam 5 HEAT INPUT for GAS DRYERS This describes the heat in...

Страница 51: ...ill show the applicable error code described above along with an audio indication If the drum temperature is above 100 F 38 C the dryer will continue to run with no heat for three 3 minutes or until t...

Страница 52: ...38 C the dryer will continue to run with no heat for three 3 minutes or until the drum temperature has flattened below 100 F 38 C The clear stop button on the Phase 6 keyboard touchpad must be presse...

Страница 53: ...ADC113143 1 05 01 00 25 2 05 09 00 25 3 05 26 00 50...

Отзывы: